Polymethacrylate-type monoliths functionalized with chiral amino phosphonic acid-derived strong cation exchange moieties for enantioselective nonaqueous capillary electrochromatography and investigation of the chemical composition of the monolithic polymer
Authors:Preinerstorfer Beatrix  Lindner Wolfgang  Lämmerhofer Michael
Institution:Christian Doppler Laboratory for Molecular Recognition Materials, Institute of Analytical Chemistry, University of Vienna, A-1090 Vienna, Austria.
Abstract:In situ prepared monolithic poly(glycidyl methacrylate-co-ethylene dimethacrylate) (poly(GMA-co-EDMA)) capillary columns were activated to reactive thiol-monoliths and subsequently functionalized with (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutanephosphonic acid as chiral selector by radical addition to afford enantioselective strong cation exchanger (SCX) capillary columns (100 microm inner diameter (ID)). These monolithic capillaries were devised for the enantioseparation of chiral bases by nonaqueous and aqueous capillary electrochromatography (CEC) and the results obtained for mefloquine and its tert-butylcarbamate as test compounds were compared to those obtained with particulate silica-based analogs (packed columns). Despite abolishment of nonspecific ionic interactions between the cationic solutes and residual silanols that may diminish separation factors of the silica-based chiral SCX particles, the poly(GMA-co-EDMA)-supported SCX monolith did not, as expected, show better enantioselectivities, which was assumed to be due to detrimental nonspecific interactions between the analytes and the lipophilic polymer backbone. In order to minimize these unfavorable contributions, less lipophilic monoliths were developed by copolymerization of different amounts of the hydrophilic monomer 2-hydroxyethyl methacrylate (HEMA) with GMA and EDMA, leading to GMA-co-HEMA-co-EDMA-terpolymeric monoliths. By this increase of the hydrophilicity of the monolithic support the enantioselectivity of the resultant SCX stationary phase could be enhanced and reached values comparable to the packed silica-based enantioselective SCX capillaries. Additionally, the mobile phase composition and other variables were examined and it could be shown that the separation factors are considerably affected by diverse parameters such as acetonitrile-methanol ratio and type and concentration of the counterion. Mefloquine enantiomers could be separated with alpha-values up to 1.56 and a maximum plate count of ca. 60,000 m(-1) could be achieved.
Keywords:Chiral selector  Chiral stationary phase  Enantiomer separation  Monolithic column  Nonaqueous capillary electrochromatography
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号