The investigative results of modulated pulse output from an LD end-pumped passively Q-switched intracavity-frequency-doubling Nd∶YVO4/KTP laser with Cr4+∶YAG saturable absorber are presented. The numerical stimulations of these modulated pulses are carried out basing on the rate equations. It indicated that the modulations are attribute to the frequency beating of two eigenstates of the resonant polarized modes. The theoretical calculations are in good agreement with the experimental observations. 相似文献
The extents of the protective effects of coating films on the surface of crystals were determined. Three different samples
were made with different quantities of coating fluid (Sepifilm LP 010 in 10% aqueous solution). Since the atomizing rate was
constant, the coating time increased in parallel with the volume of coating fluid applied. The direct measurement of film
thickness and smoothness is very difficult, and therefore indirect methods were used. Dimenhydrinate was chosen as model drug;
this is a heat-sensitive antihistamine with a low melting point. This temperature can be reached during the tableting process.
The behaviour of samples on exposure to heat was examined by differential scanning calorimetry. The water uptakes of the samples
were determined with an Enslin apparatus. Plasticity was studied with an instrumented tablet machine. These indirect methods
(thermal conductivity, water uptake and plasticity measurements) revealed connections between the results of the various experiments.
An overlong coating time decreased the protective effect of the coating film.
This revised version was published online in August 2006 with corrections to the Cover Date. 相似文献
This paper describes a compulsorily phase locked differential interferometer using an orthogonally polarized light source of a modulated LD with high extinction ratio to reduce non-linearity of the interferometer caused by polarization cross-talk. The current modulated LD is used as a light source to make the interferometer compact and for the scanning phase of the interferometer. The interferometer is operated compulsorily at the maximum inclination point of the fringe intensity curve by fringe scanning and an electric system. A Wollaston prism of high extinction ratio (50 dB) is used to combine the polarizing beams and to make the polarization cross-talk very small. In one light source the polarized output beams are on the same propagation axis; in the other they have a small crossing angle (2.5 mrad ∼ 10 mrad) to completely exclude non-linearity of the interferometer causded by polarization cross-talk. Using jets of a gas mixture of nitrogen and ethylene, this interferometer was demonstrated to be useful in detecting the photothermal effect of a photothermal velocimeter under phase fluctuation in a turbulent flow. 相似文献
This research aimed to reduce the variability on the data obtained from differential scanning calorimetric (DSC) analysis of the isothermal crystallization kinetics of cocoa butter.
To enable transformation of the DSC crystallization peak to a sigmoid crystallization curve, the DSC peak area has to be integrated. Usually, the start and end points of the crystallization peak are determined visually. The result of this visual determination appeared to be very much dependent on the operator, but also differed considerably when the same operator performed the integration several times. By proposing an objective calculation algorithm to determine the start and end points of integration, the variability caused by the operator during the integration procedure could be eliminated. Furthermore, sample preparation and the DSC heating protocol to melt the sample prior to crystallization were studied. Three heating protocols (65 °C for 15 min, 65 °C for 30 min and 80 °C for 15 min) were compared and it was shown that holding at 65 °C for 15 min was sufficient to eliminate any influence of sample history. Two different sample preparation procedures were compared and it appeared that a change in sample preparation procedure had a significant influence on the measured crystallization process. It is thus important to keep this method constant to eliminate the variability caused by it. 相似文献