FTIR sensing of inhomogeneous systems using immobilized organometalcarbonyl probe groups
Authors:Creaser C S  Hutchinson W E  Stephenson G R
Institution:Department of Chemistry and Physics, Nottingham Trent University, Clifton Lane, Nottingham, UK NG11 8NS.
Abstract:Tricarbonyl(eta 5-cyclohexadienyl)iron(0) and dicarbonyl(triphenylphosphine)(eta 5-cyclo-hexadienyl)iron(0) were derivatized by attachment of an aminopropylsilyl link and covalently attached to fumed silica particles. The fumed silica was coated onto the ZnSe element of an attenuated total reflection (ATR) cell for Fourier transform infrared (FTIR) spectroscopic analysis. The immobilized organometalcarbonyl probe groups are shown to retain their capacity to function as a key element of a molecular sensor assembly and the nu(CO) bands of the two probe groups were interrogated to calibrate the responses for 0-5% levels of dodecane in cyclohexanol to within +/- 0.1%. The potential for dual sensing is described and the simultaneous monitoring of two discrete regions of a dynamically varying inhomogeneous system is reported for the determination of dodecane in cyclohexanol as solutions mix across a permeable barrier in the ATR cell.