首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   44篇
  免费   0篇
化学   33篇
力学   5篇
数学   3篇
物理学   3篇
  2023年   2篇
  2022年   3篇
  2021年   1篇
  2019年   2篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2014年   3篇
  2013年   7篇
  2012年   2篇
  2011年   3篇
  2009年   2篇
  2008年   1篇
  2007年   2篇
  2006年   3篇
  2004年   4篇
  2003年   1篇
  2002年   3篇
  1997年   1篇
  1994年   1篇
排序方式: 共有44条查询结果,搜索用时 15 毫秒
1.
 The complexity of different quality standards can, in principle, be covered by different approaches and strategies. In-depth process mapping of quality control (QC) work streams was used by the analytical laboratories of Lonza AG to show up the principle differences in being compliant to different quality systems. The results identified two main drivers for all necessary actions: process-related activities and infrastructure-related activities. In addition, a clear indication of the economic impact of these driving forces was gained, which led the laboratories to decide on a process-oriented approach. This approach has the advantage of being able to reflect the different demands of different quality assurance (QA) regulations within the same QC organizational structure. Following the process helps avoid unnecessary efforts in analytical work and represents a very economical approach, at the same time, providing high flexibility to react to different QA or customer demands. Received: 5 July 2002 Accepted: 12 November 2002 Acknowledgements The process-oriented approach resulted from many, very challenging discussions for which I would like to thank the staff of my organization (Analytics & QC), especially, the QA staff and the LIMS team. Presented at Analytica Conference, 23–26 April 2002, Munich, Germany Correspondence to B. Ciommer  相似文献   
2.
In this paper, the three-dimensional (3D) interfacial fracture is analyzed in a one-dimensional (1D) hexagonal quasicrystal (QC) coating structure under mechanical loading. A planar interface crack with arbitrary shape is studied by a displacement discontinuity method. Fundamental solutions of interfacial concentrated displacement discontinuities are obtained by the Hankel transform technique, and the corresponding boundary integral-differential equations are constructed with the superposition principle. Green’s functions of constant interfacial displacement discontinuities within a rectangular element are derived, and a boundary element method is proposed for numerical simulation. The singularity of stresses near the crack front is investigated, and the stress intensity factors (SIFs) as well as energy release rates (ERRs) are determined. Finally, relevant influencing factors on the fracture behavior are discussed.  相似文献   
3.
Resveratrol is a polyphenol that has numerous interesting biological properties, but, per os, it is quickly metabolized. Some of its metabolites are more concentrated than resveratrol, may have greater biological activities, and may act as a kind of store for resveratrol. Thus, to understand the biological impact of resveratrol on a physiological system, it is crucial to simultaneously analyze resveratrol and its metabolites in plasma. This study presents an analytical method based on UHPLC-Q-TOF mass spectrometry for the quantification of resveratrol and of its most common hydrophilic metabolites. The use of 13C- and D-labeled standards specific to each molecule led to a linear calibration curve on a larger concentration range than described previously. The use of high resolution mass spectrometry in the full scan mode enabled simultaneous identification and quantification of some hydrophilic metabolites not previously described in mice. In addition, UHPLC separation, allowing run times lower than 10 min, can be used in studies that requiring analysis of many samples.  相似文献   
4.
An automated system for the monitoring of volatile organic compound (VOC) ozone precursors in ambient air is described. The measuring technique consists of subambient preconcentration on a cooled trap followed by thermal desorption and GC/FID analysis. First, the technical development, which permits detection limits below 0.05 ppbv to be reached, proceeded in two steps: (1) the determination of optimum sampling parameters (trap composition and conditioning, outlet split, desorption temperature); (2) the development of a reliable calibration method based on a highly accurate standard. Then, a 4-year field application of the hourly measuring chain was carried out at two urban sites. On the one hand, quality control procedures provided the best VOC identification (peak assignment) and quantification (reproducibility, blank system control). On the other hand, the success and performances of the routine experience (88% of the measurements covered more than 40 target compounds) indicated the high quality and suitability of the instrumentation which is actually applied in several French air quality monitoring networks. Finally, an example of data analysis is presented. Data handling identified important organic compound sources other than vehicle exhaust.  相似文献   
5.
An efficient blood plasma clean-up method was developed, where methanol protein precipitation was applied, followed by zirconium silicate assisted exclusion of residual proteins. A strong binding of zirconium (IV) silicate to the proteins enabled the elimination of remaining proteins after solvent deproteinization through a rapid solid-phase extraction (SPE) procedure. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF MS) was used for monitoring the proteins during clean-up practice applied to human plasma samples. The proteins were quantified by colorimetric detection using the bicinchoninic acid (BCA) assay. The presented analytical strategy resulted in the depletion of >99.6% proteins from human plasma samples. Furthermore, high-performance liquid chromatography hyphenated to diode-array and electrospray ionization mass spectrometric detection (HPLC–DAD/ESI MS) was applied for qualitative and quantitative analysis of the caffeoylquinic acids (CQAs) and their metabolites in human plasma. The procedure demonstrated high recoveries for the standard compounds spiked at different concentrations. Cynarin and chlorogenic acid were recovered in the range of 81–86% and 78–83%, respectively. Caffeic acid was extracted in the excess of 89–92%, while ferulic acid and dihydroxyhydrocinnamic acid showed a recovery of 87–91% and 92–95%, respectively. The method was partially validated in accordance with FDA-Industry Guidelines for Bioanalytical Method Validation (2001). The presented scheme improves the clean-up efficacy of the methanol deproteinization, significantly reduces the matrix effects and provides a great analytical tool for the isolation of small molecules from human plasma.  相似文献   
6.
