首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   2篇
  国内免费   6篇
物理学   13篇
  2018年   1篇
  2017年   1篇
  2012年   1篇
  2011年   3篇
  2009年   3篇
  2008年   2篇
  2007年   2篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
We examine the two-pion Hanbury-Brown-Twiss (HBT) interferometry for the particle-emitting source produced in heavy ion collisions at HIRFL-CSR energy. The source evolution is described by relativistic hydrodynamics with three kinds of equations of state for chemical equilibrium (CE), chemical freeze-out (CFO), and partial chemical equilibrium (PCE) models, respectively. We investigate the effects of particle decay, multiple scattering, and source collective expansion on the two-pion interferometry results. We find that the HBT radii of the evolution source for the CFO and PCE models are smaller than that for the CE model. The HBT lifetime for the CFO model is smaller than those for the PCE and CE models. The particle decay increases the HBT radius and lifetime while the source  相似文献   
2.
用于重离子加速器磁铁电源的数字调节器设计   总被引:1,自引:0,他引:1       下载免费PDF全文
 介绍了兰州重离子加速器冷却储存环上采用高级RISC微处理器(ARM)+现场可编程门阵列(FPGA)+DA/AD技术、状态空间方程方法实现对磁铁电源系统数字调节器的设计,它可以实现5阶及以下各阶的调节控制。运用ARM作为调节控制系统的核心处理器,完成系统的多线程任务处理。电源的精度调节通过FPGA和DA/AD相结合的技术来实现,通过千兆光纤接口实现外接数字信号处理器输入信号的直接传输。同时通过光电隔离器对叠加在输入/输出32 bit数字状态量的干扰脉冲进行抑制。经现场测试该调节器达到了加速器电源系统1×10-4量级的精度要求,并减少了电源系统的故障恢复时间。  相似文献   
3.
Particles in a storage ring oscillate in the longitudinal and transverse dimensions.Therefore,the signal that beam has generated can be analyzed in the frequency domain to extract many beam parameters,such as tune,momentum spread,emittance and their evolution with time and so on.In this paper,the transverse spectrum in HIRFI-CSR was simulated and analyzed under different conditions,including electron cooling,hollow electron beam,solenoid effect,the tune shift caused by power supply ripple and the misalignment between ion and electron beams.The result of the simulation shows that the longitudinal magnetic field of the electron cooling device should be compensated by a "compensation solenoid",and the power supply ripple must be controlled,otherwise the accumulation would be affected and the beam would be lost.  相似文献   
4.
在兰州重离子加速器冷却储存环(HIRFL-CSR)上,用等时性质量谱仪首次研究了百微秒量级全剥离离子94mRu44+的衰变。94mRu44+由初级束流112Sn轰击Be靶产生,经过放射性束流线RIBLL2的筛选后注入到等时性设置的实验环CSRe中,并利用安装在实验环中的飞行时间探测器测量离子在CSRe中的循环周期。94mRu44+退激引起的质量改变会带来其循环周期的变化,由此直接观测到了94mRu44+退激到基态的过程。确定了本次实验中衰变事例探测的灵敏区间,并讨论了衰变发生时刻的测量精度。同时,测量了短寿命核素94mRu44+的质量,其半衰期约为100 μs,这是目前储存环质量谱仪测量的最短寿命核素的质量。The decay of the fully stripped ion 94mRu44+ in the order of one hundred microseconds has been studied for the first time by using the Isochronous Mass Spectrometry (IMS) at the HIRFL-CSR facility in Lanzhou. 94mRu44+ was produced via projectile fragmentation of a 112Sn primary beam bombarding on a 9Be production target. After the in-flight separation with RIBLL2, the ions were injected into the experimental ring (CSRe) and then stored there. The revolution times of the stored ions were measured by a Time-of-Flight (TOF) detector. Due to the mass change of a 94mRu44+ ion caused by its de-excitation to the ground state, hence the revolution time change, the decay process of 94mRu44+ could be directly observed in the CSRe. The sensitive window for detection of the decay events and the measurement precision of the decay time have been determined in this work. At the same time, we measured the mass of short-lived 94mRu44+ with the half-life about one hundred microseconds, which is the shortest among nuclides that have been studied by using storage-ring mass-spectrometry.  相似文献   
5.
