摘    要:介绍离子色谱法测定电厂炉管垢样中腐蚀介质Cl^-和SO4^2-的方法,并对使用在线淋洗液发生器与以前配制淋洗液的方法进行了对比,提出了其在应用中的特性。垢样中Cl^-和SO4^2-的相对标准偏差分别为2.7%和2.3%,回收率分别为89.0%-97.8%和91.0%-98.9%。

关 键 词:离子色谱法 电厂 炉管 垢样 氯离子 硫酸根 测定
修稿时间:2001-12-30

DETERMINATION OF Cl- AND SO42- IN SCALE OF BOILER TUBES IN POWER STATION BY ION CHROMATOGRAPHY
Li Minxian,Gong Qiulin. DETERMINATION OF Cl- AND SO42- IN SCALE OF BOILER TUBES IN POWER STATION BY ION CHROMATOGRAPHY[J]. Chemical Analysis And Meterage, 2002, 11(2): 24-25
Authors:Li Minxian  Gong Qiulin
Abstract:The method for the determination of corrosion medium Cl- and SO42- in scale of boiler tubes in power station by ion chromatography was introduced. The method of on-line device supplying eluent with that of directly confecting duent was compared. Application characteristics of the device were obtained. The RSD of Cl- and SO42- was 2. 7% and 2. 3% , and the recovery was 89.0% -97.8% and 91.0% -98.9% ,respectively.
Keywords:ion chromatography   power station   boiler tube   scale sample   Cl~-    S0_4~(2-)  