首页 | 本学科首页   官方微博 | 高级检索  
     

Novel colorimetric sensor for mercury (Ⅱ) based on layer-by-layer assembly of unmodified silver triangular nanoplates
引用本文:Ekarat Detsri. Novel colorimetric sensor for mercury (Ⅱ) based on layer-by-layer assembly of unmodified silver triangular nanoplates[J]. 中国化学快报, 2016, 27(10): 1635-1640. DOI: 10.1016/j.cclet.2016.05.008
作者姓名:Ekarat Detsri
作者单位:a Department of Chemistry, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand;b Advanced Materials Research Unit, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand
基金项目:This work was supported by Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand (No. 2559-01-05-033).
摘    要:A simple layer-by-layer deposition technique was used to fabricate the multilayer thin films of unmodified silver triangular nanoplates(AgTNPs).The multilayer of AgTNPs thin films were fabricated by alternate deposition of each anionic sodium citrate stabilized AgTNPs and cationic poly(diallyldimethylammonium chloride).All prepared AgTNPs multilayer thin films were exhibited a strong plasmon band at the wavelength of 667 nm,which confirmed the formation of AgTNPs onto the substrate.The characteristics of the multilayer thin films were investigated using contact angle measurement,UV-visible spectroscopy,X-ray diffraction analysis(XRD),atomic force microscope(AFM)and field emission scanning electron microscope(FESEM).As these films are to be used as a mercury(II)colorimetric sensor,the changes in optical properties of the films were evaluated for various mercury(Ⅱ)concentrations.AgTNPs assembled into thin films showed a strong color shift from blue to mauve and colorless when exposed to mercury(Ⅱ).The constructed multilayer thin films exhibited excellent color changes of mercury(II) with a linear range between 0.5 and 20 ppm.The limit of detection(LOD) and limit of quantitation(LOQ) were 0.45 ± 0.002 and 1.52 ± 0.002 ppm,respectively.The recovery values of AgTNPs multilayer thin films are satisfactory in the range of 100.1%-106.4%when applied to determining mercury(Ⅱ) in water samples.


Novel colorimetric sensor for mercury (II) based on layer-by-layer assembly of unmodified silver triangular nanoplates
Ekarat Detsri. Novel colorimetric sensor for mercury (II) based on layer-by-layer assembly of unmodified silver triangular nanoplates[J]. Chinese Chemical Letters, 2016, 27(10): 1635-1640. DOI: 10.1016/j.cclet.2016.05.008
Authors:Ekarat Detsri
Affiliation:a Department of Chemistry, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand;b Advanced Materials Research Unit, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand
Abstract:A simple layer-by-layer deposition technique was used to fabricate the multilayer thin films of unmodified silver triangular nanoplates (AgTNPs). The multilayer of AgTNPs thin films were fabricated by alternate deposition of each anionic sodium citrate stabilized AgTNPs and cationic poly(diallyldimethylammonium chloride). All prepared AgTNPs multilayer thin films were exhibited a strong plasmon band at the wavelength of 667 nm, which confirmed the formation of AgTNPs onto the substrate. The characteristics of the multilayer thin films were investigated using contact angle measurement, UV-visible spectroscopy, X-ray diffraction analysis (XRD), atomic force microscope (AFM) and field emission scanning electron microscope (FESEM). As these films are to be used as a mercury (Ⅱ) colorimetric sensor, the changes in optical properties of the films were evaluated for various mercury (Ⅱ) concentrations. AgTNPs assembled into thin films showed a strong color shift from blue to mauve and colorless when exposed to mercury (Ⅱ). The constructed multilayer thin films exhibited excellent color changes of mercury (Ⅱ) with a linear range between 0.5 and 20 ppm. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.45 0.002 and 1.52 0.002 ppm, respectively. The recovery values of AgTNPs multilayer thin films are satisfactory in the range of 100.1%-106.4% when applied to determining mercury (Ⅱ) in water samples.
Keywords:Silver triangular nanoplates  Layer-by-Layer  Mercury (II)  Colorimetric sensor  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国化学快报》浏览原始摘要信息
点击此处可从《中国化学快报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号