首页 | 本学科首页   官方微博 | 高级检索  
     检索      

强碱阴离子交换树脂及碱性洗脱剂的离子排阻/阴离子交换色谱法同时测定NH4+ ,NO2-和NO3-(英文)
作者姓名:Mori M  Hironaga T  Itabashi H  Nakatani N  Kozaki D  Tanaka K
作者单位:1 Graduate School of Engineering, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma, 376-8515, Japan 2 Rakuno Gakuen University, 582, Midorimachi, Bunkyodai, Ebetsu, Hokkaido 069-8501, Japan 3 Graduate School for International Development and Cooperation, Hiroshima University, 1-5-1, Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8529, Japan
基金项目:supported by Grant-in-Aid for Scientific Research(23615003)in Japan Society for the Promotion of Science(JSPS)
摘    要:Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.

关 键 词:ion-exclusion  chromatography(IEC)  anion-exchange  chromatography(AEC)  inorganic  ions  ammonium  ion  nitrite  ion  nitrate  ion
收稿时间:2011-12-19

Simultaneous determination of NH4+, NO2(-) and NO3(-) by ion-exclusion/anion-exchange chromatography on a strongly basic anion-exchange resin with basic eluent
Mori M,Hironaga T,Itabashi H,Nakatani N,Kozaki D,Tanaka K.Simultaneous determination of NH4+, NO2(-) and NO3(-) by ion-exclusion/anion-exchange chromatography on a strongly basic anion-exchange resin with basic eluent[J].Chinese Journal of Chromatography,2012,30(4):356-360.
Authors:Mori Masanobu  Hironaga Takahiro  Itabashi Hideyuki  Nakatani Nobutake  Kozaki Daisuke  Tanaka Kazuhiko
Institution:1 Graduate School of Engineering, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma, 376-8515, Japan 2 Rakuno Gakuen University, 582, Midorimachi, Bunkyodai, Ebetsu, Hokkaido 069-8501, Japan 3 Graduate School for International Development and Cooperation, Hiroshima University, 1-5-1, Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8529, Japan
Abstract:Ion-exclusion/anion-exchange chromatography (IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH(-)-form with basic eluent has been developed. The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase. This system is useful for simultaneous separation and determination of ammonium ion (NH4+), nitrite ion (NO2(-)), and nitrate ion (NO3(-)) in water samples. The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column. In this study, several separation columns, which consisted of different particle sizes, different functional groups and different anion-exchange capacities, were compared. As the results, the separation column with the smaller anion-exchange capacity (TSKgel Super IC-Anion) showed well-resolved separation of cations and anions. In the optimization of the basic eluent, lithium hydroxide (LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L, considering the resolution of analyte ions and the whole retention times. In the optimal conditions, the relative standard deviations of the peak areas and the retention times of NH4+, NO2(-), and NO3(-) ranged 1.28% - 3.57% and 0.54% - 1.55%, respectively. The limits of detection at signal-to-noise of 3 were 4.10 micromol/L for NH4+, 1.87 micromol/L for NO2(-) and 2.83 micromol/L for NO3(-).
Keywords:ion-exclusion chromatography(IEC)  anion-exchange chromatography(AEC)  inorganic ions  ammonium ion  nitrite ion  nitrate ion
本文献已被 CNKI PubMed 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号