Gas–liquid pressure drop in vertical internally wavy 90° bend
Authors:Shannak Benbella  Mohammad Al-Shannag  Zaid A. Al-Anber
Affiliation:1. Department of Mechanical Engineering, Al-Balqa Applied University, Al-Huson University College, P.O. Box 50, Al-Huson, Jordan;2. Department of Chemical Engineering, Faculty of Engineering Technology, Al-Balqa Applied University, P.O. Box 15008, Marka 11134, Amman, Jordan
Abstract:Experiments of air water two-phase flow pressure drop in vertical internally wavy 90° bend have been carried out. The tested bends are flexible and made of stainless steel with inner diameter of 50 mm and various curvature radiuses of 200, 300, 400 and 500 mm. The experiments were performed under the following conditions of two-phase parameters; mass flux from 350 to 750 kg/m2 s. Gas quality from 1% to 50% and system pressure from 4 to 7.5 bar. The results demonstrate that the effect of the above-mentioned parameters is very significant at high ranges of mass flow quality. Due to the increasing of two-phase flow resistance, energy dissipations, friction losses and interaction of the two-phases in the vertical internally wavy 90° bend the total pressure drops are perceptible about 2–5 times grater than that in smooth bends. Based on the mass and energy balance as well as the presented experimental results, new empirical correlation has been developed to calculate the two-phase pressure drop and hence the two-phase friction factor of the tested bends. The correlation includes the relevant primary parameter, fit the data well, and is sufficiency accurate for engineering purposes.