首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   92篇
  免费   2篇
  国内免费   7篇
化学   91篇
晶体学   2篇
综合类   1篇
物理学   7篇
  2024年   1篇
  2023年   2篇
  2022年   6篇
  2021年   9篇
  2020年   6篇
  2019年   9篇
  2018年   3篇
  2017年   1篇
  2016年   1篇
  2015年   2篇
  2014年   3篇
  2013年   8篇
  2012年   7篇
  2011年   5篇
  2010年   2篇
  2009年   1篇
  2008年   3篇
  2007年   7篇
  2006年   4篇
  2005年   2篇
  2004年   4篇
  2002年   3篇
  2001年   2篇
  2000年   2篇
  1999年   3篇
  1998年   1篇
  1994年   1篇
  1993年   1篇
  1991年   1篇
  1984年   1篇
排序方式: 共有101条查询结果,搜索用时 31 毫秒
1.
Differential scanning calorimetry (DSC), supported by hot stage microscopy, IR spectroscopy and X-ray powder diffractometry, was used to investigate the characteristics of the solid phases of mefenamic, niflumic, and flufenamic acids and of paracetamol, before and after equilibration with saturated solutions in different solvents. Mixtures of Lewis base (dioxane and ethyl acetate) and amphiprotic solvents (ethanol and water) were prepared for evaluating the influence of both nature and polarity of the solvents. Solid-state analysis performed on the original samples (commercial products) made it possible to establish that paracetamol, mefenamic acid and flufenamic acid were in their respective Form I. No polymorphic modifications are known for niflumic acid. Paracetamol, niflumic and mefenamic acids did not show any change after equilibration with the various solvents or solvent mixtures, regardless of their different chemical nature. In contrast, DSC, IR and X-ray analyses revealed the partial recrystallization of flufenamic acid into its polymorphic Form III in solid phases at equilibrium with ethanol, ethyl acetate and their blends, as well as in dioxane-water mixtures containing 30 to 100% dioxane and in ethanol-water mixtures with a water content less than 50%. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   
2.
A polarographic procedure is described for the determination of paracetamol (acetaminophen) and salicylamide after treatment with nitrous acid. The different experimental parameters affecting the derivatization process and the polarographic analysis were studied. The derivatization products were found to be reduced at the dropping mercury electrode over the whole pH range in Britton-Robinson buffers. At pH 7.0, well defined diffusion-controlled cathodic waves were produced for both compounds. Plots of limiting current vs. concentration were linear over the ranges 0.05–0.75 and 0.25–1.5mM for paracetamol and salicylamide, respectively, in the d.c. mode, with minimum detectability of 2.5 × 10–6 and 1.25 × 10–5 M, respectively. The procedure was applied to the analysis of some pharmaceutical dosage forms and the results were in good agreement with those obtained by official and compendial methods.  相似文献   
3.
Polymorphism of paracetamol   总被引:1,自引:0,他引:1  
The thermodynamic relationship between crystal modifications of paracetamol was studied by alternative methods. Temperature dependence of saturated vapor pressure for polymorphic modifications of the drug paracetamol (acetaminophen) was mea sured and thermodynamic functions of the sublimation process calculated. Solution calorimetry was carried out for the two modifications in the same solvent. Thermodynamic parameters for sublimation for form I (monoclinic) were found: ΔG sub298=60.0 kJ mol−1; ΔH sub298=117.9±0.7 kJ mol−1; ΔS sub298=190±2 J mol−1 K−1. For the orthorhombic modification (form II), the saturated vapor pressure could only be studied at 391 K. Phase transition enthalpy at 298 K, ΔH tr298(I→II)=2.0±0.4 kJ mol−1, was derived as the difference between the solution enthalpies of the noted polymorphs in the same solution (methanol). Based on ΔH tr298 (I→II), differences between temperature dependencies of heat capacities of both modifications and the vapor pressure value of form II at 391 K, the temperature dependence of saturated vapor pressure and thermodynamic sublimation parameters for modification II were also estimated (ΔG sub298=56.1 kJ mol−1; ΔH sub298=115.9±0.9 kJ mol−1; ΔS sub298=200±3 J mol−1 K−1). The results indicate that the modifications are monotropically related, which is in contrast to findings recently reported found by classical thermochemical methods.  相似文献   
4.
Studies carried out by X-ray and thermal analysis confirmed that acetaminophen (paracetamol), declared by the manufacturers as an Active Pharmaceutical Ingredient (API), was present in all studied medicinal drugs. Positions of diffraction lines (2θ angles) of the studied drugs were consistent with standards for acetaminophen, available in the ICDD PDF database Release 2008. |Δ2θ| values were lower than 0.2°, confirming the authenticity of the studied drugs. Also, the values of interplanar distances dhkl for the examined samples were consistent with those present in the ICDD. Presence of acetaminophen crystalising in the monoclinic system (form I) was confirmed. Various line intensities for API were observed in the obtained diffraction patterns, indicating presence of the preferred orientation of the crystallites in the examined samples. Thermal analysis of the studied substances confirmed the results obtained by X-ray analysis. Drugs containing only acetaminophen as an API have melting point close to that of pure acetaminophen. It was found that presence of other active and auxiliary substances affected the shapes and positions of endothermal peaks significantly. A broadening of endothermal peaks and their shift towards lower temperatures were observed accompanying an increase in the contents of additional substances being “impurities” in relation to the API. The results obtained by a combination of the two methods, X-ray powder diffraction (XRPD) and differential scanning calorimetry/thermogravimetry (DSC/TGA), may be useful in determination of abnormalities which can occur in pharmaceutical preparations, e.g., for distinguishing original drugs and forged products, detection of the presence of a proper polymorphic form or too low content of the active substance in the investigated drug.  相似文献   
5.
