首页 | 本学科首页   官方微博 | 高级检索  
     检索      

带有质量分析系统的强流质子束低能传输线研究
引用本文:黄韬,武启,杨尧,刘建立,方兴,钱程,孙良亭,赵红卫.带有质量分析系统的强流质子束低能传输线研究[J].原子核物理评论,2018,35(1):40-45.
作者姓名:黄韬  武启  杨尧  刘建立  方兴  钱程  孙良亭  赵红卫
作者单位:1.中国科学院近代物理研究所, 兰州 730000;
基金项目:国家重点基础研究发展计划(973计划)项目(2014CB845502);中国科学院科研装备研制项目(28Y531040);国家自然科学基金青年基金项目(11405238)
摘    要:强流质子源与低能传输线(LEBT)是作为CIADS注入器的超导强流质子直线加速器的关键前端系统。目前LEBT采用双螺线管匹配结构设计,并安装有限制锥,但仍然不能避免少量H2+和H3+进入后端加速装置,这对直线加速器长期运行稳定性与可靠性会产生一定影响。为此,在LEBT加入分析磁铁对混合束(H+,H+2,H3+)进行分离再注入后端加速器腔体,将是一个有效的方案。本研究对经过带有30度分析磁铁的LEBT的强流质子束的束流品质进行了模拟与实验测量。结果表明,分析磁铁高阶磁场的影响使经过分析磁铁的强流质子束束流品质变差,并且该影响随着束流包络的增大而增大。这些结果为CIADS注入器的低能传输线设计提供了参考依据。High current proton source and the low energy beam transport(LEBT) are the key front-end systems for CIADS injector:high current proton linac accelerator. CIADS injector's LEBT adopts double solenoid matching structure, using a limit cone which can partially avoid H2+ and H3+ which injecting into the back-end linac accelerator may impact the long-term stability and reliability of the whole system. It will be an effective method to separate the hybrid ions (H+, H2+, H3+) by adding a dipole magnet at LEBT. In this article, we simulated and mesasured the high current proton beam quality behind the LEBT with a 30 degree dipole. The results show that the the proton beam quality is significantly effected by high-order magnetic fields of the dipole magnet, and the effect increases with the increase of the beam envelope. The achieved result is useful for the LEBT design of CIADS injector.

关 键 词:强流质子束    低能传输线    分析磁铁    高阶磁场
收稿时间:2017-04-10

Low Energy Beam Transport of High Current Proton Beam with Quality Analysis System
HUANG Tao,WU Qi,YANG Yao,LIU Jianli,FANG Xing,QIAN Cheng,SUN Liangting,ZHAO Hongwei.Low Energy Beam Transport of High Current Proton Beam with Quality Analysis System[J].Nuclear Physics Review,2018,35(1):40-45.
Authors:HUANG Tao  WU Qi  YANG Yao  LIU Jianli  FANG Xing  QIAN Cheng  SUN Liangting  ZHAO Hongwei
Institution:1.Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;2.University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:High current proton source and the low energy beam transport(LEBT) are the key front-end systems for CIADS injector:high current proton linac accelerator. CIADS injector's LEBT adopts double solenoid matching structure, using a limit cone which can partially avoid H2+ and H3+ which injecting into the back-end linac accelerator may impact the long-term stability and reliability of the whole system. It will be an effective method to separate the hybrid ions (H+, H2+, H3+) by adding a dipole magnet at LEBT. In this article, we simulated and mesasured the high current proton beam quality behind the LEBT with a 30 degree dipole. The results show that the the proton beam quality is significantly effected by high-order magnetic fields of the dipole magnet, and the effect increases with the increase of the beam envelope. The achieved result is useful for the LEBT design of CIADS injector.
Keywords:high current proton beam  LEBT  dipole magnet  high order magnetic field
本文献已被 CNKI 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号