首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   161篇
  免费   15篇
  国内免费   4篇
化学   157篇
力学   4篇
物理学   19篇
  2023年   14篇
  2022年   26篇
  2021年   4篇
  2020年   8篇
  2019年   13篇
  2018年   7篇
  2017年   9篇
  2016年   3篇
  2015年   7篇
  2014年   7篇
  2013年   4篇
  2012年   9篇
  2011年   20篇
  2010年   7篇
  2009年   8篇
  2008年   3篇
  2007年   8篇
  2006年   11篇
  2005年   9篇
  2004年   1篇
  2003年   1篇
  1993年   1篇
排序方式: 共有180条查询结果,搜索用时 15 毫秒
1.
Technical advances in the development of field-deployable capillary and microchip electrophoretic instruments and reports of their deployment between 2013 and 2017 were reviewed. Strategies and considerations in the design of the injection, separation and detection hardware, chemistry and associated infrastructure were discussed from an in-field perspective, with portability, robustness and automation/“ease of use” featuring as key requirements. Integration of functionality is important for adequate in-field performance. Progress was made towards the use of multiple channel devices for increased throughput and/or resolving power, mixing devices for on-line/in-line sample derivatization, battery operation and temperature control. The strengths and weaknesses of the various approaches described in the literature are discussed from the perspective of in-field operation. An overview of the applications of the field electrophoretic instruments is provided, including environmental science and planetary investigation.  相似文献   
2.
Law WS  Kubán P  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2005,26(24):4648-4655
The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.  相似文献   
3.
An extension of a capillary electrophoresis instrument coupled to a sequential injection analysis manifold was developed for automated measurements with on-line solid-phase extraction preconcentration. An in-house built capacitively coupled contactless conductivity detector was employed for sensitive detection with narrow capillaries of 25 μm internal diameter. The system was assembled into standardized 19 in. frames and racks for easy transport and mobile deployment. The system can be left running unattendedly without manual intervention with good operation stability. To demonstrate the application of the system, a method for the determination of four drugs, namely ibuprofen, diclofenac, naproxen and bezafibrate, was developed with enrichment factors of up to several hundreds. Detection of the drug residues down to the nM-scale was found possible and the method was found suitable for the detection of ibuprofen in the waste water of a hospital in Hanoi.  相似文献   
4.
Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre‐ or postcolumn oxidation for fluorescence detection (HPLC‐FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on‐site monitoring. In this study, CE methods were developed for C4D, FLD, UV absorption detection, and MS—making this first report of C4D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE‐UV and CZE‐C4D methods provide better resolution, selectivity, and separation efficiency compared to CZE‐MS and MEKC‐FLD. The sensitivity of the CZE‐C4D and MEKC‐FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE‐C4D and 60.9 to 104 ng/mL for MEKC‐FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE‐C4D and MEKC‐FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE‐C4D method suffered from significant interferences from the shellfish matrix, MEKC‐FLD was successfully used for PST screening of a periodate‐oxidized mussel sample, with results confirmed by HPLC‐FLD. This confirms the potential of MEKC‐FLD for screening of PSTs in shellfish samples.  相似文献   
5.
Dielectrophoresis (DEP) is an AC electrokinetic effect mainly used to manipulate cells. Smaller particles, like virions, antibodies, enzymes, and even dye molecules can be immobilized by DEP as well. In principle, it was shown that enzymes are active after immobilization by DEP, but no quantification of the retained activity was reported so far. In this study, the activity of the enzyme horseradish peroxidase (HRP) is quantified after immobilization by DEP. For this, HRP is immobilized on regular arrays of titanium nitride ring electrodes of 500 nm diameter and 20 nm widths. The activity of HRP on the electrode chip is measured with a limit of detection of 60 fg HRP by observing the enzymatic turnover of Amplex Red and H2O2 to fluorescent resorufin by fluorescence microscopy. The initial activity of the permanently immobilized HRP equals up to 45% of the activity that can be expected for an ideal monolayer of HRP molecules on all electrodes of the array. Localization of the immobilizate on the electrodes is accomplished by staining with the fluorescent product of the enzyme reaction. The high residual activity of enzymes after AC field induced immobilization shows the method's suitability for biosensing and research applications.  相似文献   
6.
