排序方式: 共有16条查询结果,搜索用时 0 毫秒
1.
2.
选择304LN 不锈钢作为冷屏的制作材料,将杜瓦冷屏分为16 个扇区,每个扇区由20 个子部分组成,在每一个子部分上布置相应的冷却管。选择液氦作为冷却剂。为检验杜瓦冷屏结构是否符合设计要求,分析了杜瓦冷屏的传热方式以及冷却原理,利用FLUENT 软件对设计的冷屏结构进行了热分析,得到了杜瓦冷屏面板的温度分布情况以及冷却管道进出口压力差。结果表明,杜瓦冷屏面板温度和冷却管道进出口压力差在合理范围内,验证了冷却管道布局的合理性,为后续杜瓦冷屏的设计提供了重要参考。 相似文献
3.
The temperature variation of the Debye-Waller factors of Cs+ and Br− ions in CsBr powder has been studied using powder X-ray diffraction. The integrated intensities of the Bragg peaks at different
temperatures have been obtained. These results have been verified by structure factor least squares refinement program. Theoretical
shell model lattice dynamical calculations have been done using a 7-parameter model in the harmonic approximation and the
values compared with the present X-ray measurements. The observed intensities have been corrected for first order thermal
diffuse scattering. 相似文献
4.
5.
设计了一种用于研究金属有机骨架(MOFs)材料低温储氢性能的低温恒温器。介绍了其设计原理及具体结构。该低温恒温器能够为多种MOFs材料提供低温宽温区范围内的温度环境,且样品更换方便。 相似文献
6.
高温超导电缆终端恒温器是高温超导电缆终端系统的重要组成部分,其长期可靠稳定的运行将为整个系统的良好运转奠定坚实基础.文中对成功研制的高温超导电缆终端恒温器进行了详细介绍,包括技术指标及相关要求、总体结构、关键技术、热负荷分析与计算等.试验表明,高温超导电缆终端恒温器结构设计合理、操作方便;大口径可拆法兰低温真空压力环境下的密封技术得到突破、密封性能良好;低温液体输送管道承插密封结构设计新颖、满足工作要求.热负荷的分析与计算为高温超导电缆制冷系统所需冷量的确定提供了依据,同时也为终端恒温器的进一步优化指明了方向. 相似文献
7.
The temperature variation of the Debye-Waller factors of Cs+ and Cl− ions in CsCl powder has been studied using X-ray powder diffraction. A continuous flow cryostat has been used to record the
diffractograms and the integrated intensities of the Bragg peaks at different temperatures have been obtained. The integrated
intensities of the odd and even reflections have been analysed following the structure of the CsCl compound and the Debye-Waller
factors of the Cs+ and Cl− ions have been estimated. The results have been verified by structure factor least squares refinement. Theoretical shell
model lattice dynamical calculations have been done using a 7-parameter model in the harmonic approximation and the values
compared with the present X-ray measurements. 相似文献
8.
The temperature variation of the Debye-Waller factors of Ba++ and F− ions in BaF2 powder has been studied using x-ray powder diffraction over the temperature range 77°–298°K. A continuous flow cryostat has
been specially fabricated for this purpose for the YPC 50 NM powder diffractometer available in the department. The Debye-Waller
factors of Ba++ and F− between room temperature and 879°K have been measured using single crystal neutron diffraction by Cooperet al. Theoretical lattice dynamics shell model calculations using a 7-parameter model in a quasiharmonic approximation have been
done over a temperature range 77° to 879°K. The theoretical values have been compared with the present x-ray measurements
and the single crystal neutron diffraction values and the results are discussed. 相似文献
9.
10.