首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   56篇
  免费   2篇
  国内免费   1篇
化学   15篇
力学   2篇
数学   8篇
物理学   34篇
  2021年   1篇
  2016年   4篇
  2014年   2篇
  2013年   4篇
  2012年   2篇
  2011年   2篇
  2010年   4篇
  2009年   8篇
  2008年   4篇
  2007年   3篇
  2006年   7篇
  2005年   5篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
  1999年   5篇
  1998年   1篇
  1997年   1篇
  1991年   1篇
  1988年   1篇
  1982年   1篇
排序方式: 共有59条查询结果,搜索用时 692 毫秒
1.
This work describes the syntheses of a new poly(amidoamine) (PAMAM) dendrimer family possessing a disulfide function (cystamine) in its core. Traditional redox-chemistry associated with the disulfide core in these dendrimer structures, provides a versatile strategy for designing unique sizes, shapes and controlling the regio-disposition of chemical groups on the surface of these dendrimers. Various single site, sulfhydryl functionalized dendron reactants may be generated in situ, under standard reducing conditions (i.e. dithiothreitol (DTT)). Facile control of size, shape and chemical functionality placement involves covalent hybridization of these single point, sulfhydryl reactive dendron components. This is accomplished by re-oxidation in the presence of air, to yield generation/surface chemistry differentiated cross-over products which may be isolated by preparative thin layer or column chromatography. Differentiated cystamine core dendrimers derived from combination and permutation of lower generation (i.e. Gen.=0-3) sulfhydryl functionalized dendrons possessing amino, hydroxyl, acetamido or dansyl surface groups, were synthesized and isolated. They were characterized by a variety of methods including; 13C NMR, capillary electrophoresis (CE), gel electrophoresis (PAGE), thin layer chromatography (TLC) and electrospray (ES) or matrix assisted laser desorption ionization (MALDI-TOF) mass spectrometry. This general strategy has broad implications for the systematic size, shape and regio-chemical control of a wide range of dendritic nanostructures, many of which may be designed to mimic the sizes, shapes and regio specific chemo-domains observed for globular proteins.  相似文献   
2.
蒋晟  吴毓林  姚祝军 《中国化学》2002,20(11):1393-1400
IntroductionInthepasttwodecades ,alargefamilyofnaturalproductsnamedannonaceousacetogeninswereisolatedandcharacterizedbytheglobalresearchersfromvariousspeciesoftheplantannonaeae .1Amongover 4 0 0mem bers,mostofthemwerefoundtoshowpotentcytotoxicandantitumora…  相似文献   
3.
The carbon-13 chemical shifts of seven N-(4-substituted phenyl) piperidine; the corresponding N-oxides, and their thermal rearrangement products were analyzed and assigned. The N-oxidation effect on the carbon-13 chemical shift is discussed, a correlation of N-oxidation effect with substituent constant (σp, σm, σI and σR) has been studied; dual substituent-parameter equation produce better correlation.  相似文献   
4.
ObjectivePurpose of the study is to verify the Gamma Knife Extend™ system (ES) based fractionated stereotactic radiosurgery with newly developed head-thorax phantom.MethodsPhantoms are extensively used to measure radiation dose and verify treatment plan in radiotherapy. A human upper body shaped phantom with thorax was designed to simulate fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife. The central component of the phantom aids in performing radiological precision test, dosimetric evaluation and treatment verification. A hollow right circular cylindrical space of diameter 7.0 cm was created at the centre of this component to place various dosimetric devices using suitable adaptors. The phantom is made of poly methyl methacrylate (PMMA), a transparent thermoplastic material. Two sets of disk assemblies were designed to place dosimetric films in (1) horizontal (xy) and (2) vertical (xz) planes. Specific cylindrical adaptors were designed to place thimble ionization chamber inside phantom for point dose recording along xz axis. EBT3 Gafchromic films were used to analyze and map radiation field. The focal precision test was performed using 4 mm collimator shot in phantom to check radiological accuracy of treatment. The phantom head position within the Extend™ frame was estimated using encoded aperture measurement of repositioning check tool (RCT). For treatment verification, the phantom with inserts for film and ion chamber was scanned in reference treatment position using X-ray computed tomography (CT) machine and acquired stereotactic images were transferred into Leksell Gammaplan (LGP). A patient treatment plan with hypo-fractionated regimen was delivered and identical fractions were compared using EBT3 films and in-house MATLAB codes.ResultsRCT measurement showed an overall positional accuracy of 0.265 mm (range 0.223 mm–0.343 mm). Gamma index analysis across fractions exhibited close agreement between LGP and film measured dose with ≥90% (max 93%) pixel pass rate at 1 mm of spatial and 1% of dosimetric tolerances. The focal precision test showed the variation of 0.465 mm between radiological and planned iso-centre.ConclusionsThe study demonstrated the suitability of newly developed head-thorax phantom for dosimetric verification of fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife.  相似文献   
5.
