首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   1篇
化学   3篇
  2020年   1篇
  2014年   1篇
  2010年   1篇
排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
Fulvestrant (‘Faslodex’), an estrogen receptor antagonist, is available for the treatment of advanced breast cancer. The oil-based vehicle of Faslodex can lead to various adverse effects. A novel fulvestrant microcrystal (aqueous suspension) was developed in this study to eliminate these adverse effects. A sensitive and robust liquid chromatography tandem mass spectrometry method was developed and validated for the determination of fulvestrant in rat plasma using supported-liquid extraction. The separation of fulvestrant was achieved on an Agilent SB-C18 column (2.1 × 50 mm, 3.5 μm) with isocratic elution using fulvestrant-d3 as internal standard. Mass spectrometric detection was conducted in negative multiple reaction monitoring mode. Ion transitions were at m/z 605.5 → 427.5 for fulvestrant and m/z 608.5 → 430.5 for fulvestrant-d3. The excellent linearity was demonstrated over the range 0.05–100.0 ng/ml (r2 = 0.99). The lower limit of quantitation was 0.05 ng/ml, which was superior to that reported in literature The method validation was evaluated by selectivity, accuracy, precision, recovery and matrix effect in agreement with the US Food and Drug Administration guidance. The method was successfully applied to a pharmacokinetic study of a novel fulvestrant microcrystal in rats after intramuscular administration. It revealed that the rate of absorption increases and the extent of absorption is constant with a decrease in microcrystal diameter.  相似文献   
2.
Fulvestrant is used for the treatment of hormone receptor‐positive metastatic breast cancer in postmenopausal women with disease progression following anti‐estrogen therapy. Several reversed‐phase columns with variable silica materials, diameters, lengths, etc., were tested for the optimization study. A good chromatographic separation was achieved using a Waters X‐Terra RP18 column (250 × 4.6 mm i.d. × 5 µm) and a mobile phase, consisting of a mixture of acetonitrile–water (65:35; v/v) containing phosphoric acid (0.1%). The separation was carried out 40°C with detection at 215 nm.The calibration curves were linear over the concentration range between 1.0–300 and 1.0–200 µg/mL for standard solutions and biological media, respectively. The proposed method is accurate and reproducible. Forced degradation studies were also realized. This fully validated method allows the direct determination of fulvestrant in dosage form and biological samples. The average recovery of the added fulvestrant amount in the samples was between 98.22 and104.03%. The proposed method was also applied for the determination of fulvestrant from the polymeric‐based nanoparticle systems. No interference from using polymers and other excipients was observed in in vitro drug release studies. Therefore an incorporation efficiency of fulvestrant‐loaded nanoparticle could be determined accurately and specifically. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
3.
A rapid and sensitive high‐performance liquid chromatography and electrospray tandem mass spectrometry method was developed and validated for estimation of fulvestrant in rabbit plasma using liquid–liquid extraction. The separation and quantification of fulvestrant were achieved by reverse‐phase chromatography on a Sunfire C18 column (50 × 2.1. i.d., 3.5 μm) with isocratic elution at a flow rate of 300 μL/min using norethistrone as an internal standard from 500 μL plasma sample. The method was validated over the concentration range from 0.092 to 16.937 ng/mL with a lower limit of detection of 0.023 ng/mL. The intra‐day and inter‐day accuracy and precision were within 10%. The recovery was 85 and 90% for fulvestrant and norethistrone respectively. The chromatographic run time was only 2.5 min. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号