首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A New Sensor for Simultaneous Determination of Tyrosine and Dopamine Using Iron(III) Doped Zeolite Modified Carbon Paste Electrode
Authors:Ali Babaei  Mojgan Zendehdel  Balal Khalilzadeh  Mohammad Abnosi
Abstract:A new chemically modified electrode is constructed based on iron(III) doped zeolite modified carbon paste electrode (Fe3+Y/ZMCPE). The new sensor could be used for the simultaneous determination of the biologically important compounds dopamine (DA) and tyrosine (Tyr). The measurements are carried out using differential pulse voltammetric (DPV) method. The prepared modified electrode shows voltammetric responses of high sensitivity, selectivity and stability for DA and Tyr under optimal conditions, which makes it a suitable sensor for simultaneous trace detection of DA and Tyr in solution. Application of the DPV method demonstrates that in the Briton Robinson buffer solutions (pH=5) containing 50 µmol/L Tyr, there is a linear relationship between the oxidation peaks and the concentrations of DA over the range of 0.1–200 µmol/L, with a detection limit of 0.05 µmol/L (S/N=3). For Tyr a linear correlation between oxidation peak current and concentration of Tyr over the range of 0.5–200 µmol/L (containing 50 µmol/L DA), with a detection limit of 0.08 µmol/L is obtained. The analytical performances of this sensor are evaluated for the detection of DA and Tyr in human serum and a medicine.
Keywords:carbon paste electrode  modified electrode  iron(III) doped zeolite  dopamine  tyrosine
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号