全文获取类型
收费全文 | 148篇 |
免费 | 13篇 |
国内免费 | 8篇 |
专业分类
化学 | 55篇 |
晶体学 | 3篇 |
力学 | 8篇 |
综合类 | 1篇 |
数学 | 11篇 |
物理学 | 91篇 |
出版年
2023年 | 12篇 |
2022年 | 6篇 |
2021年 | 3篇 |
2020年 | 5篇 |
2019年 | 2篇 |
2018年 | 3篇 |
2017年 | 7篇 |
2016年 | 6篇 |
2015年 | 12篇 |
2014年 | 10篇 |
2013年 | 12篇 |
2012年 | 4篇 |
2011年 | 9篇 |
2010年 | 4篇 |
2009年 | 8篇 |
2008年 | 13篇 |
2007年 | 5篇 |
2006年 | 4篇 |
2005年 | 4篇 |
2004年 | 5篇 |
2003年 | 4篇 |
2002年 | 2篇 |
2001年 | 2篇 |
1999年 | 1篇 |
1998年 | 6篇 |
1997年 | 4篇 |
1996年 | 4篇 |
1995年 | 5篇 |
1994年 | 1篇 |
1989年 | 1篇 |
1988年 | 2篇 |
1987年 | 1篇 |
1985年 | 2篇 |
排序方式: 共有169条查询结果,搜索用时 62 毫秒
1.
2.
The dialysis potentials of different collodion membranes with graded pore sizes and electrochemical activities have been measured in dilute aqueous KCl solutions as functions of concentration. It is possible to predict the value of the diffusion potential within a few millivolts on the basis of electrical conductivity data obtained with the same membranes. In general, the measured values are lower than those calculated. It is assumed that this difference is caused by the membranes having a distribution of pore sizes. 相似文献
3.
The power supply for IEF based on features of the Cockcroft‐Walton voltage multiplier (CW VM) is described in this work. The article describes a design of the IEF power supply, its electric characteristics, and testing by IEF analysis. A circuit diagram of the power supply included two opposite charged branches (each consisting of four voltage doublers). The designed CW VM was powered by 230 V/50 Hz alternate current and it generated up to 5 kV and 90 mW at the output. Voltage and current characteristics of the power supply were measured by known load resistances in the range from 10 kΩ to 1 GΩ, which is a common resistance range for IEF strip geometry. Further, the power supply was tested by a separation of a model mixture of colored pI markers using a 175 × 3 × 0.5 mm focusing bed. Automatically limited power load enabled analysis of samples without previous optimization of the focusing voltage or electric current time courses according to sample composition. Moreover, the developed power supply did not produce any intrinsic heat and was easy to set up with cheap and commonly available parts. 相似文献
4.
聚3-己基噻吩(P3HT)以其合成工艺简单、成本低廉的优势,成为有机光伏领域中最具吸引力的电子给体材料之一。然而,目前P3HT: 非富勒烯太阳能电池的光伏性能仍然较差。在本工作中,我们证明了与P3HT: 富勒烯太阳能电池相比,较快的电荷转移态的非辐射衰减速率(Knr)是导致P3HT: 非富勒烯太阳能电池中较低的量子效率和较高的电压损失的原因。然后,我们研究了基于非富勒烯受体ZY-4Cl的太阳能电池的工作机理。研究结果表明与P3HT: 非富勒烯体系相比,P3HT: ZY-4Cl中Knr的降低改善了器件的量子效率,同时降低了电压损失。Knr降低的原因可以部分归因于电荷转移态能量的增加。此外,给体分子和受体分子之间的距离(DA间距)的增大也是Knr减少的重要原因。因此,我们得出结论:为了提高P3HT太阳能电池的性能,需进一步降低器件的Knr,这可通过增加活性层中的DA间距来实现。 相似文献
5.
Cinthia J. Ramirez-Murillo J. Martin de los Santos-Ramirez Victor H. Perez-Gonzalez 《Electrophoresis》2021,42(5):565-587
Dielectrophoretically driven microfluidic devices have demonstrated great applicability in biomedical engineering, diagnostic medicine, and biological research. One of the potential fields of application for this technology is in point-of-care (POC) devices, ideally allowing for portable, fully integrated, easy to use, low-cost diagnostic platforms. Two main approaches exist to induce dielectrophoresis (DEP) on suspended particles, that is, electrode-based DEP and insulator-based DEP, each featuring different advantages and disadvantages. However, a shared concern lies in the input voltage used to generate the electric field necessary for DEP to take place. Therefore, input voltage can determine portability of a microfluidic device. This review outlines the recent advances in reducing stimulation voltage requirements in DEP-driven microfluidics. 相似文献
6.
