首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   1篇
化学   25篇
物理学   2篇
  2022年   1篇
  2020年   2篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2012年   2篇
  2011年   3篇
  2010年   4篇
  2009年   2篇
  2007年   3篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2002年   1篇
  2001年   1篇
  1997年   1篇
排序方式: 共有27条查询结果,搜索用时 31 毫秒
1.
《Electroanalysis》2004,16(9):741-747
This work reports a technique for the rapid electrochemical detection of propranolol and metoprolol in pharmaceutical preparations using stabilized lipid films. Microporous filters composed of glass fibers (nominal pore sizes 0.7 and 1.0 μm) were used as supports for the formation and stabilization of these devices. The lipid film is formed on the filter by polymerization prior to its use. This stabilized after storage in air. Lipid films composed of phosphatidylcholine were used for the detection of propranolol and metoprolol in pharmaceutical preparations. The stabilized lipid membranes provided artificial ion gating events in the form of transient signals within about 60 and 34 s after exposure of the membranes to propranolol and metoprolol, respectively. The magnitude of the transient current signal was related to the concentration of propranolol and metoprolol in bulk solution in the micromolar range. The mechanism of signal generation was investigated by differential scanning calorimetric studies. These studies revealed that the adsorption of the drug is through the hydrophobic aryl terminal of the compound, whereas the hydrophilic groups were directed towards the electrolyte solution. This adsorption caused a rapid alteration of the electrochemical double layer of the lipid film (i.e., capacitance changes) that resulted in the transient ion current signal. The present technique was used for the rapid detection of propranolol and metoprolol in pharmaceutical preparations and can function for repetitive uses after storage in air. Future research is targeted to the determination of these chemicals in human biofluids such as urine of athletes.  相似文献   
2.
Summary A method for the assay of R-(+)- and S-(−)- metoprolol in human urine has been developed using gas chromatography-mass spectrometry. The method involved purification by liquid-liquid extraction and derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide to form an O-silyl ether, followed by subsequent chiral derivatization with (−)-α-methoxy-α-(trifluoromethyl)phenylacetyl chloride to form diastereomeric amide. The reaction was rapid and the diastereomeric derivatives were well resolved. Quantitation was performed by selected-ion monitoring of fragment ions of the diastereomers in electron impact ionization mode. No racemization was found during the reaction. The detection limit was 0.5 ng·mL−1. The intra-day variation ranged between 0.38 and 7.86% in relation to the measured concentration and inter-day variation was 2.26–8.06%. The method has been applied to the determination of R-(+)-and S-(−)- metoprolol in human urine from healthy volunteers dosed with racemic metoprolol tartrate.  相似文献   
3.
Aqueous-solution complexes of β-cyclodextrin (β-CD) with metoprolol tartrate (MET) have been analysed with 1H NMR and UV–vis spectroscopy. With 1H NMR a [1:1] stoichiometry could be established for the β-CD-MET complex while its stability constant was determined with UV–vis spectroscopy. Powder diffraction data of a polycrystalline sample of the β-CD-MET complex show that a novel product has been formed, likely to be a β-CD-MET [1:1] inclusion complex. Also Hyperchem MM+ molecular-dynamics results suggest an inclusion complex and from 1H NMR data it is inferred that probably the MET is docked in the CD with the formers methoxyethyl-benzene moiety in front. Mihaela Toma is Socrates/Erasmus student at UNED Madrid  相似文献   
4.
This research aims to fabricate and characterize chemically crosslinked CMC/PVP-co-poly (AMPS) based hydrogel for the sustained release of model drug metoprolol tartrate through the free radical polymerization technique. Box-Behnken Design was used to optimize CMC/PVP-co-poly (AMPS) hydrogel by varying the content of reactants such as; polymers (CMC and PVP), monomer (AMPS), and crosslinker (EGDMA). Carboxymethyl cellulose (CMC) was crosslinked chemically with AMPS with a constant ratio of PVP by the ethylene glycol dimethacrylate as the crosslinker in the presence of sodium hydrogen sulfite (SHS)/ammonium peroxodisulfate (APS) as initiators. After developing CMC-based hydrogels using different polymers, monomer, and crosslinker concentrations, this study encompassed dynamic swelling, sol–gel fraction, drug release and chemical characterizations such as FTIR, XRD, TGA, DSC, and SEM. In vitro drug release and swelling were performed at 1.2 and 6.8 pH to determine the sustained release pattern and pH-responsive behavior. These parameters depended on the crosslinker, polymer, and monomer ratios used in the formulation development. XRD, SEM, and FTIR showed the successful grafting of constituents resulting in the formation of a stable hydrogel. DSC and TGA confirmed the thermodynamic stability of the hydrogel. Hydrogel swelling was increased with an increase in the ratio of monomer; however, an increase in the ratio of polymer and crosslinker decreased the hydrogel swelling. In vitro gel fraction and drug release also depended on polymer, monomer, and crosslinker ratios. The fabricated CMC/PVP-co-poly (AMPS) hydrogels constituted a potential system for sustained drug delivery.  相似文献   
5.
