首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   91篇
  免费   0篇
化学   13篇
力学   3篇
数学   4篇
物理学   71篇
  2023年   1篇
  2022年   1篇
  2021年   3篇
  2020年   1篇
  2018年   1篇
  2017年   1篇
  2016年   3篇
  2014年   4篇
  2013年   2篇
  2012年   7篇
  2011年   9篇
  2010年   4篇
  2009年   7篇
  2008年   11篇
  2007年   6篇
  2006年   4篇
  2005年   2篇
  2004年   3篇
  2003年   5篇
  2001年   1篇
  2000年   1篇
  1999年   3篇
  1998年   7篇
  1995年   1篇
  1994年   1篇
  1991年   2篇
排序方式: 共有91条查询结果,搜索用时 31 毫秒
1.
Hyperpolarized [1-13C]fumarate is a promising magnetic resonance imaging (MRI) biomarker for cellular necrosis, which plays an important role in various disease and cancerous pathological processes. To demonstrate the feasibility of MRI of [1-13C]fumarate metabolism using parahydrogen-induced polarization (PHIP), a low-cost alternative to dissolution dynamic nuclear polarization (dDNP), a cost-effective and high-yield synthetic pathway of hydrogenation precursor [1-13C]acetylenedicarboxylate (ADC) was developed. The trans-selectivity of the hydrogenation reaction of ADC using a ruthenium-based catalyst was elucidated employing density functional theory (DFT) simulations. A simple PHIP set-up was used to generate hyperpolarized [1-13C]fumarate at sufficient 13C polarization for ex vivo detection of hyperpolarized 13C malate metabolized from fumarate in murine liver tissue homogenates, and in vivo 13C MR spectroscopy and imaging in a murine model of acetaminophen-induced hepatitis.  相似文献   
2.
Accurate and efficient filtering techniques are required to suppress large nuisance components present in short-echo time magnetic resonance (MR) spectra. This paper discusses two powerful filtering techniques used in long-echo time MR spectral quantitation, the maximum-phase FIR filter (MP-FIR) and the Hankel-Lanczos Singular Value Decomposition with Partial ReOrthogonalization (HLSVD-PRO), and shows that they can be applied to their more complex short-echo time spectral counterparts. Both filters are validated and compared through extensive simulations. Their properties are discussed. In particular, the capability of MP-FIR for dealing with macromolecular components is emphasized. Although this property does not make a large difference for long-echo time MR spectra, it can be important when quantifying short-echo time spectra.  相似文献   
3.
Split RF coils offer improved patient access by eliminating the need for the coil to be slid over the region of interest. For unshielded birdcage coils, the presence of end ring currents necessitates a direct electrical connection between two halves of the coil. For high-field (>3T) shielded birdcage coils, both the shield and the coil must be split and reliably connected electrically. This problem can be circumvented by the use of split TEM volume coils. Since the elements of a TEM coil are coupled inductively, no direct electrical connection between the halves is necessary. In this work we demonstrate that the effects of splitting the shield for head and knee TEMs can be compensated for, and performance retained. For the knee, the improved access allowed the coil diameter to be reduced, enhancing the sensitivity by 15-20%.  相似文献   
4.
The muscle metabolism of at-rest patients with varying degrees of postpolio residual paralysis (PPRP) was studied and compared with that of controls using in vivo phosphorus magnetic resonance spectroscopy. The phosphocreatine (PCr)/inorganic phosphate (Pi) and PCr/adenosine triphosphate ratios were lower in patients than in controls. Reduction in PCr/Pi suggests abnormalities in oxidative phosphorylation. A significant increase was observed in the phosphomonoester/PCr ratio in patients, indicating the accumulation of intermediary compounds of the glycolytic pathway. Furthermore, the phosphodiester/PCr ratio was also significantly increased in patients. In general, the observed changes in metabolite ratios were found to be related to the degree of residual paralysis, suggesting that metabolic changes are secondary to chronic neurogenic processes. These metabolic alterations appear to be the possible cause of energy deficit and underlying muscle fatigue in PPRP patients. The present results provide an insight into the metabolic impairment and degree of muscle damage in patients with PPRP.  相似文献   
5.
基于QUEST定量检测1H MRS大脑代谢物的研究   总被引:1,自引:0,他引:1  
利用jMRUI时域分析软件模拟先验知识基础集定量检测1H MRS大脑代谢物. 通过模拟短TE=28 ms的1H MRS的多种代谢物基础集,经HLSVD奇异值分解滤除残余水峰,将先验知识应用在QUEST算法上对1H MRS大脑代谢物信号进行定量估计. 结果显示, 基于QUEST能有效获得1H MRS大脑代谢物的估计浓度. 表明引用先验知识基础集进行1H MRS定量分析可克服短TE时谱线复杂和波峰重叠峰等问题,极大地提取代谢物的信息.  相似文献   
6.
