首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   4篇
  2020年   1篇
  2019年   1篇
  2013年   2篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Riociguat is novel antihypertensive drug for treatment of pulmonary hypertension. As such, it is still being tested in many clinical and pharmacokinetic trials. Existing methods that determine serum riociguat and desmethylriociguat (DMR) are based solely on liquid chromatography with mass spectrometry. Therefore, we present a novel capillary electrophoresis with mass spectrometry method (CE-MS) for their determination in human serum as alternative method for ongoing trials. Complete resolution of both analytes was achieved by means of pH optimization of ammonium formate background electrolytes that are fully compatible with ESI/MS detection. Simple liquid-liquid extraction was used as sample pretreatment. The calibration dependence of the method was linear (in the range of 10–1000 ng/mL), with adequate accuracy (90.1–114.9%) and precision (13.4%). LOD and LOQ were arbitrarily set at 10 ng/mL for both analytes. Clinical applicability was validated using serum samples from patients treated with riociguat in pharmacokinetic study and the results corresponded with reference HPLC-MS/MS values. Capillary electrophoresis proved to be sensitive and selective tool for the analysis of riociguat and DMR.  相似文献   
2.
3.
Riociguat is a novel antihypertensive drug for the treatment of pulmonary hypertension. We present electrophoretic characterization, i.e. migration behavior of riociguat and metabolite M1 as support for optimized CZE/MS assay. Fundamental separation parameters, such as peak width, symmetry, and resolution are studied in a series of ammonium formate buffers within pH range 2.60–5.61. The narrow region of peak symmetry lies close to pH 4.0 for both analytes. Accordingly, the value of resolution maximizes in a background electrolyte adjusted to pH 4.10. Basic calibration parameters estimated from CZE experiments with absorption photometric and mass spectrometric detection of riociguat and metabolite M1 were evaluated. More than three orders lower LOD was achieved with high resolution mass spectrometric detection. The observed difference in the sensitivity of both detection techniques gives priority to the utilization of CZE/MS in practice. The values of dissociation constants of riociguat and metabolite M1, pKBH, were determined from CZE measurements in lithium formate and lithium acetate background electrolytes with constant ionic strength. The value of pKBH = 4.30 ± 0.02 for riociguat corresponds well to the value already presented in the literature. According to our observation, metabolite M1 behaves like a slightly stronger base with estimated pKBH = 4.40 ± 0.02.  相似文献   
4.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号