排序方式: 共有87条查询结果,搜索用时 15 毫秒
1.
A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine tripdiolide in human whole blood using dexamethasone acetate as an internal standard (I.S.). Liquid-liquid extraction with ethyl acetate was used to isolate them from the biological matrix. Detection was performed on a mass spectrometer coupled with a negative atmospheric pressure chemical ionization (APCI) in the multiple-reaction monitoring (MRM) mode. The calibration curve was linear (r2 = 0.9973) in the concentration range of 0.5-100.0 ng/mL in human whole blood with a lower limit of quantification of 0.5 ng/mL. Intra-day and inter-day relative standard deviations (R.S.D.s) were less than 7.0 and 10.1%, respectively. Extraction recoveries of tripdiolide ranged from 80.5 to 90.1%. This assay can be used to determine trace tripdiolide in human whole blood. 相似文献
2.
M.C. Menet C.H. Cottart M. Taghi V. Nivet-Antoine D. Dargère F. Vibert O. Laprévote J.-L. Beaudeux 《Analytica chimica acta》2013
Resveratrol is a polyphenol that has numerous interesting biological properties, but, per os, it is quickly metabolized. Some of its metabolites are more concentrated than resveratrol, may have greater biological activities, and may act as a kind of store for resveratrol. Thus, to understand the biological impact of resveratrol on a physiological system, it is crucial to simultaneously analyze resveratrol and its metabolites in plasma. This study presents an analytical method based on UHPLC-Q-TOF mass spectrometry for the quantification of resveratrol and of its most common hydrophilic metabolites. The use of 13C- and D-labeled standards specific to each molecule led to a linear calibration curve on a larger concentration range than described previously. The use of high resolution mass spectrometry in the full scan mode enabled simultaneous identification and quantification of some hydrophilic metabolites not previously described in mice. In addition, UHPLC separation, allowing run times lower than 10 min, can be used in studies that requiring analysis of many samples. 相似文献
3.
4.
5.
蛋白质的还原-烷基化是蛋白质酶切中的重要步骤,常用的烷基化试剂是碘乙酰胺(IAA),但是IAA除了和半胱氨酸发生反应,也可能和其他多种氨基酸发生副反应。我们模拟常规的酶切条件,系统地研究了蛋白质真实酶切时所有酶切肽段发生烷基化的情况。结果表明,多种氨基酸可以发生烷基化,其趋势为:半胱氨酸>肽段N端氨基酸>天冬氨酸>谷氨酸>组氨酸>天冬酰胺>赖氨酸>酪氨酸,同时也发现同一肽段上的氨基酸烷基化具有排他性和聚集性。根据定性结果,采用质谱多反应监测(MRM)技术对多个肽段进行了定量分析,评估了过烷基化对蛋白质定量分析的影响。该研究结果表明,过量的烷基化修饰对蛋白质的定性与定量分析都可能产生较大影响。在蛋白质组学研究的样本处理流程中,应避免样本的过烷基化。 相似文献
6.
建立了一种快速、灵敏、准确的同时测定牛蛙全血中双酚A、己烯雌酚、己二烯雌酚、己烷雌酚、4-叔辛基酚和4-壬基酚等6种酚类环境雌激素的分散固相萃取-超快速液相色谱-串联质谱(dSPE-UFLC-MS/MS)分析方法。牛蛙全血样品经含0.1%(v/v)甲酸的甲醇溶液沉淀蛋白后,利用自制的氨基功能化Fe3O4磁性高分子复合微粒(EDA-MPs)作为dSPE吸附剂进行净化,着重考察了沉淀剂、吸附净化时间、吸附剂用量等因素对6种酚类环境雌激素回收率的影响。采用Shim-pack XR-ODSII(100 mm×2.0 mm, 2.2 μm)反相液相色谱柱进行分离,在电喷雾离子源(ESI)负离子多反应监测(MRM)模式下进行检测。结果表明: 6种酚类环境雌激素在0.5~100.0 μg/L范围内具有良好的线性关系(r2≥0.9996),方法的定量限(信噪比大于10)为0.075~0.40 μg/L,方法的精密度为0.6%~6.3%,空白样品中3个不同水平的添加回收率为95.0%~110.0%。本方法适用于牛蛙全血中6种酚类环境雌激素的同时测定。 相似文献
7.
