首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   0篇
化学   31篇
物理学   1篇
  2021年   1篇
  2017年   2篇
  2016年   1篇
  2015年   1篇
  2013年   2篇
  2012年   7篇
  2011年   3篇
  2010年   2篇
  2009年   1篇
  2008年   3篇
  2007年   4篇
  2006年   1篇
  2005年   1篇
  2003年   2篇
  1987年   1篇
排序方式: 共有32条查询结果,搜索用时 328 毫秒
1.
The high sensitivity that can be attained using an enzymatic system and mediated by 4-tert-butylcatechol (4-TBC) has been verified by on-line interfacing of a rotating biosensor and continuous flow/stopped-flow/continuous-flow processing. Horseradish peroxidase, HRP, [EC 1.11.1.7], immobilized on a rotating disk, in presence of hydrogen peroxide catalyzed the oxidation of 4-TBC, whose back electrochemical reduction was detected on glassy carbon electrode surface at −150 mV. Thus, when penicillamine (PA) was added to the solution, these thiol-containing compounds participate in Michael type addition reactions with 4-TBC to form the corresponding thioquinone derivatives, decreasing the peak current obtained proportionally to the increase of its concentration. The highest response for PA was obtained around pH 7. This method could be used to determine PA concentration in the range 0.02-80 μM (r = 0.998). The determination of PA was possible with a limit of detection of 7 nM, in the processing of as many as 50 samples per hour. The HRP-rotating biosensor was successfully applied to the determination of PA in pharmaceutical formulations.  相似文献   
2.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   
3.
A simple, robust and sensitive sequential injection spectrophotometric method for the assay of penicillamine (PA) in pharmaceutical formulations is developed. The method was based on the complex formation when PA is reacted with iron(III) solution in hydrochloric acid media. The deep blue colored PA-iron(III) complex produced is monitored at a maximum wavelength of 600 nm. A five level orthogonal array design coupled to genetic algorithm was employed to obtain the optimum experimental conditions for the determination of PA using peak absorbance as the measure of the system's performance criterion. A linear dynamic range for the determination of PA of 25-300 ppm was obtained with a sampling frequency of 50 h−1 and a relative standard deviation of less than 0.98%. The method was successfully applied to the determination of PA in pharmaceutical formulations.  相似文献   
4.
The functionalized multi‐wall carbon nanotube with 1,2‐naphthoquinone‐4‐sulfonic acid sodium (Nq‐MWNT) was fabricated by a simple and low‐cost method. Techniques of scanning electron microscope (SEM) with energy dispersive X‐ray (EDX) analysis, fourier transform infrared spectroscopy (FT‐IR), ultraviolet visible spectroscopy (UV‐vis) and cyclic voltammetry (CV) were used to characterize the property of the Nq‐MWNT. The results showed that the MWNT with high functionalization of Nq can be obtained using this simple method. The Nq‐MWNT modified carbon paste electrode (Nq‐MWNT/CPE) was fabricated by drop‐casting technique. The resulted modified electrode was tested successfully to detection D‐penicillamine (D‐PA) and captopril (CAP) in an aqueous solution. It is found that D‐PA and CAP participate in Michael addition reaction with Nq on MWNT to form the corresponding thioquinone derivative. The reoxidation of adducts at a potential of less positive than D‐PA and CAP at the surface of the bare CPE leads to an increase in the oxidative current, which is proportional to the concentration of D‐PA and CAP. The catalytic response showed a wide linear range (3‐200 μM and 1‐130 μM for D‐PA and CAP, respectively) as well as its experimental limit of detection can be achieved 0.8 μM, and 0.4 μM for D‐PA and CAP, respectively. The modified electrode for D‐PA and CAP determination is of the property of simple preparation, good stability and high sensitivity. Furthermore, the fabricated electrode was used to determine the content of D‐PA and CAP in the tablet, suggesting the good accuracy of the method.  相似文献   
5.
A new chemical sensor based on the measuring of circular dichroism signal (CD) was fabricated from cysteamine capped cadmium sulfide quantum dots (Cys-CdS QDs). The chiral-thiol molecules, d-penicillamine (DPA) and l-penicillamine (LPA), were used to evaluate potentials of this sensor. Basically, DPA and LPA provide very low CD signals. However, the CD signals of DPA and LPA can be enhanced in the presence of Cys-CdS QDs. The CD spectra of DPA and LPA exhibited a mirror image profile. Parameters affecting the determination of DPA and LPA were thoroughly investigated in details. Under the optimized condition, the CD signals of DPA and LPA displayed a linear relationship with the concentrations of both enantiomers, ranging from 1 to 35 μM. Detection limits of this sensor were 0.49 and 0.74 μM for DPA and LPA, respectively. To demonstrate a potential application of this sensor, the proposed sensor was used to determine DPA and LPA in real urine samples. It was confirmed that the proposed detection technique was reliable and could be utilized in a broad range of applications.  相似文献   
6.