A novel ecofriendly, cost and time saving high‐performance thin‐layer chromatographic method was developed and validated for simultaneous determination of metoclopramide, ergotamine, caffeine, and paracetamol in bulk and pharmaceutical formulation. The separation was carried out on silica gel plates, using ethyl acetate:ethanol:ammonia (9:1:0.1, v/v/v) as a developing system. Ultraviolet detection was carried out at 272 nm. The resulting retention times were 0.15, 0.36, 0.49, and 0.74 min for metoclopramide, ergotamine, caffeine, and paracetamol, respectively. The greenness profile assessment was achieved to the proposed method to evaluate its greenness characters to the environment with acceptable results. Validation parameters were checked according to International Conference of Harmonization guidelines to achieve the international requirements for quality control analysis of the proposed drugs.  相似文献   
6.
7.
Demet Uzun 《Electroanalysis》2021,33(7):1699-1706
In this present study, to determine paracetamol, an electroanalytical method is presented using differential pulse voltammetry (DPV) at 3-amino-4H-1,2,4-triazole (3AT) coated glassy carbon (GC) electrode. The electrochemical characterization and electron transfer behavior of this prepared electrode in the mixture of K4[Fe(CN)6]/K3[Fe(CN)6] contains 0.1 M KCl was confirmed by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. Furthermore, scanning electron microscopy (SEM) was used to observe morphological structures of the bare and modified surfaces. The effect of pH was studied on the redox reaction of paracetamol in phosphate buffer in the range of pH 3.0–9.0. The limit of detection was 0.043 μM (3 s/m) for 3AT-GC electrode. The developed electrode was successfully utilized in pharmaceutical samples.  相似文献   
8.
建立了同时测定复方阿司匹林制剂中阿司匹林、对乙酰氨基酚、咖啡因及降解产物水杨酸的大口径毛细管气相色谱法。在HP-1大口径色谱柱上直接进样,无需衍生化处理,所测组分与内标物2 min内达到基线分离。各组分在其线性范围内线性关系良好(相关系数均高于0.999),检出限分别为10.0μg/L、5.0μg/L、1.0μg/L和1.0μg/L。经样品测定,平均回收率为97.46%~101.24%。该法简便、快速、准确、重现性好,可用于复方阿司匹林制剂的质量控制。  相似文献   
9.
The analytical performance of the clay paste electrode and graphene paste electrode was compared using square wave voltammetry (SWV) and cyclic voltammetry (CV). The comparison was made on the basis of a paracetamol (PA) determination on both working electrodes. The influence of pH and SWV parameters was investigated. The linear concentration ranges were found to be 6.0 × 10−7–3.0 × 10−5 and 2.0 × 10−6–8.0 × 10−5 mol L−1 for clay paste electrode (ClPE) and graphene paste electrode (GrPE), respectively. The detection and quantification limits were calculated as 1.4 × 10−7 and 4.7 ×10−7 mol L−1 for ClPE and 3.7 × 10−7 and 1.2 × 10−6 mol L−1 for GrPE, respectively. Developed methods were successfully applied to pharmaceutical formulations analyses. Scanning electron microscopy and energy-dispersive X-ray spectroscopy were used to characterize ClPE and GrPE surfaces. Clay composition was examined with wavelength dispersive X-ray (WDXRF).  相似文献   
10.
基于常压质谱的直接、快速、无需样品预处理检测的优势,该文拓展了其在药物质检领域的应用。采用自行搭建的解析电喷雾(DESI)装置,对常用感冒药对乙酰氨基酚片进行快速质谱检测,无需样品预处理,直接获得药片中有效成分的分子结构信息。为克服基质差异对定量分析的影响,以淀粉为基质构建对乙酰氨基酚模拟药片,在优化的基础上进行定量实验。针对实际药片中高浓度对乙酰氨基酚检测的需要,研究了其在较高浓度范围的定量关系,结果显示,方法对0.35~4.52 mg/mm^2范围内的对乙酰氨基酚具有较好的线性关系(r^2=0.9982),定量下限为1.903 ng/mm^2,检出限为0.237 ng/mm^2,加标回收率为102%~114%。对3种市售的对乙酰氨基酚片进行直接检测,与厂家提供的标准数据相比,相对标准偏差(RSD)为7.2%~12%,表明方法具有较好准确度。该工作很好地证明了DESI-MS在药品快检中的优势,从而为药品质检提供了潜在的高效、可靠的检测手段。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号