首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   2篇
  国内免费   3篇
化学   32篇
晶体学   1篇
物理学   4篇
  2022年   1篇
  2021年   2篇
  2020年   1篇
  2018年   2篇
  2015年   3篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2010年   4篇
  2009年   2篇
  2008年   4篇
  2007年   3篇
  2006年   4篇
  2005年   2篇
  2004年   2篇
  2002年   1篇
排序方式: 共有37条查询结果,搜索用时 93 毫秒
1.
Five new optically active aromatic poly(amide-imide)s (PAIs) 5a–e were prepared from a direct polycondensation reaction of a new diacid of N,N′-(bicyclo[2,2,2]oct-7-ene-2,3,5,6-tetra carboxylic)-bis-L-isoleucine 3 with various aromatic diamines 4a–e in a medium consisting of triphenyl phosphite (TPP), calcium chloride (CaCl2), pyridine (Py) and N-methyl-2-pyrrolidone (NMP). The polycondensation reaction produced a series of novel poly(amid-imide)s 5a–e in quantitative yields with inherent viscosities of 0.39–0.51 dL/g. The resulting polymers were fully characterized by means of 1H-NMR, FT-IR spectroscopy, elemental analyses, inherent viscosity, solubility test, specific rotation and thermal properties of them were investigated using TGA/DTG and differential scanning calorimeter (DSC). The diacid 4 was synthesized by the condensation reaction of bicyclo[2,2,2]oct-7-ene-2,3,5,6- tetracarboxylic dianhydride 1 with L-isoleucine 2 in acetic acid solution.  相似文献   
2.
4-Hydroxy isoleucine is one of the potent hypoglycemic active constituents of fenugreek seeds. A method capable of reducing biological interferences is required for bioavailability studies. An isocratic separation of 4-hydroxy isoleucine from endogenous interferences was achieved in ZIC-cHILIC column using 0.1% formic acid in water and acetonitrile (20:80, % v/v) pumped at 0.5 ml/min. Quantification was performed in multiple reaction monitoring mode using the transitions of m/z 148.1→102.1 and m/z 276.1→142.2 for 4-hydroxy isoleucine and homatropine (as internal standard), respectively. After full method validation, 4-hydroxy isoleucine levels in human plasma and commercial fenugreek formulations were determined. This method showed good linearity in the range of 50–2000 ng/mL. Intra- and interday accuracies were in the range of 90.64–109.0% and precision was <4.82% CV. The mean (SD) plasma concentration of 4-hydroxy isoleucine in healthy individuals at 2 h after oral administration of fenugreek tablet was found to be 1590 (260) ng/mL. Half of marketed formulations were found to contain <0.05% of 4-hydroxy isoleucine content. We developed a rapid hydrophilic interaction liquid chromatography–tandem mass spectrometry method for analysis of 4-hydroxy isoleucine in human plasma. This method can be applied directly to conduct the clinical pharmacokinetics studies of 4-hydroxy isoleucine in human population.  相似文献   
3.
利用表面增强拉曼光谱(SERS)技术研究了在粗糙化银电极表面吸附的异亮氨酸自组装单层膜结构及其表面性质随溶液酸碱性和电极电位改变的特征.研究结果表明溶液pH值的变化并没有显著改变异亮氨酸分子在银电极表面以去质子化羧基吸附为主的特征.借助于高氯酸根离子这一SERS光谱探针,对异亮氨酸单分子膜的表面酸碱性质进行了表征和分析.而就电位改变对该单分子膜结构的影响而言,在所研究的电位范围内,单分子膜中的异亮氨酸分子是通过去质子化羧基与氨基两个位点而吸附的,且吸附作用随电位负移而呈现有规律的变化.  相似文献   
4.
The metabolic profiling of kiwifruit (Actinidia deliciosa, Hayward cultivar) aqueous extracts and the water status of entire kiwifruits were monitored over the season (June-December) using nuclear magnetic resonance (NMR) methodologies. The metabolic profiling of aqueous kiwifruit extracts was investigated by means of high field NMR spectroscopy. A large number of water-soluble metabolites were assigned by means of 1D and 2D NMR experiments. The change in the metabolic profiles monitored over the season allowed the kiwifruit development to be investigated. Specific temporal trends of aminoacids, sugars, organic acids and other metabolites were observed.The water status of kiwifruits was monitored directly on the intact fruit measuring the T2 spin-spin relaxation time by means of a portable unilateral NMR instrument, fully non-invasive. Again, clear trends of the relaxation time were observed during the monitoring period.The results show that the monitoring of the metabolic profiling and the monitoring of the water status are two complementary means suitable to have a complete view of the investigated fruit.  相似文献   
5.