Focused pathological evaluation of axillary lymph nodes in breast cancer is gaining importance. Nuclear magnetic resonance (NMR) spectroscopy that assesses the whole of the specimen has the potential in evaluating micrometastases. The biochemical changes associated with breast cancer metastases in axillary nodes by in vitro NMR and its use in the detection of axillary metastases in a clinical setting in comparison with conventional histopathology is presented in this study. Eighty-eight lymph nodes obtained from 30 patients with breast cancer were investigated. Histopathology revealed metastases in 20 nodes from 11 patients, while in vitro NMR spectroscopy revealed metastases in 22 nodes. Out of these 22 nodes, 16 were the same, which showed metastases on histopathology, while 6 nodes have shown metastases only on in vitro magnetic resonance spectroscopy (MRS). These 6 nodes with suspicion of metastases on MRS were subjected to reevaluation with serial sectioning and immunohistochemistry, but no additional metastases were revealed. Forty metabolites could be identified from the MR spectrum of lymph nodes. The levels of the glycerophosphocholine-phosphocholine (GPC-PC), choline, lactate, alanine and uridine diphosphoglucose were elevated significantly in nodes with metastases. In addition, the intensity ratio of GPC-PC/threonine (Thr) was higher in nodes with metastases, and using this as marker, MRS detected the axillary metastases with a sensitivity, specificity and accuracy of 80%, 91% and 88%, respectively. Neoadjuvant chemotherapy (NACT) lowered the concentrations of GPC-PC and GPC-PC/Thr ratio. The accuracy of MRS in detecting metastases was 75% in patients who received NACT (n=9) as compared to 96% in those who did not (n=21). Our results demonstrate the potential of in vitro MRS in characterizing the metabolite profile of the axillary nodes with breast cancer metastases. It detected axillary metastases with reasonable accuracy and can be complementary to histopathological evaluation and immunohistochemistry.  相似文献   
7.
The analysis of information derived from magnetic resonance imaging (MRI) and spectroscopy (MRS) has been identified as an important indicator for discriminating among different brain pathologies. The purpose of this study was to investigate the efficiency of the combination of textural MRI features and MRS metabolite ratios by means of a pattern recognition system in the task of discriminating between meningiomas and metastatic brain tumors. The data set consisted of 40 brain MR image series and their corresponding spectral data obtained from patients with verified tumors. The pattern recognition system was designed employing the support vector machines classifier with radial basis function kernel; the system was evaluated using an external cross validation process to render results indicative of the generalization performance to “unknown” cases. The combination of MR textural and spectroscopic features resulted in 92.15% overall accuracy in discriminating meningiomas from metastatic brain tumors. The fusion of the information derived from MRI and MRS data might be helpful in providing clinicians a useful second opinion tool for accurate characterization of brain tumors.  相似文献   
8.
Gamma-aminobutyric acid (GABA) and glutamate (Glu) levels, normalized to total creatine (tCr), were measured in the anterior cingulate and cerebellar vermis in healthy adults (n=19, age=24.6±6.4 years) using 1H MRS at 3 T, and metabolite correlations across regions and subjects were determined. Mean anterior cingulate and cerebellar GABA/tCr ratios were 0.31 (0.08) and 0.23 (0.06), respectively, while corresponding Glu levels were 1.16 (0.10) and 0.70 (0.07), respectively. Anterior cingulate and cerebellar glutamate levels were correlated (r=0.6103, P=.0140), although it is noted that when adjusted for multiple comparisons, all correlations reported here cluster to a P value of .0583. It is unlikely that this correlation is driven by correlations in tCr, since interregional correlations were not observed for other metabolites referenced to tCr. Correlations were also observed among metabolites in both the anterior cingulate and cerebellar vermis. In the former, N-acetylasparate was linearly dependent on glutamate (r=0.6577, P=.0063) and, at or below this significance threshold, four metabolites were correlated in the cerebellar vermis (Ins/tCh: r=0.6261, P=.0109. NAA/tCh: r=0.6426, P=.0082. NAA/Glu: r=0.6412, P=.0085. tCh/Glu: r=0.6193, P=0.0122).  相似文献   
9.
《Composite Interfaces》2013,20(8):775-788
The incorporation of nanotube-covered fibers in continuous fiber/epoxy composites has been shown to influence the mechanical, electrical, and thermal properties of the composite. Increased interlaminar shear stress, flexural strength and modulus have been reported in such composites over composites containing bare fibers. In this study, the microstructure and interfacial shear strength (ISS) of continuous silicon carbide fiber/epoxy composites with and without nanotubes grown from the SiC fiber surface were investigated with micro-Raman spectroscopy (MRS) and microscopy. The fibers with nanotubes grown from the surface were found to have a reduced ISS compared with the bare fibers. Electron microscopy showed good wetting of epoxy in the nanotube forests, but poor attachment of the nanotube forests to the fibers. These results suggest that the mechanism leading to improvements in bulk composite properties is not due to an improvement in the fiber/matrix ISS.  相似文献   
10.
对实验动物肿瘤进行活体31P MRS研究首要的是有效地固定动物.本文初步研究了用噻胺酮麻醉后的小鼠S180肿瘤在麻醉过程中31P MRS随时间的变异性.研究发现噻胺酮是一个安全系数高、起效快、麻醉过程适宜且对肿瘤的31P MRS无显著影响的麻醉药.因而噻胺酮适用于连续测定31P MRS的需要.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号