首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   94篇
  免费   1篇
化学   71篇
物理学   24篇
  2023年   2篇
  2022年   5篇
  2021年   2篇
  2020年   1篇
  2019年   1篇
  2016年   1篇
  2015年   3篇
  2014年   2篇
  2013年   6篇
  2012年   9篇
  2011年   8篇
  2010年   5篇
  2009年   11篇
  2008年   2篇
  2007年   4篇
  2006年   6篇
  2005年   5篇
  2004年   5篇
  2003年   4篇
  2002年   2篇
  2001年   1篇
  2000年   3篇
  1999年   1篇
  1998年   4篇
  1996年   1篇
  1987年   1篇
排序方式: 共有95条查询结果,搜索用时 15 毫秒
1.
We present developments in dynamic magnetic resonance imaging that allow internal structural muscle markers to be followed during heating. This monitoring is based on quantitative characterization of the experimental conditions and their temperature time course. A nonlinear image registration technique was optimized and applied to consecutively acquired images to measure the deformation fields in the muscle. A model coupling local deformation and temperature was obtained, which for the first time takes into account the variations of deformation and temperature in the sample. This modeling opens the way to a better understanding of the mechanisms responsible for mass loss and degradation of the textural properties of muscle during heating.  相似文献   
2.
An ELISA was developed for routine examination for extensive monitoring and screening programs for the residues of salbutamol in swine serum, animal feed, meat, and meat-related products destined for human consumption in Taiwan. Objectives of the study were to investigate the use of a new immunoassay for the detection of salbutamol residues in swine meat and animal feed samples, and to compare with a commercial kit in field test screens. A fast, simple and reliable sample preparation method for the determination of salbutamol was established. Field trials with 222 swine meat and 120 animal feed samples that were taken from local meat markets, auction markets and feed mills. The application and the results of two ELISA kits (a homemade and a commercial kit) for the screening of salbutamol were presented. Adopting 2 μg kg−1 salbutamol as a cut-off value for swine meat, the commercial β-agonist ELISA had a sensitivity of 85.3% and a specificity of 95.2% versus GC-MS at a cut-off of 2 μg kg−1. The homemade salbutamol ELISA had a sensitivity of 100% and a specificity of 90.9% and gave no false-negative rate results. Furthermore, adopting 20 μg kg−1 salbutamol as a cut-off value for animal feed, both the commercial and homemade ELISA showed 100% sensitivity and 100% specificity of the assays. In conclusion, a sensitive, specific salbutamol polyclonal antibody-based ELISA has been developed that could serve as a rapid screening assay, and the detection of positive samples at the place of sampling can result in more effective control of the illegal use of β-agonists.  相似文献   
3.
A multiresidue method was described for determining eight sulfonamides, SAs (sulfadiazine, sulfamerazine, sulfamethoxypyridazine, sulfachloropyridazine, sulfadoxine, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline) in animal muscle tissues (pork, chicken, turkey, lamb and beef) at concentrations below the maximum residue limit (100 μg kg−1) set by the European Commission. The method was based on the microextraction of SAs in 300-mg muscle samples with 1 mL of a supramolecular solvent made up of reverse micelles of decanoic acid (DeA) and posterior determination of SAs in the extract by LC/fluorescence detection, after in situ derivatization with fluorescamine. Recoveries were quantitative (98–109%) and matrix-independent, no concentration of the extracts was required, the microextraction took about 30 min and several samples could be simultaneously treated. Formation of multiple hydrogen bonds between the carboxylic groups of the solvent and the target SAs (hydrogen donor and acceptor sum between 9 and 11) were considered as the major forces driving microextraction. The method was validated according to the European Union regulation 2002/657/EC. Analytical performance in terms of linearity, selectivity, trueness, precision, stability of SAs, decision limit and detection capability were determined. Quantitation limits for the different SAs ranged between 12 μg kg−1 and 44 μg kg−1, they being nearly independent of matrix composition. Repeatability and reproducibility, expressed as relative standard deviation, were in the ranges 1.8–3.6% and 3.3–6.1%. The results of the validation process proved that the method is suitable for determining sulfonamide residues in surveillance programs.  相似文献   
4.
N-nitrosamines are meant to be probable or possible carcinogenic components, possibly formed out of a reaction between nitrite and N-containing substances such as amino acids and secondary amines. Nitrite is often used for processing meat products because of its colouring and antimicrobial properties.During this experimental setup, the influence of proline, hydroxyproline or pyrrolidine on N-nitrosamine formation in meat samples was evaluated. The N-nitrosamines concentrations were measured with gas chromatography-thermal energy analyzer. Only the concentrations of N-nitrosodimethylamine and N-nitrosopyrrolidine were found above the limit of detection in a number of tested experimental conditions. The concentration of these two N-nitrosamines was modelled as a function of temperature and nitrite concentration for different situations (presence or absence of added natural N-containing meat components). It could be concluded that proline and pyrrolidine promoted the formation of N-nitrosopyrrolidine. It could also be confirmed that the higher the temperature of the meat processing procedure and the higher the sodium nitrite amounts added, the higher were the yields of the respective N-nitrosamines.  相似文献   
5.
6.