提出了毛细管电泳手性拆分β-受体阻滞剂美托洛尔、阿普洛尔、卡替洛尔的方法。考察手性拆分剂的种类及浓度、缓冲溶液的浓度及pH对手性拆分的影响。在95mmol.L-1Tris-H3PO4缓冲溶液中添加15mmol.L-1羟丙基-β-环糊精(HP-β-CD)和5g.L-1羧甲基-β-环糊精(CM-β-CD),美托洛尔对映体和阿普洛尔对映体分别在pH3.2和pH3.8获得基线分离,卡替洛尔对映体在同一分离条件下在pH3.8获得较好分离,分离度达1.0。  相似文献   
6.
A series of modified SBA-15 materials were applied in drug delivery systems. The internal surface of siliceous hexagonal structure of SBA-15 was modified with different amount of (3-mercaptopropyl)trimethoxysilane (MPTMS) and oxidized in the presence of hydrogen peroxide. The sulfonated material was loaded with metoprolol tartrate or papaverine hydrochloride. Both drugs indicated strong chemical interaction with modified mesoporous surface. The characteristic of the obtained materials was performed with XRD and DRUV-vis spectrometry, themogravimetry and nitrogen adsorption (BET) measurements. The obtained results show that modification of the mesoporous materials leads towards significant decrease of the drug delivery rate.  相似文献   
7.
This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood.  相似文献   
8.
This work describes the development of an electrochemical sensor based on a new molecularly imprinted polymer for detection of metoprolol (MTP) at ultra-trace level. The polypyrrole (PPy) was electrochemically synthesized on the tip of a pencil graphite electrode (PGE) which modified whit functionalized multi-walled carbon nanotubes (MWCNTs). The fabrication process of the sensor was characterized by cyclic voltammetry (CV) and the measurement process was carried out by differential pulse voltammetry (DPV). A computational approach was used to screening functional monomers and polymerization solvent for rational design of molecularly imprinted polymer (MIP). Based on computational results, pyrrole and water were selected as functional monomer and polymerization solvent, respectively. Several significant parameters controlling the performance of the MIP sensor were examined and optimized using multivariate optimization methods such as Plackett–Burman design (PBD) and central composite design (CCD). Under the selected optimal conditions, MIP sensor was showed a linear range from 0.06 to 490 μmol L−1 MTP, a limit of detection of 2.88 nmol L−1, a highly reproducible response (RSD 3.9%) and a good selectivity in the presence of structurally related molecules. Furthermore, the applicability of the method was successfully tested with determination of MTP in real samples (tablet, and serum).  相似文献   
9.
模拟受体聚合物的合成及吸附行为研究   总被引:5,自引:2,他引:3  
采用紫外光引发聚合的分子印迹技术,分别制备阿替洛尔、美托洛尔、尼莫地平、酮糠唑4种模板化合物的分子印迹聚合物(molecularlyimprinted polymers,MIP).利用紫外平衡吸附法研究了聚合物的吸附性能和选择识别能力.结果表明,阿替洛尔、美托洛尔印迹聚合物对各自的模板分子呈现良好的再识别性能,而尼莫地平、酮糠唑印迹聚合物对原模板则几乎没有识别能力.Scatchard分析显示了功能单体甲基丙烯酸(MAA)与模板分子阿替洛尔、美托洛尔在自组装过程中通过氢键和离子键形成了至少两类不等价的结合位点.对底物交叉结合实验也表明阿替洛尔、美托洛尔这两种印迹聚合物具有良好的选择性,分离因子α值分别达到了1.75和1.62,而空白聚合物则分别仅为1.07和0.97.  相似文献   
10.
A kinetic spectrophotometric method has been described for the determination of metoprolol tartrate in commercial dosage forms. The procedure is based on the reaction of the drug with 1‐chloro‐2, 4‐dinitrobenzene (CDNB) in dimethylsulfoxide (DMSO) at 100 ± 1 °C. The reaction is investigated by measuring the change in absorbance with time at 420 nm. Fixed‐time (ΔA) and equilibrium methods are chosen for obtaining the calibration curves. Both calibration curves were found to be linear over the concentration range of 5‐60 μg mL?1. The regression analysis of calibration data resulted in the linear regression equations of ΔA = ?1.608 × 10?4 + 3.96 × 10?3 C and A = 7.31 × 10?4 + 1.90 × 10?2 C for fixed time (ΔA) and equilibrium methods, respectively. The limit of detection (LOD) for fixed time and equilibrium methods are 1.16 and 0.415 μg mL?1, respectively. The method has been successfully applied to the quantitation of metoprolol tartrate in commercial dosage forms. Statistical comparison of the results shows that there is no significant difference between the proposed methods and El‐Ries's spectrophotometric method.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号