A chemiluminescence method for the determination of folic acid by the sodium hypochlorite–folic acid–semicarbazide hydrochloride system with a new flow injection technique has been established. The new method can perform simple, sensitive and rapid determinations of folic acid. The response to the concentration of folic acid, in the range of 1.0×10−75.0×10−5 g/ml, is linear. The relative standard deviation of the method is 2.3% (Cs=4.0×10−6 g/ml, n=11). The detection limit is 2.7×10−8 g/ml. This method is suitable for automatic and continuous analysis, and has been successfully tested for the determination of folic acid in a folic acid tablet. 相似文献
2-Substituted benzoxazole and benzothiazole were synthesized from condensation of aldehyde and 2-aminophenol or 2-aminothiophenol via a one-pot process using diethyl bromo phoshonate and tert-butyl hypochlorite. 相似文献
The first ratiometric fluorescent probe for hypochlorite has been developed through regulation of the electron‐withdrawing ability of the electron acceptor in an intramolecular charge‐transfer (ICT) system by a deoximation reaction (see figure; EWG=electron‐withdrawing group).
In France, hot water quality control inside buildings is occasionally assured by disinfection treatments using sodium hypochlorite (between 0.5 and 1 ppm residual free chlorine). This disinfectant is a strong oxidizer and it could interact with metallic and polymer pipes used in hot water systems. To assess the long-term performance of these pipes, it is then necessary to study the impact of these treatments on the material behaviour, in particular for polymeric materials, even at relatively low disinfectant concentrations as used in potable water treatments. The objective of this work was to study the influence of sodium hypochlorite concentration on PERT/Al/PERT (PolyEthylene Raised Temperature) pipe degradation. Pipe samples were filled with chlorinated water solutions (concentrations ranging between 0 and 100 ppm) and maintained in static conditions during 270 days at 70 °C. The antioxidant depletion profile through a PERT wall was monitored using the oxidation induction time (OIT) method, which is a conventional technique of Differential Scanning Calorimetry. Chemical changes on the aged polymer were checked by Infrared Spectrometry. OIT change showed that the PERT stabilizing system was rapidly chemically consumed by the action of chlorinated water at 25 and 100 ppm concentrations. However, PERT degradation was strictly confined to the immediate inner wall. Only a 0.3 mm thick layer (inner part of the pipe) showed significant antioxidant depletion. An increase of the OH and C-O-C infrared bands was also observed on inner part of any samples during ageing which characterize the oxidation of the PERT on the inner wall. 相似文献
Abstract A highly selective and sensitive method is described for the determination of para- as well as ortho-isomers of aminophenol. The method involves oxidative coupling of aminophenol with Berthelot hypochlorite-alkaline phenol reagents. The reaction yielded a blue chromophose with p-aminophenol (∑=10,000 at 633 nm) and a dark green chromophore with o-aminophenol (∑=1436 at 845 nm). The reaction mechanisms involved in the chromophore formation are discussed. 相似文献