The availability of robust methods for the species-specific detection of meat and bone meal (MBM) in compound feedingstuffs is an important prerequisite to enforce current and upcoming European legislation on the use of processed animal proteins in animal nutrition. Among possible methods, those based on DNA turned out to be a reliable tool for this aim, since DNA is a quite thermostable molecule able to resist severe heat treatments applied in the manufacturing of animal meals. The application of such methods by control laboratories implies that the method has been validated including an assessment of its robustness. Successful transferability between laboratories is considered an important robustness criterion of the method. However, corresponding guidelines regarding the design of such a study relevant to this field are missing. Here, we demonstrate the feasibility of an alternative concept that was applied to check for the transferability of a qualitative assay for the detection of banned MBM in feedingstuffs at trace level based on real-time PCR. The concept was based on an experimental nested design applying analysis of variance (ANOVA) that was conducted independently in two laboratories and which allows for establishing major factors influencing the result of analysis. Statistical assessment of the results confirmed the importance of the DNA extraction/purification step utilised, whereas the PCR step turned out to be a minor factor regarding the overall variability of the results. Furthermore, blind samples comprised of compound feed adulterated with MBM at 0.1 % and blank compound feed were correctly classified as "positive" or "negative" samples, thus confirming fitness of purpose for the method. This approach can be of interest for other research groups working in the development of real-time PCR methods and in their use by control laboratories. Nested design of the study to check for the transferability of the real-time PCR method  相似文献   
7.
Microwave-assisted extraction (MAE) and dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) were evaluated for use in the extraction and preconcentration of volatile nitrosamines in meat products. Parameters affecting MAE, such as the extraction solvent used, and DLLME, including the nature and volume of the extracting and disperser solvents, extraction time, salt addition and centrifugation time, were optimized. In the MAE method, 0.25g of sample mass was extracted in 10mL NaOH (0.05M) in a closed-vessel system. For DLLME, 1.5mL of methanol (disperser solvent) containing 20μL of carbon tetrachloride (extraction solvent) was rapidly injected by syringe into 5mL of the sample extract solution (previously adjusted to pH 6), thereby forming a cloudy solution. Phase separation was performed by centrifugation, and a volume of 3μL of the sedimented phase was analyzed by GC-MS. The enrichment factors provided by DLLME varied from 220 to 342 for N-nitrosodiethylamine and N-nitrosopiperidine, respectively. The matrix effect was evaluated for different samples, and it was concluded that sample quantification can be carried out by aqueous calibration. Under the optimized conditions, detection limits ranged from 0.003 to 0.014ngmL(-1) for NPIP and NMEA, respectively (0.12-0.56ngg(-1) in the meat products).  相似文献   
8.
A method of estimating Al leaching from Al cook ware in some meat extracts and liquid milk was investigated. In the present work four kinds of Al cook wares from four countries were chosen from the local market. Extracts of boiled meat (lamb, chicken, and fish) were used to make 10–50% (w/v) concentrations. In addition liquid fresh milk and long life milk were diluted to make 10–50% (v/v) concentrations. Weight loss (WL) method, atomic absorption, polarization method, and surface study were applied. The “estimated” Al intake per person from WL in 30% meat extract and milk range from 8.16 to 12.75 mg/h with fish extract having the highest leaching and chicken extract having the lowest leaching. Atomic absorption gave comparable results to that of WL. Comparing the present results with the Provisional Tolerance Weekly Intake of Al approved by the FDA/WHO shows that Al leaching from Al cook wares may add high doses of Al into the diet.  相似文献   
9.
    
We studied the effect of ultrasonic activation of brine (3%) during salting on the degree of stability of colour parameters of pork with normal (NOR) and abnormal course of autolysis in the CIE Lab colour space. The mechanism of stabilisation of the colour of meat is attributed to donor–acceptor bonds of metmyoglobin (MetMb). The accumulation of excessive number of free electrons in the medium are capable of activating MetMb. This reduces the activity of meat, when the native participants of the metmyoglobin reductase system and their own antioxidant systems of meat are depleted.Based on the additive calculation of deviations (increase / decrease) by the coordinates L*, a*, b* in the CIE Lab system, and the total colour difference (ΔE) in control and experimental samples, recommendations were developed. To optimize the colour characteristics of all types of meat, both on the surface and in the thickness of the meat, the preliminary activation of a 3% brine in a low-frequency submersible ultrasonic unit is recommended. Moreover, preliminary cavitation activation of a 3% is more preferable to stabilise the colour of PSE – meat (pale, soft, exudative (watery),) brine in a flow-through installation.  相似文献   
10.
肉类样品用乙醇提取,经C18固相萃取柱,甲醇(10+90)2mL淋洗,甲醇2mL洗脱。采用HypersilC18色谱柱(250mm×4.6mm,5μm),甲醇-磷酸(1+99)为流动相(75∶25),流速1mL.min-1,柱温26℃,紫外检测波长240nm测定。克伦特罗、多巴胺、己烯雌酚、睾丸素、黄体酮五种激素类生长促进剂成分可同时测定,检出限分别为0.4,2.4,0.3,0.5,0.4μg.g-1,平均回收率分别为99.0%,98.0%,100.7%,97.5%,94.0%,RSD分别为2.7%,1.2%,2.3%,2.3%,3.5%。检测方法简便快速、可靠准确。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号