The ESTU began operation in 1988 and achieved the design voltage of 20 MV in 1990. Since that time, improvements to the gas
handling system, negative ion injector, accelerator terminal and control system have greatly increased its capability and
reliability. Today, the ESTU can efficiently produce an extensive assortment of stable ions at wide-ranging energies in support
of low-energy nuclear physics. 相似文献
The bunching system of the ATLAS positive ion injector (PII) has been improved by relocating the harmonic buncher to a point
significantly closer to the second stage sine-wave buncher and the injector LINAC. The longitudinal optics design has also
been modified and now employs a virtual waist from the harmonic buncher feeding the second stage sine-wave buncher. This geometry
improves the handling of space charge for high-current beams, significantly increases the capture fraction into the primary
rf bucket and reduces the capture fraction of the unwanted parasitic rf bucket. Total capture and transport through the PII
has been demonstrated as high as 80% of the injected dc beam while the population of the parasitic, unwanted rf bucket is
typically less than 3% of the total transported beam. To remove this small residual parasitic component a new traveling-wave
transmission-line chopper has been developed reducing both transverse and longitudinal emittance growth from the chopping
process. This work was supported by the U.S. Department of Energy under contract W-31-109-ENG-38. 相似文献
The adverse effects of injection solvent strength on microbore packed column SFC band broadening are demonstrated and a solventless injection system that eliminates these effects is introduced. The injection system removes solvent in a GC-like manner using a retention gap and an on-column capillary GC syringe. The analyte is delivered to the analytical column in a solvent-free plug of supercritical fluid mobile phase. 相似文献
The present paper describes constructional details and evaluations of an at-column injector for capillary GC. Injections were made via a sample loop on a 0.32 mm i.d. capillary column. Two rotary valves were employed to allow a wash of the sample loop and a backflush of the transfer line. Repeatability, calculated from absolute area counts for n-alkanes was between 0.3–1% RSD, for injected sample volumes between 5 and 100 μl. Promising results were also obtained with syringe-based injections on narrow bore (100 μ i.d.) columns. Repeatability on the basis of normalized area counts was in the order of 0.1–0.2% RSD, while solvent tailing was practically absent. 相似文献
Summary A new simplified version of a closed on-column injector is introduced. Because of its design isobaric injection conditions do not have to be followed and a wide range of injection temperatures above the boiling point of the sample solvent can be chosen for on-column injections in capillary gas chromatography. Also, when following certain basic injection rules, injections of large sample volumes (20 l or more) give accurate and reproducible results without further problems.Presented at the 17th International Symposium on Chromatography, September 25–30, 1988, Vienna, Austria. 相似文献
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.
An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ1=μ2=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. 相似文献
As most sample liquids tend to pass through an empty injector insert at a speed which is too high to enable complete evaporation, movement of the liquid must be arrested before it reaches the column entrance. Stopping the liquid means deposition on to a surface; this, however, is possible only after the temperature of the surface has been cooled to (or below) the boiling point of the liquid (solvent). The performance of different means of stopping the liquid has been tested visually (by the method described in Part 2). Baffles on the wall of the injector insert had hardly any effect on evaporation: the band of liquid leaving the syringe needle performed a perfect slalorn around them. The inverted cup proved more efficient, but the best performance was obtained from a light plug of glass wool: owing to its low thermal mass, the first fibers to be met by the liquid are immediately cooled to the solvent boiling point, allowing the liquid to wet it. The sample liquid is sucked up by the glass wool, from where the sample evaporates relatively slowly, often over a period of several seconds. 相似文献
The light intensity measurement and image visualization of multi-hole injection spray due to different hole arrangements and hole numbers were investigated. The light intensities and behavior characteristics of the GDI spray were analyzed through the axial and diagonal spray penetration, cone angle, and spray area from the spray images by using the image visualization system and image analysis system. The atomization performance of GDI injectors was analyzed by the local and overall Sauter mean diameter (SMD) measurement. 相似文献