排序方式: 共有32条查询结果,搜索用时 16 毫秒
1.
HL—1装置等离子体密度反馈实验 总被引:1,自引:1,他引:0
本文叙述HL-1装置用反馈脉冲补充送气方式控制等离子体密度的方法及实验结果。给出了在固有的物理实验条件下的最佳反馈方式,实现了对密度的有效控制及反馈。讨论了在不同密度条件下的几种反馈方式及反馈系统尚存在的不足之处。 相似文献
2.
Summary The performance of injection valves with both curtain- and single-flow column couplings has been evaluated using reverse-phase octadecylsilane columns and a standard test mixture. The results are compared with those obtained from septum and stopped-flow syringe injections.Stopped-flow valve injection has been examined similarly. Configurations and couplings which give optimum efficiency and reproducibility are recommended. 相似文献
3.
4.
Electropolishing of Ti was carried out in alcohol-based electrolyte and subsequently the polished Ti was anodized in ethylene glycol containing 0.25 wt% NH4F. Anodization of polished and non-polished Ti, respectively, showed no big difference in the degree of local arrangement of the nanotubes, whereas the surface roughness on a large area was dramatically improved in the anodized polished Ti. Anodization of polished Ti leads to the formation of nanotubular TiO2 structures with more uniform length and relatively time-independent density of nanotubes compared to that prepared with anodization of non-polished Ti, meaning that electropolishing is indispensable for the formation of uniform nanotubular TiO2 structures. 相似文献
5.
Summary An on-line two-dimensional open tubular column supercritical fluid chromatograph was constructed and evaluated. A rotary valve interface allowed independent flow control of two 50-m i.d. open tubular columns, providing maximum versatility for heartcutting. A solvent-venting injection technique was incorporated in the system that enabled single or multiple 2.0-L volumes to be injected into an uncoated, yet deactivated, length of capillary precolumn without flooding of the analytical column. A cold trap was employed to refocussolutes from single or multiple fractional cuts after being transferred to the second dimension. The performance of the system was demonstrated with the analysis of mixtures of polycyclic aromatic compounds and steroids. Efficiencies of 4,500 plates m–1 were preserved in the second column after heartcutting. 相似文献
6.
光伏发电系统充放电控制策略研究 总被引:1,自引:0,他引:1
本对光伏发电系统中影响蓄电池寿命各因素进行了简单分析,并在此基础上提出了一种新的充放电控制策略。实验结果证明该控制策略能较显提高蓄电池的放电容量。 相似文献
7.
控制阀在工业控制领域扮演十分重要的角色,但目前国内对控制阀性能测试评估系统的研究十分薄弱,常规的仪器仪表很难精确测试控制阀的性能。本文基于NI compactRIO硬件、各类传感器以及Labview软件开发设计了一套控制阀性能测试评估系统,该系统实现了控制阀的在线测试和功能评估,并且可将控制阀各项性能指标评估结果汇集于一张类似体检单的报表显示。采用该系统对某公司的直通气开式薄膜调节阀S9044进行了性能测试评估,实验结果表明,该系统能够精确地测试出调节阀的各项性能指标,且系统软件交互界面良好、扩展性强、精度高。 相似文献
8.
U. R. Tjaden H. Lingeman H. J. E. M. Reeuwijk E. A. de Bruijn H. J. Keizer J. van der Greef 《Chromatographia》1988,25(9):806-810
Summary Fluorouracil has been analyzed with a reversed-phase ion-pair liquid chromatographic system applying PRP-1 as the stationary phase. A valve switching technique was applied for the separation of the analyte and some other chemotherapeutic agents. The described procedure gives a rapid screening for the analyte in urine and plasma samples without interferences from late eluting solutes. Biological samples are pretreated by means of a liquid-liquid extraction resulting in a recovery of about 52% for plasma and urine with minimum detectable amounts of about 5ng/ml. The sensitivity and the selectivity of the procedure allows the monitoring of fluorouracil in body fluids and subsequent pharmaco-kinetic studies of the fluoropyrimidine. 相似文献
9.
Transient behavior of a centrifugal pump during starting period 总被引:1,自引:0,他引:1
A theoretical analysis on transient flow inside a centrifugal pump was carried out, building on unsteady and incompressible fluid equations applied to the impeller during the starting periods. The transient flow behavior is governed by two hyperbolic partial differential equations; namely continuity and motion equations. The characteristics method of the specified time intervals was used to analyze the dynamic characteristic of the pump. To follow the dynamic behavior of the pump during startup periods, a numerical study was performed on the pump impeller with different openings of the discharge valve. The comparison between the numerical and experimental results of the pump characteristic curve has shown a good concordance. The results have also revealed that the pressure increase is important in the case of a short starting period of the pump and a large mass of water in the pipelines. In this study, the effect of the impeller diameter and number of blades on the pressure evolution was also analyzed. 相似文献
10.