首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
物理学   13篇
  2017年   1篇
  2014年   3篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2009年   2篇
  2008年   3篇
  2007年   1篇
排序方式: 共有13条查询结果,搜索用时 0 毫秒
1.
Magnetic Resonance Spectroscopic Imaging (MRSI) is a technique for imaging spatial variation of metabolites and has been very useful in characterizing biochemical changes associated with disease as well as response to therapy in malignant pathologies. This work presents a self-calibrated undersampling to accelerate 3D elliptical MRSI and an extrapolation-reconstruction algorithm based on the GRAPPA method. The accelerated MRSI technique was tested in three volunteers and five brain tumor patients. Acceleration allowed larger spatial coverage and consequently, less lipid contamination in spectra, compared to fully sampled acquisition within the same scantime. Metabolite concentrations measured from the accelerated acquisitions were in good agreement with measurements obtained from fully sampled MRSI scans.  相似文献   
2.
Combination of non-Cartesian trajectories with parallel MRI permits to attain unmatched acceleration rates when compared to traditional Cartesian MRI during real-time imaging. However, computationally demanding reconstructions of such imaging techniques, such as k-space domain radial generalized auto-calibrating partially parallel acquisitions (radial GRAPPA) and image domain conjugate gradient sensitivity encoding (CG-SENSE), lead to longer reconstruction times and unacceptable latency for online real-time MRI on conventional computational hardware. Though CG-SENSE has been shown to work with low-latency using a general purpose graphics processing unit (GPU), to the best of our knowledge, no such effort has been made for radial GRAPPA. Radial GRAPPA reconstruction, which is robust even with highly undersampled acquisitions, is not iterative, requiring only significant computation during initial calibration while achieving good image quality for low-latency imaging applications. In this work, we present a very fast, low-latency, reconstruction framework based on a heterogeneous system using multi-core CPUs and GPUs. We demonstrate an implementation of radial GRAPPA that permits reconstruction times on par with or faster than acquisition of highly accelerated datasets in both cardiac and dynamic musculoskeletal imaging scenarios. Acquisition and reconstruction times are reported.  相似文献   
3.
General theory of a new reconstruction technique for partially parallel imaging (PPI) is presented in this study. Reconstruction in Image space using Basis functions (RIB) is based on the general principle that the PPI reconstruction in image space can be represented by a pixel-wise weighted summation of the aliased images directly from undersampled data. By assuming that these weighting coefficients for unaliasing can be approximated from the linear combination of a few predefined basis functions, RIB is capable of reconstructing the image within an arbitrary region. This paper discusses the general theory of RIB and its relationship to the classical reconstruction method, GRAPPA. The presented experiments demonstrate RIB with several MRI applications. It is shown that the performance of RIB is comparable to that of GRAPPA. In some cases, RIB shows advantages of increasing reconstruction efficiency, suppressing artifacts and alleviating the nonuniformity of noise distribution. It is anticipated that RIB would be especially useful for cardiac and prostate imaging, where the field of view during data acquisition is required to be much larger than the region of interest.  相似文献   
4.
k-space-based reconstruction in parallel imaging depends on the reconstruction kernel setting, including its support. An optimal choice of the kernel depends on the calibration data, coil geometry and signal-to-noise ratio, as well as the criterion used. In this work, data consistency, imposed by the shift invariance requirement of the kernel, is introduced as a goodness measure of k-space-based reconstruction in parallel imaging and demonstrated. Data consistency error (DCE) is calculated as the sum of squared difference between the acquired signals and their estimates obtained based on the interpolation of the estimated missing data. A resemblance between DCE and the mean square error in the reconstructed image was found, demonstrating DCE's potential as a metric for comparing or choosing reconstructions. When used for selecting the kernel support for generalized autocalibrating partially parallel acquisition (GRAPPA) reconstruction and the set of frames for calibration as well as the kernel support in temporal GRAPPA reconstruction, DCE led to improved images over existing methods. Data consistency error is efficient to evaluate, robust for selecting reconstruction parameters and suitable for characterizing and optimizing k-space-based reconstruction in parallel imaging.  相似文献   
5.
