首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  免费   1篇
  国内免费   1篇
物理学   2篇
  2017年   1篇
  2012年   1篇
排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
Active spot-scanning test with heavy ions at HIRFL-CSR   总被引:1,自引:0,他引:1  
An active spot beam delivery system for heavy ion therapy has been developed based on the Cooling Storage Ring at HIRFL-CSR, where the pencil carbon-ion beams were scanned within a target volume transversely by a pair of orthogonal (horizontal and vertical) dipole magnets to paint the slices of the target volume and longitudinally by active energy variation of the synchrotron slice by slice. The unique techniques such as dose shaping via active energy variation and magnetic deflection constitute a promising three-dimensional conformal even intensity-modulated radiotherapy with heavy ions at HIRFL-CSR. In this paper, the verification of active energy variation and the calibration of steerable beam deflection are shown, as the basic functionality components of the active spot-scanning system. Additionally, based on the capability of creating homogeneous irradiation fields with steerable pencil beams, a radiobiological experiment like cell survival measurement has been performed aiming at comparison of the radiobiological effects under active and passive beam deliveries.  相似文献   
2.
The three-dimensional(3D) spot-scanning method is one of the most commonly used irradiation methods in charged particle beam radiotherapy.Generally,spot-scanning beam delivery utilizes the same size pencil beam to irradiate the tumor targets.Here we propose a spot-scanning beam delivery method with laterally-and longitudinallymixed size pencil beams for heavy ion radiotherapy.This uses pencil beams with a bigger spot size in the lateral direction and wider mini spread-out Bragg peak(mini-SOBP) to irradiate the inner part of a target volume,and pencil beams with a smaller spot size in the lateral direction and narrower mini-SOBP to irradiate the peripheral part of the target volume.Instead of being controlled by the accelerator,the lateral size of the pencil beam was adjusted by inserting Ta scatterers in the beam delivery line.The longitudinal size of the pencil beam(i.e.the width of the mini-SOBP) was adjusted by tilting mini ridge filters along the beam direction.The new spot-scanning beam delivery using carbon ions was investigated theoretically and compared with traditional spot-scanning beam delivery.Our results show that the new spot-scanning beam delivery has smaller lateral penumbra,steeper distal dose fall-off and the dose homogeneity(1-standard deviation/mean) in the target volume is better than 95%.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号