The paper presents a theoretical and experimental study of vibrating structures where paramagnetic or diamagnetic systems interact with rare-earth passive magnets.The theoretical model of the system is focused on the damping properties of permanent magnets and on their interactions with the dynamic behaviour of an Euler–Bernoulli beam. In particular, the magnetic model is based on the analogy of the equivalent currents method in a quasi-static open-circuit-type configuration and it is used to determine the influence of eddy currents on the dynamic behaviour of conducting material structures. The magnetic effects are characterised by a viscous-type damping and by a stiffening dynamic effect of the structure, called “phantom effect”.The authors present the experimental outcomes for uniform cantilever clamped-free beams of different kinds of paramagnetic or diamagnetic conducting materials. It appears that the system frequency response can be modified by the presence of a pair of concordant or discordant permanent magnets of high residual induction settled at the free end.Through the comparison between theoretical and experimental results, the paper demonstrates the validity of the model, that is able to describe both the above mentioned effect of dynamic stiffening of the structure and the considerable localised damping properties in paramagnetic or diamagnetic materials having low electric resistivity.  相似文献   
6.
Measurements of the magnetic field dependence of spin-lattice relaxation rates and the response of the water-proton signal intensity to off-resonance radio frequency fields show that the commonly used agarose phantom provides a less faithful representation for the magnetic response of tissue than does a cross-linked protein system. The origin of these differences lies in the structure and intramolecular dynamics of the macromolecular system used to make the gel. These distinctions will also cause differences in the magnetic response of the water spin system when paramagnetic relaxation agents or contrast agents are incorporated. Use of a thermally cross-linked bovine serum albumin phantom is suggested.  相似文献   
7.
8.
In this study, controlled amount of dangling ends is introduced to the two series of poly(ethylene glycol)‐based hydrogel networks with three and four crosslinking functionality by using click chemistry. The structure of the gels with regulated defect percentage is confirmed by comparing the results of low‐field NMR characterization and Monte Carlo simulation. The mechanical properties of these gels were characterized by tensile stress–strain behaviors of the gels, and the results are analyzed by Gent model and Mooney–Rivlin model. The shear modulus of the swollen gels is found to be dependent on the functionality of the network, and decreases with the defect percentage. Furthermore, the value of shear modulus well obeys the Phantom model for all the gels with varied percentage of the defects. The maximum extension ratio, obtained from the fitting of Gent model, is also found to be dependent on the functionality of the network, and does not change with the defect percentage, except at very high defect percentage. The value of the maximum extension ratio is between that predicted from Phantom model and the Affine model. This indicates that at the large deformation, the fluctuation of the crosslinking points is suppressed for some extend but still exists. Polymer volume fractions at various defect percentages obtained from prediction of Flory–Rehner model are found to be in well agreement with the swelling experiment. All these results indicate that click chemistry is a powerful method to regulate the network structure and mechanical properties of the gels. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016 , 54, 1227–1236  相似文献   
9.
Magnetic field has been applied to a copper vapor laser with an intention of improving the laser characteristics by inner gas convection. The convection induced by the J×B cross-field discharge (the Lorentz force) is used for partially replacing or mixing the laser medium in a highly heated discharged region with relatively cold gas surrounding the region. It is observed that the output power increases with the increase of the magnetic field. A 23% increase in the output power is obtained with a magnetic field of 150 gauss. The cross-field discharge causes an increase in the peak discharge voltage and a reduction in the initial part of discharge current (Phantom current). Based on the results observed, the possible mechanisms for increasing the power are discussed.  相似文献   
10.
The effect of susceptibility differences between fluid and fibers on the properties of DTI fiber phantoms was investigated. Thereto, machine-made, easily producible and inexpensive DTI fiber phantoms were constructed by winding polyamide fibers of 15 microm diameter around a circular acrylic glass spindle. The achieved fractional anisotropy was 0.78+/-0.02. It is shown by phantom measurements and Monte Carlo simulations that the transversal relaxation time T(2) strongly depends on the angle between the fibers and the B(0) field if the susceptibilities of the fibers and fluid are not identical. In the phantoms, the measured T(2) time at 3 T decreased by 60% for fibers running perpendicular to B(0). Monte Carlo simulations confirmed this result and revealed that the exact relaxation time depends strongly on the exact packing of the fibers. In the phantoms, the measured diffusion was independent of fiber orientation. Monte Carlo simulations revealed that the measured diffusion strongly depends on the exact fiber packing and that field strength and -orientation dependencies of measured diffusion may be minimal for hexagonal packing while the diffusion can be underestimated by more than 50% for cubic packing at 3 T. To overcome these effects, the susceptibilities of fibers and fluid were matched using an aqueous sodium chloride solution (83 g NaCl per kilogram of water). This enables an orientation independent and reliable use of DTI phantoms for evaluation purposes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号