首页 | 本学科首页   官方微博 | 高级检索  
     


Trace analysis of residual methyl methanesulfonate, ethyl methanesulfonate and isopropyl methanesulfonate in pharmaceuticals by capillary gas chromatography with flame ionization detection
Authors:Li Weiyong
Affiliation:Global Analytical Development, Johnson and Johnson Pharmaceutical Research and Development, LLC, Raritan, NJ 08869, USA. wli1@prdus.jnj.com
Abstract:A capillary gas chromatographic method using flame ionization detection was developed and validated for the trace analysis (ppm level) of methyl methanesulfonate, ethyl methanesulfonate, and isopropyl methanesulfonate in pharmaceutical drug substance. The method utilizes a megabore capillary column with bonded and crosslinked polyethylene glycol stationary phase. A dissolve-and-injection approach was adopted for sample introduction in a splitless mode. The investigated sample solvents include acetonitrile, ethyl acetate, methylene chloride, 1,2-dichloromethane, and toluene. Aqueous mixtures of acetonitrile and water can also be used as sample solvent. A limit of detection of about 1 microg/g (1 ppm) and limit of quantitation of 5 microg/g (5 ppm) were achieved for the mesylate esters in drug substance samples. The method optimization and validation are also discussed in this paper.
Keywords:
本文献已被 PubMed 等数据库收录!