J. Manjunath Swamy Narendra Kamath Anil Kumar Radha Shekar Nuggehally R. Srinivas Fjalar Kristjansson 《Biomedical chromatography : BMC》2010,24(5):528-534
Sensitivity enhancement via summation of multiple MRM transition pairs is gaining popularity in tandem mass spectrometric assays. Numerous validation experiments describing the assays for two model substrates, clopidogrel and ramiprilat, were performed. The quantitation of clopidogrel was achieved by the summation of transition pairs m/z 322.2 to m/z 212.0 and m/z 322.2 to m/z 184.0, while that of ramiprilat was achieved by the summation of transition pairs m/z 389.2 to m/z 206.1 and m/z 389.2 to m/z156.1. The use of summation approach achieved sensitivities of >2 fold for both compounds as compared with the reported single MRM transition pair assays. The validation experiments addressed some important assay development issues, such as: (a) lack of impact of matrix effect; (b) unequivocal verification of the percentage contribution of each MRM transition pair towards sensitivity; (c) sensitivity enhancement factor achieved by summation approach of MRM transition pairs; and (d) accurate prediction of quality control samples using summation approach vs a single MRM transition pair. In summary, the appropriateness of using two MRM transition pairs for quantitation was demonstrated for both clopidogrel and ramiprilat. Additionally, pharmacokinetic application of the MRM transition pair assays using a summation approach was established for the two compounds. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
8.
A method for fast and selective determination of the main triterpenic compounds present in olive leaves — oleanolic, ursolic and maslinic acids as triterpenic acids and, uvaol and erythrodiol as triterpenic dialcohols — is reported here. Quantitative isolation of the analytes has been accomplished in 5 min by microwave assistance using ethanol as extractant. Due to the medium polarity of triterpenic acids and dialcohols, different ethanol-water ratios were tested in order to select the optimum extractant composition for their solubilisation. Microwave assistance provided a significant shortening of the leaching time as compared to conventional procedures by maceration, which usually requires at least 5 h. After extraction, determination was carried out by liquid chromatography-tandem mass spectrometry (LC-MS-MS) with a triple quadrupole (qQq) mass detector without any clean-up step prior to chromatographic analysis. Highly selective identification of triterpenes was confirmed by multiple reaction monitoring (MRM) using the most representative transitions from the precursor ion to the different product ions, while the most sensitive transitions were used for MS-MS quantitation. Total analysis performed in 25 min enables the characterization of a fraction with particular interest in the pharmacological area. 相似文献
9.
Anneli Kruve Riin Rebane Karin Kipper Maarja-Liisa Oldekop Hanno Evard Koit Herodes Pekka Ravio Ivo Leito 《Analytica chimica acta》2015
This is the part I of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS/MS) detection in LC (as opposed to the “conventional” detectors). The Part I briefly introduces the principles of operation of LC–MS (emphasizing the aspects important from the validation point of view, in particular the ionization process and ionization suppression/enhancement); reviews the main validation guideline documents and discusses in detail the following performance parameters: selectivity/specificity/identity, ruggedness/robustness, limit of detection, limit of quantification, decision limit and detection capability. With every method performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to determine it, specifically in the case of LC–MS methods. 相似文献
10.
Jana Beinhauer Liangqiao Bian Hui Fan Marek Šebela Maciej Kukula Jose A. Barrera Kevin A. Schug 《Analytica chimica acta》2015
Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL−1, and demonstrated good linearity of R2 from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL−1. Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified. 相似文献