1.
A motion-correcting pulse sequence and reconstruction algorithm, termed TRELLIS, is presented. k-Space is filled using orthogonal overlapping strips and the directions for phase- and frequency-encoding are alternated such that the frequency-encode direction always runs lengthwise along each strip. The overlap between strips is used both for signal averaging and to produce a system of equations that, when solved, quantifies the rotational and translational motion of the object. Results obtained from simulations with computer-generated phantoms, a purpose-built moving phantom, and in human subjects show the method is effective. TRELLIS offers some advantages over existing techniques in that k-space is sampled uniformly and all acquired data are used for both motion detection and image reconstruction. 相似文献
2.
Density Matrix Simulations of the Effects of J Coupling in Spin Echo and Fast Spin Echo Imaging 总被引:1,自引:0,他引:1
L. A. Stables R. P. Kennan A. W. Anderson J. C. Gore 《Journal of magnetic resonance (San Diego, Calif. : 1997)》1999,140(2):305-314
A computer simulation has been used to calculate the effects of J coupling on the amplitudes of echoes produced by CPMG sequences. The program computes the evolution of the density matrix for different pulse intervals and can predict the signals obtainable from spin systems of any size and complexity. Results from the simulation confirm the prediction that a decrease in the effects of J coupling is largely responsible for the bright fat signal seen in fast spin echo imaging at high pulse rates. The effects of J coupling on CPMG echotrains are examined for A3B2 and A3B2C2 spin systems over a wide range of J coupling and chemical shift values and pulse spacings. The effects of J coupling on the point spread function obtained with fast spin echo imaging are also discussed. 相似文献
3.
Marion de Roquefeuil Pierre-André Vuissoz Jean-Marie Escanyé Jacques Felblinger 《Magnetic resonance imaging》2013
Object
Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject to physiological variability, which causes repetition time variations and affects the recovery of longitudinal magnetization between TR periods.Materials and methods
The bias caused by heart rate variability on quantitative T2 measurements is evaluated for fast spin echo pulse sequence. Its retrospective correction based on an effective TR is proposed. Heart rate variations during breath-holds are provided by the ECG recordings from healthy volunteers. T2 measurements were performed on a phantom with known T2 values, by synchronizing the sequence with the recorded ECG. Cardiac T2 measurements were performed twice on six volunteers. The impact of T1 on T2 is also studied.Results
Maximum error in T2 is 26% for phantoms and 18% for myocardial measurement. It is reduced by the proposed compensation method to 20% for phantoms and 10% for in vivo measurements. Only approximate knowledge of T1 is needed for T2 correction.Conclusion
Heart rate variability may cause a bias in T2 measurement with ECG-gated FSE. It needs to be taken into account to avoid a misleading diagnosis from the measurements. 相似文献4.