Design parameters influencing non-uniform current distributions in superconducting multi-stage stranded cables |
| |
Authors: | Kazutaka Seo Mitsuru Hasegawa Masao Morita Hideto Yoshimura |
| |
Affiliation: | Electromechanical System Department, Advanced Technology R&D Center, Mitsubishi Electric Corporation, 1-1 Tsukaguchi-honmachi 8-chome, Amagasaki, Hyogo, 661 Japan |
| |
Abstract: | We have suggested that non-uniform currents occur due to certain design parameters, for example a combination of cabling pitches, in a previous study. In the present study, we evaluate the occurrences of non-uniform current distributions in terms of design parameters, i.e., the combination of cabling pitches, winding methods (solenoidal and pancake winding) and cross-sectional shape of the cable by numerical analyses. Finally, some basic design concepts to solve this problem are proposed. |
| |
Keywords: | Current distribution Superconducting cable Design parameters |