排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
RF system design and measurement of HIRF-CSRe 总被引:1,自引:0,他引:1
An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections: ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB interface and has three feedback loops. Finally we give the results of the measurement on our system. 相似文献
2.
An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections:ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB interface and has three feedback loops. Finally we give the results of the measurement on our system. 相似文献
3.
Secondary electron time detector for mass measurements at CSRe 总被引:1,自引:0,他引:1
TU Xiao-Lin WANG Meng HU Zheng-Guo XU Hu-Shan GUO Zhong-Yan MAO Rui-Shi XIAO Guo-Qing ZHANG Hong-Bin ZANG Yong-Dong YUE Ke 《中国物理C(英文版)》2010,34(3)
The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deffected 180° by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10-6 for m/m was achieved by using this time detector in a pilot mass measurement experiment. 相似文献
4.
介绍了兰州重离子冷却储存环主环(CSRm)的改进W型二极磁铁和实验环(CSRe)C型二极磁铁的磁场计算和物理设计,在降低了磁铁造价和运行费用的前提下设计参数达到或超过了物理要求.根据样机的加工和检测结果来看,所有的磁场计算和物理设计的结果是可靠的.Magnetic field calculation and design of CSRm modified W-type dipoles and of CSRe C-type dipoles are presented in this paper. Under the condition of lower cost, all of the designed parameters are better than required values. Now the prototype has been fabricated and also the magnetic field measurement has been done. According to the measured results, all the calculation and design are very reliable. 相似文献
5.
Commissioning of electron cooling in CSRe 总被引:1,自引:0,他引:1
杨晓东 冒立军 李国宏 李杰 马晓明 晏太来 原有进 宋明涛 杨建成 刘勇 赵铁成 夏佳文 张玮 高大庆 周忠祖 燕宏斌 毛瑞士 何源 韩少斐 郑建华 杨晓天 赵红卫 肖国青 殷达钰 李朋 贾欢 Parkhomchuk Vasily Reva Vladimir Skorobogatov Dmitry 《中国物理 C》2010,34(7):998-1004
The 400 MeV/u 12C6+ ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe.The momentum cooling time was estimated near 15 s.The cooling force was measured in the cases of difierent electron beam profiles,and the difierent angles between the ion beam and electron beam.The lifetime of the ion beam in CSRe was over 80 h.The dispersion in the cooling section was confirmed as positive close to zero.The beam sizes before cooling and after cooling were measured by the moving screen.The beam diameter after cooling was about 1 mm.The bunch length was measured with the help of the signals from the beam position monitor.The difiusion was studied in the absence of the electron beam. 相似文献
6.
7.
YANG Xiao-Dong MAO Li-Jun LI Guo-Hong LI Jie MA Xiao-Ming YAN Tai-Lai YUAN You-Jin SONG Ming-Tao YANG Jian-Cheng LIU Yong ZHAO Tie-Cheng XIA Jia-Wen ZHANG Wei GAO Da-Qing ZHOU Zhong-Zu YAN Hong-Bin MAO Rui-Shi HE Yuan HAN Shao-Fei ZHENG Jian-Hua YANG Xiao-Tian ZHAO Hong-Wei XIAO Guo-Qing YIN Da-Yu LI Peng JIA Huan Parkhomchuk Vasily Reva Vladimir Skorobogatov Dmitry 《中国物理C(英文版)》2010,34(7)
The 400 MeV/u 12C6+ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe.The momentum cooling time was estimated near 15 s.The cooling force was measured in the cases of different electron beam profiles,and the different angles between the ion beam and electron beam.The lifetime of the ion beam in CSRe was over 80 h.The dispersion in the cooling section was confirmed as positive close to zero.The beam sizes before cooling and after cooling were measured by the moving screen.The beam diameter after cooling was about 1 mm.The bunch length was measured with the help of the signals from the beam position monitor.The diffusion was studied in the absence of the electron beam. 相似文献
8.
Secondary electron time detector for mass measurements at CSRe 总被引:1,自引:0,他引:1
The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deflected 180°by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10^-6 for Am/m was achieved by using this time detector in a pilot mass measurement experiment. 相似文献
9.
XU Hu-shan 《原子核物理评论》2009,26(Z1)
The research activities at HIRFL cover the fields of radio-biology,material science,atomic physics,and nuclear physics.This report mainly concentrates on the experiments of nuclear physics with the existing and planned experimental setups such as SHANS,RIBLL1,ETF,CSRe and PISA at HIRFL. 相似文献
1