全文获取类型
收费全文 | 89篇 |
免费 | 11篇 |
国内免费 | 3篇 |
专业分类
化学 | 5篇 |
力学 | 4篇 |
综合类 | 1篇 |
物理学 | 34篇 |
无线电 | 59篇 |
出版年
2022年 | 1篇 |
2021年 | 2篇 |
2020年 | 4篇 |
2019年 | 1篇 |
2018年 | 3篇 |
2016年 | 4篇 |
2015年 | 5篇 |
2014年 | 6篇 |
2013年 | 10篇 |
2012年 | 5篇 |
2011年 | 9篇 |
2010年 | 3篇 |
2009年 | 2篇 |
2008年 | 12篇 |
2007年 | 4篇 |
2006年 | 4篇 |
2005年 | 3篇 |
2004年 | 2篇 |
2003年 | 7篇 |
2002年 | 3篇 |
2001年 | 1篇 |
2000年 | 2篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1997年 | 3篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1994年 | 2篇 |
排序方式: 共有103条查询结果,搜索用时 62 毫秒
1.
V. A. Drebushchak 《Journal of Thermal Analysis and Calorimetry》2005,79(1):213-218
One-point (Mettler) and many-point (Netzsch) heat flow calibration of a DSC is discussed. It is shown that the two types of calibration are the alternative extremes between quick but rough procedure and time-consuming but accurate one. One-point calibration compares a typical function k(T) at the melting point of indium with the measured value for particular DSC and multiplies k(T) by a scaling factor. Many-point calibration is based on general mathematical procedure, namely fitting a set of experimental values of sensitivity to a polynomial. The polynomial coefficients are evaluated by the method of least squares. Based on the relationship between the sensitivity of a thermocouple and calibration coefficient of a DSC sensor made from it, two-point heat flow calibration is suggested. This is an optimal calibration procedure, for the relationship contains only two unknown coefficients. An example of how to perform the two-point calibration with Netzsch-Proteus Software is described in the Appendix. 相似文献
2.
为实现空腔爆炸温度、压力变化趋势的准确测量,基于铠装K型热电偶和压力变送器,建立密闭空腔爆后气体温度、压力测量系统。设计密封隔热防护装置,将传感器的敏感端与信号调理模块分别安装在两个密封腔内,有效提高了传感器在大当量爆炸冲击条件下的存活率。在0.86m/kg1/3比距离密闭空腔大当量爆炸条件下,对传感器及防护装置的性能进行考核验证,爆后测量采集到了有效的气体温度及压力变化历程,且传感器状态能够最终恢复至正常状态。测试结果表明,使用密封隔热安装的K型热电偶和压力变送器可以满足小比距离密闭空腔爆后气体静态温度、压力测量需求。 相似文献
3.
4.
5.
运用电学的基本原理,对数显温控高温炉的故障进行了分析,在实践中总结出各种故障的发生原因、特征现象及解决方法。 相似文献
6.
A. Schneuwly P. Gröning L. Schlapbach G. Müller 《Journal of Electronic Materials》1998,27(11):1254-1261
To reduce cost and enhance reliability for microelectronics applications, a complete understanding of the thermosonic bonding
process is required. In particular, the question of whether melting, diffusion, or significant heating occurs along the interface
during friction has often been raised. We present results obtained with a new device based on thermoelectric temperature measurements
to determine the temperature at the bond interface. In addition to the temperature information, the data characterizes the
bonding process in real time on a micrometer scale. The basic principle of the developed apparatus is temperature measurement
by an Au-Ni thermocouple fixed within the inside chamfer of a bonding capillary. Different bond substrates with high and low
bond contact quality have been investigated. The thermoelectric temperature measurements very precisely determines the bonding
behavior of the bond pads. A few nanometers surface contamination on a bond pad significantly reduces the temperature rise
at the bond interface and therefore impairs bondability of the substrate. These results demonstrate the sensitivity and accuracy
of the measurement principle. The apparatus is a powerful tool to measure the tribology of the bond system and to characterize
the bondability of different bond pads. 相似文献
7.
8.
9.
电阻炉温度的检测和控制直接与能耗、生产效率、产品质量、安全生产等重大技术指标相关联.为了能快速、准确检测与控制电阻炉的温度,系统采用K型热电偶和MAX6675作为温度采集模块,以单片机SI℃89C52为核心,设计了一种基于K型热电偶电阻炉温度检测控制系统,包括系统的硬件电路与软件系统.经实验测试,系统控制精度达到0.5℃,且性能稳定,使用简便,符合设计的预期要求. 相似文献
10.
用高温应变计和热偶计等诊断技术,研究连续波氧碘化学激光(CW/COIL)与铝合金板作用产生的激光热应力。当照射靶面激光强度约1 000 W/cm2时,激光热应力随靶厚的增加而快速减小。当激光辐照靶材厚度h=1.00 mm、激光强度I=640~980 W/cm2时,激光热应力随辐照靶面激光强度的增加而增大。两者的激光热应力-时间曲线随靶厚的减薄或随辐照靶面激光强度的增加而变得越来越复杂。当靶厚h≤2.50 mm,辐照靶面激光强度I≥800 W/cm2时,激光热应力强度超过激光辐照区材料断裂强度,萌生许多孔洞裂纹,引起材料断裂破坏。 相似文献