Pressurized liquid extractions were performed on eight sediments in order to investigate if a modified US EPA method (100 °C, 100 bar, n-heptane/acetone (1:1), 2 × 5 min) provided exhaustive extractions of polychlorinated biphenyls (PCBs) from sediment, and to study if the extractability of PCBs from the different sediments was affected by characteristics of the sediment. The recovery from the eight native sediments, contaminated in nature, was between 96.4% and 98.9%, as an average of the recoveries from 10 PCB congeners. Hundred percent recovery was defined as the sum of two consecutive extractions (2 × 5 min each) at the stated conditions. The recoveries of the individual congeners were above 94%, except for one congener in one sediment, which had a recovery of 92%. When the recoveries and different characteristics of the sediments were compared, no correlation appeared between recoveries and sediment PCB concentration, total organic carbon (TOC), soot carbon (SC) or amorphous carbon (AC). The fact that carbon did not influence the extractions was somewhat surprising, since previous experiments have indicated a connection. Instead, statistically significant (p < 0.05) correlations were observed for water content and carbon/nitrogen (C/N) ratio. The decrease in recoveries with decreased water content was attributed to less access of the solvent to the analytes due to less matrix swelling. The lowered recoveries with increased C/N ratio can indicate that a difference in structure of the organic matter exists, which influences the binding strength between the analytes and the matrix. The difference in structure can possibly be explained by different origin of the organic matter or by aging effects. Overall the method was found to be exhaustive and the excellent recoveries show that sediment characteristics do not influence the extractions markedly. 相似文献
Ultrasonic waves in a liquid induce the formation of cavitation bubbles. Submitted to an oscillating pressure field, cavities filled with vapor and dissolved gas pulsate, grow and implode violently when they reach a critical resonant size. According to the 慼ot spot?theory, extremely high temperature and pressure are produced during the collapse of cavitation bubbles1. Under these extreme conditions, the molecules vaporized in the bubbles as well as in the surrounding condensed layer could … 相似文献
Polychlorinated biphenyls (PCBs) and chlorobenzenes (CBzs) are two classes of dioxin precursors formed in municipal solid waste incinerators (MSWIs); they produce negative health effects similar to those of dioxins. Reducing the analytical time required for determining the concentrations of these compounds in MSWIs is important for quickly evaluating their importance and assessing associated health risks. In the present study, water is used as a safe and environmentally friendly solvent in microwave-assisted extraction (MAE) for PCB and CBz analyses. MAE is compared with traditional Soxhlet extraction (SE) to determine the extraction efficiencies. The evaluation of extraction efficiencies shows that MAE has a high extraction efficiency compared with that of SE when water content is lower than 60%. Furthermore, the extraction time and organic solvent consumption are reduced with MAE compared with SE. 相似文献
The reliability of the two-layer own N-layered integrated molecular orbital and molecular mechanics (ONIOM) method was examined for the SN2 reaction CH(4–n)Cln+OH–. In the ONIOM calculation, only the methyl chloride and OH–were treated at a high level and the effect of polychlorination was taken into account only at a low level. The ONIOM results were compared with the target CCSD(T)/aug-cc-pVDZ//MP2/aug-cc-pVDZ results obtained by Borisov etal. [(2001) J. Phys. Chem. A 105:7724]. The ONIOM[MP2/aug-cc-pVDZ:B3LYP/6-31+G(d)] was found to reproduce well the target geometry and energy at the MP2/aug-cc-pVDZ level. The single-point improved energetics at the ONIOM[CCSD(T)/aug-cc-pVDZ:MP2/6-31+G(d)] is found to give results nearly as accurate as the target CCSD(T)/aug-cc-pVDZ//MP2/aug-cc-pVDZ results. The substantially reduced cost, 20% for optimization and 5% for single-point improved energy of the target cost for n=4, as well as small errors suggest that ONIOM is a powerful tool for accurate potential-energy surfaces of the reaction of large polyhalohydrocarbons. 相似文献
Chemical investigation of the dichloromethane extract of the Red Sea marine sponge Lamellodysidea herbacea led to the isolation of seven new polychlorinated derivatives 3-6 and 8-10 in addition to the known dysidamide 1, dysidamide B 2 and dysidamide C 7. Their structures were established by extensive NMR spectroscopic data. The absolute configuration of compound 9 was determined by X-ray crystallographic diffraction analysis. Dysidamide 1 exhibited neurotoxic effects towards both mesencephalic and cortical murine neurones at 0.8 μg/ml. 相似文献
Chromatography has been an important tool in marine laboratories. Since the 1960s, marine laboratories have been involved in the analysis of polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs), and brominated flame retardants (BFRs). Column chromatography and liquid chromatography (LC) techniques have been used, mainly in the clean-up phase, while gas chromatography (GC) has been used extensively in the final determination of these contaminants. Developments have been observed from the use of packed GC columns, via capillary columns to the use of heart-cut multi-dimensional GC and comprehensive multi-dimensional GC. The progress made in interlaboratory studies and the availability of certified reference materials are discussed. 相似文献
On-line coupled supercritical fluid extraction and gas chromatography (SFE-GC) has been utilized for the determination of PCBs and other organochlorine compounds in human milk and blood serum. The procedure involved preconcentration of the sample on C18-silica sorbent in an extraction cell: after precipitation of the proteins up to 20 ml of human milk was concentrated on 0.5 g of sorbent. Serum (up to 5 ml) was applied to the C18 material without pretreatment. Basic alumina was utilized as a selective adsorbent for lipids in the on-line SFE-GC system. The method was used to analyze milk and serum spiked with 0.5 and 10 ng of Aroclor 1260 and the results compared with those obtained by liquid–liquid extraction of serum. 相似文献
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.
An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ1=μ2=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. 相似文献
A new additive scheme is proposed for the precalculation of gas chromatographic retention indices of complex organic compounds. The principal feature of this approach is the absence of previously calculated I increments for any structural fragments or functional groups in the molecule. Instead, arithmetical operations involving I values of simpler structural analogues of target compounds are used directly. I precalculation for polychlorinated hydroxybiphenyls (839 congeners) on the HP-5 stationary phase was chosen as one of the most important applications of the method under discussion. Such a large number of congeners cannot be obtained as reference samples and their gas chromatographic (GC)-mass spectrometric (MS) identification should therefore be based currently on precalculated I values. 相似文献
The 1H and 13C NMR chemical shifts for six toxaphene congeners: 2-exo,3-endo,6-exo,8,9,10-hexachloro- (1), 2-exo,3-endo,5-exo,9,9,10,10-heptachloro- (2), 2-exo,3-endo,6-exo,8,9,10,10-heptachloro- (3), 2-exo,3-endo,5-exo,6-endo,8,9,10-heptachloro- (4), 2-exo,3-endo,5-exo,6-endo,8,9,9,10-octachlorobornane (5) and 2,5-endo,6-exo,8,9,9,10,10-octachloro-2-bornene (6) are reported. Their chemical shift assignments have been obtained by means of Pulsed Field Gradient (PFG) Double Quantum Filtered (DQF) 1H,1H correlation spectroscopy (COSY), PFG 1H,13C Heteronuclear Multiple Quantum Coherence (HMQC) and PFG 1H,13C Heteronuclear Multiple Bond Correlation (HMBC) experiments. A single crystal X-ray structural analysis was made for compounds 1, 3, 4 and 6. The prevalences of two octachlorobornene rotamers (6a,6b) were elucidated by ab initio MO method and single point DFT/GIAO calculations for 13C chemical shifts. Theoretical calculations proved that the single crystal structure of 6 corresponds its most stable conformer in solution. 相似文献