首页 | 本学科首页   官方微博 | 高级检索  
     


A quantitative LC/MS method targeting urinary 1-methyl-4-imidazoleacetic acid for safety monitoring of the global histamine turnover in clinical studies
Authors:J. Kolmert  B. Forngren  J. Lindberg  J. Öhd  K. M. Åberg  G. Nilsson  T. Moritz  A. Nordström
Affiliation:1. Department of Molecular Biology, Ume? University, 901 87, Ume?, Sweden
2. Ume? Plant Science Center, Department of Forest Genetics and Plant Physiology, Swedish University of Agricultural Sciences, 901 83, Ume?, Sweden
3. Global Safety Assessment, AstraZeneca R&D, 151 85, S?dert?lje, Sweden
5. Department of Analytical Chemistry, Stockholm University, 106 91, Stockholm, Sweden
7. Cobra Biologics AB, 152 57, S?dert?lje, Sweden
8. Analytical Proof Sweden AB, 115 37, Stockholm, Sweden
4. Global Medicines Development, AstraZeneca R&D, 151 85, S?dert?lje, Sweden
9. Shire AG, 1262, Eysins, Switzerland
6. Department of Medicine, Clinical Immunology and Allergy, Karolinska Institutet, 171 76, Stockholm, Sweden
Abstract:Anaphylaxis is a potentially life-threatening condition triggered mainly by the release of inflammatory mediators, notably histamine. In pharmaceutical research, drug discovery, and clinical evaluation, it may be necessary to accurately assess the potential of a compound, event, or disorder to promote the release of histamine. In contrast to the measurement of plasma histamine, determination of the stable metabolite 1-methyl-4-imidazoleacetic acid (tele-MIAA) in urine provides a noninvasive and more reliable methodology to monitor histamine release. This study presents a repeatable high-performance liquid chromatography coupled to electrospray mass spectrometry (LC–ESI–MS) method where tele-MIAA is baseline separated from its structural isomer 1-methyl-5-imidazoleacetic acid (pi-MIAA) and an unknown in human urine. The ion-pairing chromatography method, in reversed-phase mode, based on 0.5 mM tridecafluoroheptanoic acid demonstrated high repeatability and was applied in a clinical development program that comprised a large number of clinical samples from different cohorts. The inter- and intra-run precision of the method for tele-MIAA were 8.4 and 4.3 %, respectively, at the mean urinary concentration level, while method accuracy was between ?16.2 and 8.0 % across the linear concentration range of 22–1,111 ng mL?1. Overall, method precision was greater than that reported in previously published methods and enabled the identification of gender differences that were independent of age or demography. The median concentration measured in female subjects was 3.0 μmol mmol?1 of creatinine, and for male subjects, it was 2.1 μmol mmol?1 of creatinine. The results demonstrate that the method provides unprecedented accuracy, precision, and practicality for the measurement of tele-MIAA in large clinical settings.
Figure
Assessment of global histamine turnover by means of urinary tele-MIAA determination
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号