Threshold switching is a phenomenon where the resistivity of an insulating material changes and the insulator exhibits metallic behavior. This could be explained by phase transformation in oxide materials; however, this behavior is also seen in amorphous insulators. In this study, through an ex-situ experiment using transmission electron microscopy (TEM), we proved that threshold switching of amorphous NbO2 accompanies local crystallization. The change in I–V characteristics after electroforming was examined by evaluating the concentration profile. Atom probe tomography (APT) combined with in-situ TEM probing technique was performed to understand the threshold switching in amorphous NbO2. The local crystallization in amorphous NbO2 was validated by the observed difference in time-of-flight (ToF) between amorphous and crystalline NbO2. We concluded that the slower ToF of amorphous NbO2 (a-NbO2) compared with crystalline NbO2 (c-NbO2) is due to the resistivity difference and trap-assisted recombination. 相似文献
7.
In order to improve the particle collection efficiency of the electrostatic precipitator (ESP), a transverse plate ESP with bipolar discharge electrodes is proposed. The simulations of the velocity distribution have shown that when the inlet velocity is 1 m/s, within the range of 40 mm from electrode plate, the average velocities of windward side and leeward side are less than 0.7 m/s and 0.3 m/s respectively. It is clear that the velocity near the collection electrode plate of this bipolar ESP is much lower than that of the ordinary ESP at the same inlet velocity. This low velocity can lead to higher efficiency for fine dust collection due to the less dust re-entrainment in ESP. It is also found that the average velocities are getting lower when the distance between plates electrodes are greater than 150 mm in accordance with the simulations. The voltage current characteristics of the bipolar ESP are superior to the ordinary ESP. The pressure drop of the bipolar ESP is about 30% higher than that of the ordinary one. The dust penetration of the bipolar ESP is about 54% less than that of the ordinary ESP when the sintering dust with 25.405 μm mass median diameter is used as the test particulate under the condition of the electric field from 2.1 kV/cm to 3.2 kV/cm and the velocity from 1.0 m/s to 1.5 m/s. 相似文献
8.
9.
电压敏感染料di-4-ANEPPS的光谱研究 总被引:3,自引:3,他引:0
实验研究了电压敏感染料di-4-ANEPPS在家兔心肌组织中的吸收光谱和荧光光谱特性。结果表明,含染料组织的光吸收普遍大于对照组,在450~550 nm波段吸收谱差异更明显;染料在心室组织中的最大吸收峰为(479.75±0.44) nm。通过测量含染料心脏不同部位的荧光光谱,首次发现心室组织、心房组织和主动脉的最大荧光峰位有一定差异,其相对荧光强度则与染料的分布浓度有关。根据三维和二维荧光光谱分别确定了含染料心房和心室组织的最佳荧光激发波长和荧光测定波长。利用心房和心室组织的静息电位差,在不同波长激发光下测量了染料的荧光光谱移动,确定了光标测量实验的最佳激发光和相应荧光检测波长范围。这些研究结果为心脏光学标测系统的设计提供了理论依据。 相似文献
10.
《Current Applied Physics》2020,20(7):883-887
Voltage control magnetism is one of the most energy efficient pathway towards magnetoelectric (ME) device. Ionic liquid gating (ILG) method has already shown impressive manipulation power at the IL/electrode interface to influence the structure, orbital as well as spin of the electrode materials. As key material in anisotropy magnetoresistance sensor and spin valve heterostructure, the permalloy Ni0.81Fe0.19 was utilized as the electrode to investigate the ILG induced magnetic anisotropy change. In this work, we realized magnetic anisotropy control in Au/[DEME]+[TFSI]-/Ni0.81Fe0.19 (2.5 nm)/Ta heterostructure via ILG caused electrostatic doping. This is evidenced in situ reversible ferromagnetic field (Hr) shift with electron spin resonance (ESR) spectrometer. Aiming at the question whether the charge accumulation at the ionic liquid interface is the main control mechanism at low voltage, we carefully tested the relationship between the change of resonance field and the amount of surface charge. It was found that these two had a good linear relationship between −1 V and +1 V. Defining the linear parameter as A whose value is 28.7 mT m2/Col. Unlike previously reported chemical regulation of Co, this article used ionic liquids to physically regulate NiFe, which has not been studied in the previous ionic liquid regulation. And NiFe has a narrower resonance line width for easy reference to microwave devices. In addition, It also has a stronger ferromagnetic signal than Co, which can be more easily detected as a sensor device. Therefore, this system is more promising. The ILG control NiFe may lead to a new kind of magnetoelectric sensor devices and path a new way to low energy consumption spintronics. 相似文献