排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
A novel quartz device has been designed to trap arsine and selenium hydride and subsequently to volatilize the collected analyte
and atomize it for atomic-absorption spectrometric detection. The device is actually the multiple microflame quartz-tube atomizer
(multiatomizer) with inlet arm modified to serve as the trap and to accommodate the oxygen-delivery capillary used to combust
hydrogen during the trapping step. The effect of relevant experimental conditions (trap temperature during trapping and hydrogen
flow rate and trap temperature during volatilization) on collection and volatilization efficiency was investigated. Under
the optimum conditions collection and volatilization efficiency for arsenic and selenium were 50 and 70%, respectively.
相似文献
2.
Matoušek T Hernández-Zavala A Svoboda M Langrová L Adair BM Drobná Z Thomas DJ Stýblo M Dědina J 《Spectrochimica Acta Part B: Atomic Spectroscopy》2008,63(3):396-406
An automated system for hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer is described. Arsines are preconcentrated and separated in a Chromosorb filled U-tube. An automated cryotrapping unit, employing nitrogen gas formed upon heating in the detection phase for the displacement of the cooling liquid nitrogen, has been developed. The conditions for separation of arsines in a Chromosorb filled U-tube have been optimized. A complete separation of signals from arsine, methylarsine, dimethylarsine, and trimethylarsine has been achieved within a 60 s reading window. The limits of detection for methylated arsenicals tested were 4 ng l(-1). Selective hydride generation is applied for the oxidation state specific speciation analysis of inorganic and methylated arsenicals. The arsines are generated either exclusively from trivalent or from both tri- and pentavalent inorganic and methylated arsenicals depending on the presence of L-cysteine as a prereductant and/or reaction modifier. A TRIS buffer reaction medium is proposed to overcome narrow optimum concentration range observed for the L-cysteine modified reaction in HCl medium. The system provides uniform peak area sensitivity for all As species. Consequently, the calibration with a single form of As is possible. This method permits a high-throughput speciation analysis of metabolites of inorganic arsenic in relatively complex biological matrices such as cell culture systems without sample pretreatment, thus preserving the distribution of tri- and pentavalent species. 相似文献
3.
A novel modular L-shaped design of hydride atomizer for atomic absorption spectrometry is described. It makes it possible to replace the optical tube of the atomizer and, mainly, to employ optical tubes made also from other materials than fused quartz. The design is useful mainly for further improvement of hydride atomizers based on the multiatomizer concept. Employing selenium hydride as the analyte and arsine as the interferent, a preliminary evaluation of performance of three types of L-shaped multiatomizers based on various optical tubes in terms of sensitivity, linearity of calibration graph and resistance to atomization interferences is made. The “classical” T-shaped multiatomizer was employed as a reference.The L-shaped multiatomizer with the optical tube analogous to that employed in the “classical” T-shaped multiatomizer offers virtually the same performance as the reference multiatomizer. Optical tube made of fused quartz with holes with smaller diameters does not offer significantly better performance compared to the reference T-shaped multiatomizer. However, the L-shaped multiatomizer with optical tube fabricated from porous quartz glass overpowers all the other multiatomizers substantially in terms of the resistance against interferences: even the maximum As interferent concentration of 5 µg ml− 1 does not significantly influence the observed signal. This should be compared with multiatomizers based on plain fused quartz tubes with holes: tolerance limit around 0.5 µg ml− 1; interferent concentration of 1 µg ml− 1 causing 20% signal depression. 相似文献
1