Analytical methods for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are widely available and are the result of a vast amount of environmental analytical method development and research on persistent organic pollutants (POPs) over the past 30–40 years. This review summarizes procedures and examines new approaches for extraction, isolation, identification and quantification of individual congeners/isomers of the PCBs and OCPs. Critical to the successful application of this methodology is the collection, preparation, and storage of samples, as well as specific quality control and reporting criteria, and therefore these are also discussed. With the signing of the Stockholm convention on POPs and the development of global monitoring programs, there is an increased need for laboratories in developing countries to determine PCBs and OCPs. Thus, while this review attempts to summarize the current best practices for analysis of PCBs and OCPs, a major focus is the need for low-cost methods that can be easily implemented in developing countries. A “performance based” process is described whereby individual laboratories can adapt methods best suited to their situations. Access to modern capillary gas chromatography (GC) equipment with either electron capture or low-resolution mass spectrometry (MS) detection to separate and quantify OCP/PCBs is essential. However, screening of samples, especially in areas of known use of OCPs or PCBs, could be accomplished with bioanalytical methods such as specific commercially available enzyme-linked immunoabsorbent assays and thus this topic is also reviewed. New analytical techniques such two-dimensional GC (2D-GC) and “fast GC” using GC–ECD may be well-suited for broader use in routine PCB/OCP analysis in the near future given their relatively low costs and ability to provide high-resolution separations of PCB/OCPs. Procedures with low environmental impact (SPME, microscale, low solvent use, etc.) are increasingly being used and may be particularly suited to developing countries. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   
7.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   
8.
NAD(P)H:quinone oxidoreductase 1 (NQO1, DT-diaphorase) is a prognostic biomarker and a potential therapeutic target for various tumors. Therefore, it is of significance to develop a robust method for the absolute quantification of NQO1. This study aimed to develop and validate a LC–MS/MS based method and to test the appropriateness of using non-isotopic analog peptide as the internal standard (IS) by comparing with a stable isotope labeled (SIL) peptide. The chromatographic performance and mass spectra between the selected signature peptide of NQO1 and the non-isotopic peptide were observed to be very similar. The use of the two internal standards was validated appropriate for the absolute quantification of NQO1, as evidenced by satisfactory validation results over a concentration range of 1.62–162 fmol μL−1. This method has been successfully applied to the absolute quantification of NQO1 expression in various tumor cell lines and tissues. NQO1 expression in human tumor tissues is much higher than that in the neighboring normal tissues in both the cases of lung and colon cancer. The quantitative results obtained from the isotopic and non-isotopic methods are quite similar, further supporting that the use of non-isotopic analog peptide as internal standard is appropriate and feasible for the quantification of NQO1. By comparing with a classical isotopic IS, the present study indicates that the use of a non-isotopic peptide analog to the proteotypic peptide as the internal standard can get equal accuracy and preciseness in measuring NQO1. The universal applicability of the non-isotopic IS approach for the quantification of proteins warrants further research.  相似文献   
9.
LC-MS/MS has been widely applied to the quantitative analysis of tissue samples. However, one key remaining issue is that the extraction recovery of analyte from spiked tissue calibration standard and quality control samples (QCs) may not accurately represent the “true” recovery of analyte from incurred tissue samples. This may affect the accuracy of LC-MS/MS tissue bioanalysis. Here, we investigated whether the recovery determined using tissue QCs by LC-MS/MS can accurately represent the “true” recovery from incurred tissue samples using two model compounds: BMS-986104, a S1P1 receptor modulator drug candidate, and its phosphate metabolite, BMS-986104-P. We first developed a novel acid and surfactant assisted protein precipitation method for the extraction of BMS-986104 and BMS-986104-P from rat tissues, and determined their recoveries using tissue QCs by LC-MS/MS. We then used radioactive incurred samples from rats dosed with 3H-labeled BMS-986104 to determine the absolute total radioactivity recovery in six different tissues. The recoveries determined using tissue QCs and incurred samples matched with each other very well. The results demonstrated that, in this assay, tissue QCs accurately represented the incurred tissue samples to determine the “true” recovery, and LC-MS/MS assay was accurate for tissue bioanalysis. Another aspect we investigated is how the tissue QCs should be prepared to better represent the incurred tissue samples. We compared two different QC preparation methods (analyte spiked in tissue homogenates or in intact tissues) and demonstrated that the two methods had no significant difference when a good sample preparation was in place. The developed assay showed excellent accuracy and precision, and was successfully applied to the quantitative determination of BMS-986104 and BMS-986104-P in tissues in a rat toxicology study.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号