磁共振成像(MRI)无创无害、对比度多、可以任意剖面成像的特点特别适合用于心脏成像,却因扫描时间长限制了其在临床上的应用.为了解决心脏磁共振电影成像屏气扫描时间过长的问题,该文提出了一种基于同时多层激发的多倍加速心脏磁共振电影成像及其影像重建的方法,该方法将相位调制多层激发(CAIPIRINHA)技术与并行加速(PPA)技术相结合,运用到分段采集心脏电影成像序列中,实现了在相位编码方向和选层方向的四倍加速,并使用改进的SENSE/GRAPPA算法对图像进行重建.分别在水模以及人体上进行了实验,将加速序列图像与不加速序列图像进行对比,结果验证了重建算法的有效性,表明该方法可以在保障图像质量以及准确测量心脏功能的前提下成倍节省扫描时间.  相似文献   
6.
Echo Planar Imaging (EPI) is a neuroimaging tool for clinical practice and research investigation. Due to odd-even echo phase inconsistencies, however, EPI suffers from Nyquist N/2 ghost artifacts. In standard neuroimaging protocols, EPI artifacts are suppressed using phase correction techniques that require reference data collected from a reference scan. Because reference-scan based techniques are sensitive to subject motion, EPI performance is sub-optimal in neuroimaging applications. In this technical note, we present a novel EPI data processing technique which we call Parallel EPI Artifact Correction (PEAC). By introducing an implicit data constraint associated with multi-coil sensitivity in parallel imaging, PEAC converts phase correction into a constrained problem that can be resolved using an iterative algorithm. This enables “reference-less” EPI that can improve neuroimaging performance. In the presented work, PEAC is investigated using a standard functional magnetic resonance imaging (fMRI) protocol with multi-slice 2D EPI. It is demonstrated that PEAC can suppress ghost artifacts as effectively as the standard reference-scan based phase correction technique used on a clinical MRI system. We also found that PEAC can achieve dynamic phase correction when motion occurs.  相似文献   
7.
Accuracy of interpolation coefficients fitting to the auto-calibrating signal data is crucial for k-space-based parallel reconstruction. Both conventional generalized autocalibrating partially parallel acquisitions (GRAPPA) reconstruction that utilizes linear interpolation function and nonlinear GRAPPA (NLGRAPPA) reconstruction with polynomial kernel function are sensitive to interpolation window and often cannot consistently produce good results for overall acceleration factors. In this study, sparse multi-kernel learning is conducted within the framework of least squares support vector regression to fit interpolation coefficients as well as to reconstruct images robustly under different subsampling patterns and coil datasets. The kernel combination weights and interpolation coefficients are adaptively determined by efficient semi-infinite linear programming techniques. Experimental results on phantom and in vivo data indicate that the proposed method can automatically achieve an optimized compromise between noise suppression and residual artifacts for various sampling schemes. Compared with NLGRAPPA, our method is significantly less sensitive to the interpolation window and kernel parameters.  相似文献   
8.
Parallel imaging methods allow to increase the acquisition rate via subsampled acquisitions of the k-space. SENSE and GRAPPA are the most popular reconstruction methods proposed in order to suppress the artifacts created by this subsampling. The reconstruction process carried out by both methods yields to a variance of noise value which is dependent on the position within the final image. Hence, the traditional noise estimation methods – based on a single noise level for the whole image – fail. In this paper we propose a novel methodology to estimate the spatial dependent pattern of the variance of noise in SENSE and GRAPPA reconstructed images. In both cases, some additional information must be known beforehand: the sensitivity maps of each receiver coil in the SENSE case and the reconstruction coefficients for GRAPPA.  相似文献   
9.
This article presents a method to explore the flexibility of channel reduction in k-domain parallel imaging (PI) with massive arrays to improve the computation efficiency. In PI, computation cost increases with the number of channels. For the k-domain methods requiring channel-by-channel reconstruction, this increase can be significant with massive arrays. In this article, a method for efficient k-domain PI reconstruction in large array systems is proposed. The method is based on the fact that in large arrays the channel sensitivity is localized, which allows channel reduction through channel cross correlation. The method is tested with simulated and in vivo MRI data from a 32-channel and 64-channel systems using the multicolumn multiline interpolation (MCMLI) method. Results show that the proposed algorithm can achieve similar or improved reconstruction quality with significantly reduced computation time for massive arrays with localized sensitivity.  相似文献   
10.
We developed a dynamic magnetic resonance (MR) angiographic imaging protocol that can aide the diagnosis of subclavian steal syndrome (SSS). Our protocol combines a new pulse sequence: time-resolved echo-shared angiographic technique (TREAT) with parallel imaging: generalized autocalibrating partially parallel acquisition (GRAPPA). Our pulse sequence, like traditional catheter angiography exams, provides anatomic and dynamic flow pattern information in one scan. If included in comprehensive SSS MR imaging examinations, this sequence can potentially reduce the need for diagnostic X-ray angiography.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号