Applying INAA to the homogeneity study of a Perna perna mussel reference material |
| |
Authors: | E. G. Moreira M. B. A. Vasconcellos M. G. M. Catharino V. A. Maihara M. Saiki |
| |
Affiliation: | 1.Instituto de Pesquisas Energéticas e Nucleares (IPEN)—CNEN/SP,S?o Paulo,Brazil |
| |
Abstract: | Instrumental neutron activation analysis (INAA) was used in the homogeneity study of a Perna perna (Linnaeus 1758) mussel reference material. Simultaneous determination of 15 elements in six bottles of the material, from a total of 171, was performed. The bottles were considered homogeneous for the analyzed elements, at the 95% confidence level, according to the analysis of variance test performed. Elements were also determined in one bottle with five different sample masses for minimum sample intake estimation. Results varied from 50 to 350 mg, depending on the element. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|