Determination of the broad-spectrum antibiotics amoxicilline (AMX) and ceftazidime (CTZ) in blood serum and microdialysates of the subcutaneous tissue of the lower limbs is performed using CE with contactless conductivity detection (C4D). Baseline separation of AMX is achieved in 0.5 M acetic acid as the background electrolyte and separation of CTZ in 3.2 M acetic acid with addition of 13% v/v methanol. The CE-C4D determination is performed in a 25 µm capillary with suppression of the EOF using INST-coating on an effective length of 18 cm and the attained migration time is 4.2 min for AMX and 4.4 min for CTZ. The analysis was performed using 20 µl of serum and 15 µl of microdialysate, treated by the addition of acetonitrile in a ratio of 1/3 v/v and the sample is injected into the capillary using the large volume sample stacking technique. The LOQ attained in the microdialysate is 148 ng/ml for AMX and 339 ng/ml for CTZ, and in serum 143 ng/ml for AMX and 318 ng/ml for CTZ. The CE-C4D method is employed for monitoring the passage of AMX and CTZ from the blood circulatory system into the subcutaneous tissue at the sites of diabetic ulceration in patients suffering from diabetic foot syndrome and also for measuring the pharmacokinetics following intravenous application of bolus antibiotic doses.  相似文献   
7.
Cancer is a highly heterogenous disease that requires precise detection tools and active surveillance methods. Liquid biopsy assays provide an agnostic way to follow the complex trajectory of cancer, providing better patient stratification tools for optimized treatment. Here, we present the development of a low-volume liquid biopsy assay called cyc-DEP (cyclic immunofluorescent imaging on dielectrophoretic chip) to profile biomarkers collected on a dielectrophoretic microfluidic chip platform. To enable on-chip cyclic imaging, we optimized a fluorophore quenching method and sequential rounds of on-chip staining with fluorescently conjugated primary antibodies. cyc-DEP allows for the quantification of a multiplex array of proteins using 25 µl of a patient plasma sample. We utilized nanoparticles from a prostate adenocarcinoma (LNCaP) cell line and a panel of six target proteins to develop our proof-of-concept technique. We then used cyc-DEP to quantify blood plasma levels of target proteins from healthy individuals, low-grade and high-grade prostate cancer patients (n = 3 each) in order to demonstrate that our platform is suitable for liquid biopsy analysis in its present form. To ensure accurate quantification of signal intensities and comparisons between different samples, we incorporated a signal intensity normalization method (fluorescent beads) and a custom signal intensity quantification algorithm that account for the distribution of signal across hundreds of collection regions on each chip. Our technique enabled a threefold improvement in multiplicity for detecting proteins associated with fluid samples, opening doors for early detection, and active surveillance through quantification of a multiplex array of biomarkers from low-volume liquid biopsies.  相似文献   
8.
Bottom‐up assembly by dielectrophoresis (DEP) has emerged in recent years as a viable alternative to conventional top–down fabrication of electronic devices from nanomaterials, particularly carbon nanotubes and graphene. Here, we demonstrate how this technique can be extended to fabricate devices containing carbon nanotubes and graphene suspended between two electrodes over a back‐gate electrode. The suspended device geometry is critical for the development of nano‐electromechanical devices and to extract maximum performance out of electronic and optoelectronic devices. This technique allows for parallel assembly of devices over large scale. (© 2015 WILEY‐VCH Verlag GmbH &Co. KGaA, Weinheim)  相似文献   
9.
陈湖水  江建坤  易佳  谢天尧 《色谱》2020,38(6):708-714
采用场放大进样(FASI)-毛细管电泳非接触式电导检测法(CE-C4D),结合液液萃取(LLE)的样品净化预处理技术,分离检测了酱油中人工合成甜味剂安赛蜜。酱油样品经酸化后,用乙酸乙酯作为萃取剂,成功地消除了酱油中含有的大量无机盐等复杂基体对微量安赛蜜的干扰。实验对影响LLE萃取效率和FASI-CE-C4D分离检测的关键因素进行了讨论,特别是对样品净化前处理过程中萃取剂及用量、样品酸化pH值、萃取时间、萃取温度等条件进行了优化。结果表明,酱油中的安赛蜜可获得良好分离和灵敏检测,检出限和定量限分别为0.15 mg/kg和0.48 mg/kg。对市售酱油样品进行安赛蜜的加标回收测定,得到加标回收率为92.3%~108.1%,相对标准偏差<8.0%。该法具有简单快速、灵敏高效、分析成本低的优点,能满足酱油中安赛蜜的分析检测要求。  相似文献   
10.
综述了毛细管电泳(CE)及芯片毛细管电泳(MCE)的电容耦合非接触电导检测(Capacitively Coupled Contactless Conductivity detection,C4D)的研究状况;并分别对其装置、检测的影响因素及其应用进行了评述。引用文献81篇。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号