L Song  Z Guo  Y Chen 《Electrophoresis》2012,33(13):2056-2063
A chiral capillary electrophoretic method with nearly full pH window was explored for the separation and determination of dl-penicillamine. A facile one-pot labeling technique was coupled in the method for introduction of chromophore and charge groups onto the analytes to facilitate the electromigration and sensitive detection. By using simply a cost-effective neutral β-cyclodextrin as chiral selector, baseline separation of the dl-penicillamine was achieved from pH 2.0 to over pH 10. Quantification of standard d- and l-penicillamines was demonstrated by taking pH 4.5, 7.4, and 9.7 as the representatives of acidic, neutral, and basic conditions. The working curves were constructed between peak area and concentration, having linear ranges of 8.56-8.56 × 10(2) μg/mL for pH 4.5 and 8.56-1.71 × 10(3) μg/mL for pH 7.4 and 9.7, with correlation coefficients all better than 0.999. The limit of detection (S/N = 3) was 2.58 μg/mL in acidic and neutral conditions or 1.41 μg/mL in basic condition. The method was further validated by assaying the commercial penicillamine tablets, applicable to quantification of the effective enantiomer and the trace impurity of l-penicillamine at a content of down to 0.2, 0.6, and 2.0% for pH 9.7, 4.5, and 7.4, respectively. The recovery determined by spiking technique was in a range from 93.1 to 105 %. The method is easily extendable to the analysis of other chiral amines or amino acids.  相似文献   
7.
Double‐stranded DNA and multiwalled carbon nanotube (MWNT) complex modified glassy carbon electrodes (DNA‐MWNT‐GCE) were employed to discriminate penicillamine (PA) enantiomers. Cyclic voltammetry, electrochemical impedance spectroscopy, atomic force microscopy and ultraviolet‐visible spectroscopy were used to characterize the enantioselective phenomenon. The results indicated that the binding effect between L ‐PA and DNA‐MWNTs was stronger than that of D ‐PA and DNA‐MWNTs. In addition, the influencing factors of the modified electrodes were systematically investigated. The modified electrodes exhibited a linear response towards PA enantiomers from 1.0×10?1 to 1.0×10?8 mol L?1 and detection limits of 3.1×10?9 and 3.3×10?8 mol L?1 for L ‐PA and D ‐PA, respectively.  相似文献   
8.
We report a simple and effective strategy for fabrication of the nanocomposite containing chitosan (CS) and multiwall carbon nanotube (MWNT) coated on a glassy carbon electrode (GCE). The characterization of the modified electrode (CS‐MWNT/GC) was carried out using scanning electron microscopy (SEM) and UV–vis absorption spectroscopy. The electrochemical behavior of CS‐MWNT/GC electrode was investigated and compared with the electrochemical behavior of chitosan modified GC (CS/GC), multiwalled carbon nanotube modified GC (MWNT/GC) and unmodified GC using cyclic voltammetry (CV) and electron impedance spectroscopy (EIS). The chitosan films are electrochemically inactive; similar background charging currents are observed at bare GC. The chitosan films are permeable to anionic Fe(CN)63?/4? (FC) redox couple. Electrochemical parameters, including apparent diffusion coefficient for the Fe(CN)63?/4? redox probe at FC/CS‐MWNT/GC electrode is comparable to values reported for cast chitosan films. This modified electrode also showed electrocatalytic effect for the simultaneous determination of D‐penicillamine (D‐PA) and tryptophan (Trp). The detection limit of 0.9 μM and 4.0 μM for D‐PA and Trp, respectively, makes this nanocomposite very suitable for determination of them with good sensitivity.  相似文献   
9.
Zheng ZX  Lin JM  Qu F  Hobo T 《Electrophoresis》2003,24(24):4221-4226
D-Penicillamine is demonstrated for the first time as a chiral ligand for the enantioseparation of dansyl amino acids based on ligand-exchange micellar electrokinetic chromatography (LE-MEKC). Copper(II) was used as the central ion in the ternary complex. The effect of surfactant on the resolution was significant. A concentration of 20 mM sodium dodecyl sulfate (SDS) was shown to be necessary for the separation. Other important parameters, such as the concentration ratio of D-penicillamine (D-PEN) to Cu2+, the kind of metal central ion, the type and pH value of buffer, were also investigated. N-Acetyl-D-penicillamine and L-valine (Val), with similar structure to D-penicillamine, were applied as their copper(II) complexes as chiral selector and the chiral recognition mechanism is briefly discussed. Under optimum experimental conditions, i.e., 20 mM NH4OAc, pH 6.5, a 2:1 concentration ratio of D-penicillamine to Cu(II), 4 mM CuSO4 and 8 mM D-penicillamine, the chiral separation of eight pairs of different dansyl amino acid enantiomers was accomplished with resolution ranging from 1.1 to 5.9. When L-PEN was used instead of D-PEN, reversal of the migration order was observed.  相似文献   
10.
Summary The chromatographic characteristics of the thiazolidine carboxylic acids formed by the reaction of D- and L-penicillamine with various substituted benzaldehydes and heterocyclic aldehydes have been studied on Chiralplate layers. It has been found that the nature and position of substituents strongly affect the RF values and resolution factors (RS) of the isomers. An unambiguous relationship has been established between the RS values of the L- and D-enantiomers and the dipole moment of the aldehydes. The transformation to thiazolidine carboxylic acids with benzaldehyde and substituted benzaldehydes, however, is not complete, thus the reaction with formaldehyde is still more suitable for quantitative determination of penicillamine isomers.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号