Crystals of maleates of three amino acids with hydrophobic side chains [L‐leucenium hydrogen maleate, C6H14NO2+·C4H3O4, (I), L‐isoleucenium hydrogen maleate hemihydrate, C6H14NO2+·C4H3O4·0.5H2O, (II), and L‐norvalinium hydrogen maleate–L‐norvaline (1/1), C5H11NO2+·C4H3O4·C5H12NO2, (III)], were obtained. The new structures contain C22(12) chains, or variants thereof, that are a common feature in the crystal structures of amino acid maleates. The L‐leucenium salt is remarkable due to a large number of symmetrically non‐equivalent units (Z′ = 3). The L‐isoleucenium salt is a hydrate despite the fact that L‐isoleucine is a nonpolar hydrophobic amino acid (previously known amino acid maleates formed hydrates only with lysine and histidine, which are polar and hydrophilic). The L‐norvalinium salt provides the first example where the dimeric cation L‐Nva...L‐NvaH+ was observed. All three compounds have layered noncentrosymmetric structures. Preliminary tests have shown the presence of the second harmonic generation (SGH) effect for all three compounds.  相似文献   
6.
In many viruses, pH-responsive coiled-coil domains in the specific fusion proteins play important roles in membrane fusion and the infection of viruses into host cells. To investigate the relationship between the conformational change of the coiled coil and the fusion process, we have introduced a de novo designed polypeptide as a model system of the coiled-coil domain. This system enables the systematic study of the dynamics of pH-responsive coiled-coil polypeptide-membrane interactions. First, we designed and synthesized pH-responsive isoleucine-zipper triple-stranded coiled-coil polypeptides. Then the relationship between the pH-induced conformational change of the polypeptide and the membrane's interactive properties was studied by physicochemical methods. Structural changes in the designed polypeptides were examined by means of circular dichroism measurements. And finally, the behavior of the membrane fusion was investigated by leakage of liposomal contents, turbidity analysis, dynamic light scattering, and lipid mixing experiments. Our data show that coiled-coil formation under acidic pH conditions enhances polypeptide-induced membrane fusion. The results in this study demonstrate that an artificial membrane fusion system can be constructed on a molecular level by the use of a pH-responsive isoleucine-zipper triple-stranded coiled-coil polypeptide.  相似文献   
7.
A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.  相似文献   
8.
Enzymes, receptors, and carrier proteins discriminate between enantiomers of natural and synthetic chemicals. Whereas the structural details of this phenomenon have been investigated in enzymes and receptors, much less is known for carrier proteins of hydrophobic ligands, particularly concerning the contribution of asymmetric centers in the side chains of amino acids to chirally selective binding. Working with a pig odorant-binding protein, we have found that the replacement of either one or both isoleucine residues in the binding pocket by leucines abolishes discrimination of menthol and carvone enantiomers. The results indicate that isoleucines are crucial for chiral discrimination of hydrophobic ligands, and that asymmetry in the side chain may be as important as the overall asymmetry of the protein. The results provide suggestions and guidelines for improving chiral selectivity of binding proteins and enzymes, with consequent applications in the production of enantiomerically pure drugs.  相似文献   
9.
The most stable charge-solvated (CS) and zwitterionic (ZW) structures of sodiated and cesiated leucine and isoleucine were studied by density functional theory methods. According to the Boltzmann distribution in gas phase, both forms of LeuNa+ and IleNa+ exist, but in LeuCs+ and IleCs+, the ZW forms are dominant. Results for the sodiated compounds are consistent with the relationship found between decrease in relative stability of CS versus ZW form and aliphatic amino acid side chain length. The observed degeneracy in energy for IleNa+ conformers is at odds with kinetic method results. Additional calculations showed that kinetic method structural determinations for IleNa+ do not reflect relative order of populations in the lowest energy conformers. Since complexation of cationized amino acids into ion-bound dimers disfavors ZW structure by approximately 8 kJ mol(-1), it is suggested that for energy close conformers of sodium-cationized amino acids, the kinetic method may not be reliable for structural determinations.  相似文献   
10.
赵华  李晶  袁佩  邱宗荫 《分析化学》2006,34(10):1433-1436
建立了用邻苯二甲醛和N-乙酰-L-半胱氨酸为柱前手性衍生化试剂,反相高效液相色谱法分离生物样品中异亮氨酸4个异构体,并以电喷雾电离质谱(ESI-MS)进行检测的高灵敏度的分析方法。对D-Ile、D-al-lo-Ile和L-allo-Ile检测的线性范围为5~500ng,相关系数分别为0.9967、0.9968和0.9993;对L-Ile检测的线性范围为50ng~5μg;相关系数为0.9990。在正常人血浆中检测出了L-Ile(204(113.8mg/L)和L-allo-Ile(1·16±0.71mg/L),在正常人尿样中检测出了L-Ile(6.10±2.24mg/L)和D-allo-Ile(0.53±0.17mg/L)。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号