1.
Measurement of whole blood sirolimus and everolimus is required in order to optimize patient treatment following solid organ transplant. Assay by LC‐MS/MS is increasingly preferred; however efficient use of the instrument and short turnaround times are crucial. Use of a 1.6 µm solid‐core packing HPLC column (Cortecs) gave significant increases in efficiency, sensitivity and throughput compared with an existing method, following simple protein precipitation of small‐volume (20 μL) whole blood samples. Sirolimus, everolimus and the stable isotopic internal standard (13C2D4everolimus) eluted at around 0.8 min, and total analytical run time was 2.2 min, saving almost 4 min per sample compared with an existing method. Within‐assay imprecision (CV) was 3.3–8.5%, and between‐assay imprecision was 2.2–10.8%. Retrospective assay of external quality assurance samples and comparison of patient samples assayed in parallel showed only small differences (between +6.8 and ?1.9%) in results using the Cortecs column when compared with the existing method. No significant interferences or ion suppression were observed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
2.
Tacrolimus (TAC, FK‐506) and everolimus (EVE, RAD001) are immunosuppressors used to treat pediatric patients undergoing liver transplantation. Their hematic TDM by liquid chromatography became standard practice. However, it does not always reflect concentrations at their active site. Our aim was to develop and validate a new method for the simultaneous TAC and EVE quantification into target cells: peripheral blood mononuclear cells (PBMCs). Peripheral blood mononuclear cells were collected using cell preparation tubes; cells number and mean cell volume were evaluated by an automatic cell counter. TAC and EVE were quantified using UHPLC–MS/MS coupled with an automated online solid‐phase extraction platform. Chromatographic run was performed on an Acquity UPLC® BEH C18 1.7 μm (2.1 × 50 mm) column at 45 °C, for 6 min at 0.5 ml/min. Mobile phases were water and methanol, both with 2 mm ammonium acetate and 1 ml/l formic acid). XBridge® C8 10 μm (1 × 10 mm) SPE cartridges were used, and the internal standard was ascomycin. Following Food and Drug Administration guidelines, method validation resulted in high sensitivity and specificity. Calibration curves were linear (r 2 = 0.998) and intra‐day and inter‐day imprecision and inaccuracy were <15%. A reproducible matrix effect was observed, with a good recovery for all compounds. Drug amounts in 15 ‘real’ PBMCs samples from five pediatric patients in co‐treatment resulted within the calibration range (0.039–5 ng). Concentrations from each patient were standardized using their evaluated mean cell volume: intra‐PBMCs concentration was meanly 19.23 and 218.61 times higher than the hematic one for TAC and EVE, respectively. This method might be useful in clinical routine, giving reliable data on drugs concentration at the active site. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号