排序方式: 共有105条查询结果,搜索用时 15 毫秒
1.
提出了在聚乙烯醇存在下,Fe(Ⅲ)-磺基水杨酸-甲基紫三元配合物光度法测定Fe(Ⅲ)的方法.该法灵敏度高(ε=3.44×105L@mol-1@cm-1),选择性及精密度均好,用于水中痕量铁的测定,结果满意. 相似文献
2.
3.
利用压电频移法测定水中的痕量亚硝酸盐 总被引:8,自引:0,他引:8
提出了利用压电频移法测定亚硝酸盐的方法。方法以碘离子与亚硝酸根之间的氧化还原反应为依据,通过测定由反应生成的碘所引起的压电晶体频率的变化,在被萃取水相中亚硝酸盐浓度为0.009 ̄2.3mg/L范围内,频移值与浓度成正比:ΔF=5.8+2.5×10^3C(mg/L),r=0.9901。方法简便,用于天然水中亚硝酸盐的测定,结果令人满意。 相似文献
4.
5.
火焰原子吸收光谱法测定天然水中微量铁的形态 总被引:3,自引:1,他引:3
研究了用抗坏血酸为还原剂,使二价铁离子与邻菲啰啉(phen)形成螯合物,用硝基苯萃取,火焰原子吸收光谱法测定有机相中的铁。方法检出限为1.7ng·ml~(-1),回收率为98.0%~109.6%,线性范围为0~10.0μg·ml~(-1)(原水相),线性相关系数为0.9994。测定结果与ICP-AES法结果对照相对误差小于9.46%。 相似文献
6.
本文研究了银(Ⅰ)-硫脲-四正丁基溴化铵体系的电致化学发光(ECL)。发现在正矩形脉冲下,银对含有硫脲的TBABr溶液的ECL有明显催化作用,银(Ⅰ)的浓度在1.4×10 ̄(-8)~3.5×10 ̄(-6)mol/L范围内与ECL强度呈良好线性关系。检出限为9.0×10 ̄(-9)mol/L相对标准偏差为5%。用于天然水中银的测定,获得较满意的结果。 相似文献
7.
Silica gel-loaded (E)-N-(1-thien-2'-ylethylidene)-1,2-phenylenediamine (TEPDA) phase was synthesized based on physical adsorption approaches. The stability of a chemically modified TEPDA especially in concentrated hydrochloric acid that was then used as a recycling and preconcentration reagent allowed the further uses of silica gel-loaded immobilized TEPDA phase. The application of this silica gel-loaded phase to sorption of a series of metal ions was performed by using different controlling factors such as the pH of the metal ion solution and the equilibration shaking time by the static technique. This difference was interpreted on the basis of selectivity incorporated in these sulfur containing silica gel-loaded TEPDA phases. Hg(Ⅱ) was found to exhibit the highest affinity towards extraction by these silica gel-loaded TEPDA phases. The pronounced selectivity was also confirmed by the determined distribution coefficients (Kd) of all the metal ions, showing the highest value reported for mercury(Ⅱ) extraction by the silica gel immobilized TEPDA phase. The potential applications of the silica gel immobilized TEPDA phase to selective extraction of mercury(Ⅱ) from aqueous solution were successfully accomplished and preconcentration of low concentration of Hg(Ⅱ) (30 pg·mL^-1) from natural tap water with a preconcentration factor of 200 for Hg(Ⅱ) off-line analysis was conducted by cold vapor atomic absorption analysis. 相似文献
8.
主次波长光度法测定天然水中碘 总被引:5,自引:1,他引:5
在溴和甲酸钠存在下,碘与淀粉作用生成蓝色物质,本文根据着色溶液吸光度(A),入射波长(λ)及显色物质浓度(X)的相互关系研究天然水中测定碘的主次波长新光度法,该法具有较高分析精密度,检出限较单波长比色法低,样品分析结果表明:RSD≤4.3%?加标回收率为97%~107%。方法检出限0.001μg/mL。 相似文献
9.
10.
氢化物发生与扇形磁场电感耦合等离子体质谱联用测定天然水中无机硒的价态 总被引:1,自引:0,他引:1
通过对仪器参数、质谱干扰、Se同位素选择、NaBH4浓度、样品酸度、Se?还原条件及氢化反应干扰的评估和优化,建立了自制连续流动氢化物发生装置与扇形磁场电感耦合等离子体质谱联用测定天然水中无机硒价态的分析方法,克服了天然水中多种元素对氢化反应的干扰,解决了不同介质样品中Se?还原率保持95%以上时间短的问题。方法检出限为0.002μg/L,灵敏度为215378 cps/(μg/L),优于同类方法,测定河水和海水中Se?和Se?精密度小于4%,加标回收率在97%~103%之间,可应用于准确测定海水、河口区半咸水、河水等天然水中Se?和Se?浓度。 相似文献