在兰州重离子加速器冷却储存环(HIRFL-CSR)上,用初级束流112Sn35+轰击了靶厚约10 mm的Be靶,产生了101In的基态和低位同核异能态。这些实验产生的碎片每25 s经过放射性束流线RIBLL2的筛选后注入到实验环CSRe中,利用飞行时间探测器测量离子在CSRe中的回旋周期。在此次实验中,磁场晃动会导致离子在环内的循环周期发生改变,传统的离子鉴别方法难以完成大部分离子的鉴别。通过发展和运用单次注入离子鉴别这一新的离子鉴别方法,有效地消除了磁场晃动对于离子鉴别的影响,并清楚地将101In基态和低位同核异能态鉴别出来,从而首次在实验中观测到101In的低位同核异能态。实验得到的激发能与理论外推值在112 keV的误差范围内一致,其低位同核异能态的寿命大于200 μs。Isochronous mass spectrometry has been applied to 112Sn projectile fragments at the HIRFL-CSR facility in Lanzhou. To produce short-lived nuclei of interest, we used projectile fragmentation of 112Sn35+ primary beams in a~10 mm thick 9Be production target. The fragments were selected and analyzed by RIBLL2 and injected into the experimental storage ring(CSRe) every 25 s. To measure revolution times of stored ions,we used a Time-Of-Flight detector installed in CSRe. A new particle identification method was developed to distinguish ions on the measured revolution time spectrum for each injection. Based on this method, the shifts of the revolution time due to instable dipole magnet fields can be corrected and the ground and isomeric states of 101In have been well-resolved. The measured excitation energy is consistent with the theoretical value in the error range of 112 keV. The lifetime of the isomeric states of 101In is more than 200 μs.  相似文献   
6.
With the commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou (HIRFL-CSR),a pilot experiment operating the CSRe in isochronous mode to test the power of HIRFL-CSR for measuring the mass of the short-lived nucleus was performed in December of 2007.The fragments with A/q=2 of ~(36) Ar were injected into CSRe and their revolution frequencies were measured with a fast time pick-up detector with a thin foil in the circulating path of the ions.The preliminary result is presented.The result shows the potential of CSRe for mass measurements of short-lived nuclei.  相似文献   
7.
We examine the two-pion Hanbury-Brown-Twiss (HBT) interferometry for the particle-emitting source produced in heavy ion collisions at HIRFL-CSR energy. The source evolution is described by relativistic hydrodynamics with three kinds of equations of state for chemical equilibrium (CE), chemical freeze-out (CFO),and partial chemical equilibrium (PCE) models, respectively. We investigate the effects of particle decay,multiple scattering, and source collective expansion on the two-pion interferometry results. We find that the HBT radii of the evolution source for the CFO and PCE models are smaller than that for the CE model.The HBT lifetime for the CFO model is smaller than those for the PCE and CE models. The particle decay increases the HBT radius and lifetime while the source expansion decreases the HBT radius. The multiple scattering effect on the HBT results can be neglected based on our model calculations.  相似文献   
8.
Imaging analysis of two-pion interferometry is performed for an evolving particle-emitting source in heavy ion collisions at HIRFL-CSR energy. The source evolution is described by the relativistic hydrodynamics in (2+1) dimensions. The model-independent characteristic quantities of the source are investigated and compared with the interferometry results obtained by the usual Gaussian formula fit. It is found that the first- order source function moments can describe the source sizes. The ratio of the normalized standard deviation σ to the first-order moment R, σ/R, is sensitive to the shape of the source function.  相似文献   
9.
Particles in a storage ring oscillate in the longitudinal and transverse dimensions. Therefore, the signal that beam has generated can be analyzed in the frequency domain to extract many beam parameters, such as tune, momentum spread, emittance and their evolution with time and so on. In this paper, the transverse spectrum in HIRFL-CSR was simulated and analyzed under different conditions, including electron cooling, hollow electron beam, solenoid effect, the tune shift caused by power supply ripple and the misalignment between ion and electron beams. The result of the simulation shows that the longitudinal magnetic field of the electron cooling device should be compensated by a “compensation solenoid”, and the power supply ripple must be controlled, otherwise the accumulation would be affected and the beam would be lost.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号