首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
  国内免费   1篇
化学   14篇
物理学   7篇
  2020年   1篇
  2016年   2篇
  2014年   1篇
  2012年   1篇
  2011年   1篇
  2010年   6篇
  2009年   3篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2003年   2篇
排序方式: 共有21条查询结果,搜索用时 15 毫秒
1.
A general understanding of interactions between DNA and oppositely charged compounds forms the basis for developing novel DNA-based materials, including gel particles. The association strength, which is altered by varying the chemical structure of the cationic cosolute, determines the spatial homogeneity of the gelation process, creating DNA reservoir devices and DNA matrix devices that can be designed to release either single- (ssDNA) or double-stranded (dsDNA) DNA. This review covers recent developments on the topic of DNA gel particles formed in water–water emulsion-type interfaces. The degree of DNA entrapment, particle morphology, swelling/dissolution behavior and DNA release responses are discussed as functions of the nature of the cationic agent used. On the basis of designing DNA gel particles for therapeutic purposes, recent studies on the determination of the surface hydrophobicity and the hemolytic and the cytotoxic assessments of the obtained DNA gel particles have been also reported.  相似文献   
2.
In the present study, bovine serum albumin (BSA) was successfully covalently immobilized on the surface of anatase TiO2 film by a three-step method, i.e. application of H3PO4 chemisorption to increase surface -OH, which increases the amount of coupling 3-aminopropyl-triethoxylsilane (APTES), thus linking with BSA by imide bond using EDC/NHS/MES. There is no significant -OH group increase on rutile film when using the same method of phosphoric acid treatment, which suggest it is difficult for further chemical modification of the rutile film. After covalent immobilization of BSA on anatase film, an improved hemocompatibility of anti-platelet adhesion and aggregation in vitro could be recognized by LDH and SEM analysis. This study suggests BSA-immobilized anatase surface can serve as hemocompatibility material in vivo.  相似文献   
3.
Poly(styrene-b-(ethylene-co-butylene)-b-styrene) (SEBS) copolymer biomedical elastomer was covalently grafted with poly(ethylene glycol) methyl ether methacrylate (PEGMA) via a photo-initiated graft polymerization technique. The surface graft polymerization of SEBS with PEGMA was verified by ATR-FTIR and XPS. Effect of graft polymerization parameters, i.e., monomer concentration, UV irradiation time and initiator concentration on the grafting density was investigated. Comparing with the virgin SEBS film, the PEGMA-modified SEBS film presented an enhanced wettability and a larger surface energy. Besides, the surface grafting of PEGMA imparted excellent anti-platelet adhesion and anti-protein adsorption to the SEBS surface.  相似文献   
4.
A new zwitterionic surface was obtained by a novel three-step grafting procedure. The zwitterionic monomer was introduced by cerium-induced graft copolymerization in the presence of N,N′-methylene bisacrylamide (MBAA) as cross-linking agent. Attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS) analysis confirmed the MBAA could stimulate zwitterionic monomer grafting onto the membrane surface. Surface properties were also determined by atomic force microscope (AFM) and water contact angle. The hemocompatibility of the modified PU membranes was evaluated by the activated partial thromboplastin time (APTT), thrombin time (TT) and prothrombin time (PT). The TT and APTT of PU were significantly prolonged by the zwitterion of sulfobetaine monomer grafting copolymerization. The new polyurethane membrane could have a great potential in biomedical applications.  相似文献   
5.
End-stage renal diseases are affecting many patients and as a result, demand to receive dialysis service is growing annually. Morbidity and mortality rates are reported to be higher in comparison with healthy humans. The reason is reported to be the hemoincompatiblity of blood purification membranes, which hinders patients’ lives. Activation of different immune systems in the body, in case of blood-membrane interaction, results in several side effects, of which cardiovascular shocks have been mentioned to be a major one. Efforts to solve this issue have resulted in different generations of dialysis membranes. Zwitterionic immobilized membranes are the latest (third) generation, which owns a higher degree of hemocompatiblity with more stability of immobilized structures. This critical review intends to cover recent efforts conducted over the zwitterionization of polymeric membrane surfaces with the goal of improving hemocompatibility. Different aspects of third-generation membranes are discussed for a better understanding of the current gap and gathering the knowledge to further develop the field. Accordingly, this critical survey provides an in-depth understanding of blood purification membranes zwitterionization for paving the way for the optimum enhancement of hemodialysis membrane hemocompatibility.  相似文献   
6.
A stable hemocompatible coating was fabricated by consecutive alternating adsorption of iron (III) and two kinds of polysaccharides, heparin (Hep) and dextran sulfate (DS), onto poly (vinyl chloride) (PVC) surfaces via electrostatic interaction. The fluctuation of contact angles with the alternative deposition of iron (III) and polysaccharides verified the progressive buildup of the mulitilayer coating onto the PVC surface. Atomic force microscopy (AFM) analysis revealed that the PVC surfaces were completely masked by iron-polysaccharides multilayer coatings. The activated partial thromboplastin time (APTT) assay showed that both Hep/Fe3+/Hep and DS/Fe3+/Hep coated PVC were less thrombogenic than the uncoated one. Chromogenic assay for heparin activity proved definitively that the inhibition of locally produced thrombin was ascribed to the thromboresistance of the surface-bound heparin. Compared with the unmodified PVC surfaces, iron-polysaccharide multilayer coating presented a drastically reduced adhesion in vitro of platelets, polymorphonuclear neutrophil leukocytes (PMN) and peripheral blood mononuclear cells (PBMC). Interestingly, the DS/Fe3+/Hep coating was found to exhibit higher hydrophilicity and stability, hence lower non-specific protein adsorption in comparison with Hep/Fe3+/Hep coating due to the incorporation of dextran sulfate into the multilayer coating.  相似文献   
7.
The improvement of hydrophilicity and hemocompatibility of poly(tetramethylene adipate-co-terephthalate) (PTAT) membrane was developed via polyelectrolyte multilayers (PEMs) immobilization. The polysaccharide PEMs included chitosan (CS, as a positive-charged and antibacterial agent) and dextran sulfate (DS, as a negative-charged and anti-adhesive agent) were successfully prepared using the aminolyzed PTAT membrane in a layer-by-layer (LBL) self-assembly manner. The obtained results showed that the contact angle of as-modified PTAT membranes reached to the steady value after four bilayers of coating, hence suggesting that the full coverage was achieved. It could be found that the PTAT–PEMs membranes with DS as the outmost layer could resist the platelet adhesion and human plasma fibrinogen (HPF) adsorption, thereby prolonging effectively the blood coagulation times. According to L929 fibroblast cell growth inhibition index, the as-prepared PTAT membranes exhibited non-cytotoxic. Overall results demonstrated that such an easy, valid and shape-independent processing should be potential for surface modification of PTAT membrane in the application of hemodialysis devices.  相似文献   
8.
Carbon nitride thin films were obtained through plasma assisted physical vapor deposition technique by pulsed arc, varying the substrate temperature and investigating the influence of this parameter on the films hemocompatibility. For obtaining approaches of blood compatibility, environmental scanning electron microscopy (ESEM) was used in order to study the platelets adherence and their morphology. Moreover, the elemental chemical composition was determined by using energy dispersive spectroscopy (EDS), finding C, N and O. The coatings hemocompatibility was evaluated by in vitro thrombogenicity test, whose results were correlated with the microstructure and roughness of the films obtained.During the films growth process, the substrate temperature was varied, obtaining coatings under different temperatures, room temperature (Troom), 100 °C, 150 °C and 200 °C. Parameters as interelectrodic distance, voltage, work pressure and number of discharges, were remained constant. By EDS, carbon and nitrogen were found in the films.Visible Raman spectroscopy was used, and it revealed an amorphous lattice, with graphitic process as the substrate temperature was increased. However, at a critical temperature of 150 °C, this tendency was broken, and the film became more amorphous. This film showed the lowest roughness, 2 ± 1 nm. This last characteristic favored the films hemocompatibility. Also, it was demonstrated that the blood compatibility of carbon nitride films obtained were affected by the ID/IG or sp3/sp2 ratio and not by the absolute sp3 or sp2 concentration.  相似文献   
9.
Polypropylene (PP) was modified with 2-hydroxyethyl acrylate (HEA) by solution radical grafting to introduce active hydroxyl groups on polypropylene backbone (PP-g-HEA). Then the biomimic monomer, 2-methacryloyloxyethyl phosphorycholine (MPC), was grafted onto the surface of PP-g-HEA film (PP-g-HEA-g-MPC) by redox graft polymerizations with ceric(IV) ammonium nitrate as an initiator. Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS) showed that the HEA and MPC were introduced onto PP molecular chains and the copolymer, PP-g-HEA-g-MPC were formed. The water contact angle measurements demonstrated that the final modified PP film exhibited a better hydrophilic surface compared to the neat PP film. The platelets adhesion on the neat PP, PP-g-HEA and PP-g-HEA-g-MPC film was examined by scanning electron microscopy (SEM). It was found that a large number of platelets were adhered and activated on the surface of neat PP and PP-g-HEA films, while the number of platelets on PP-g-HEA-g-MPC surface was decreased remarkably. The result revealed that the introduction of poly(MPC) onto the PP surface improved the hemocompatibility of PP substantially.  相似文献   
10.
李洁华  谭鸿 《高分子科学》2016,34(6):679-687
In this study, to improve hemocompatibility of biomedical materials, a waterborne polyurethane (WPU)/heparin release coating system (WPU/heparin) is fabricated via simply blending biodegradable WPU emulsions with heparin aqueous solutions. The surface compositions and hydrophilicity of these WPU/heparin blend coatings are characterized by attenuated total reflectance infrared spectroscopy (ATR-FTIR) and water contact angle measurements. These WPU/heparin blend coatings show effectively controlled release of heparin, as determined by the toluidine blue method. Furthermore, the biocompatibility and anticoagulant activity of these blend coatings are evaluated based on the protein adsorption, platelet adhesion, activated partial thromboplastin time (APTT), thrombin time (TT), hemolysis, and cytotoxicity. The results indicate that better hemocompatibility and cytocompatilibity are obtained due to blending heparin into this waterborne polyurethane. Thus, the WPU/heparin blend coating system is expected to be valuable for various biomedical applications.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号