首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   1篇
  国内免费   2篇
化学   39篇
数学   1篇
物理学   8篇
  2022年   1篇
  2021年   1篇
  2020年   1篇
  2019年   1篇
  2017年   3篇
  2016年   2篇
  2015年   2篇
  2014年   1篇
  2013年   1篇
  2012年   6篇
  2011年   6篇
  2010年   1篇
  2009年   2篇
  2008年   4篇
  2006年   5篇
  2005年   1篇
  2004年   3篇
  2003年   1篇
  2002年   2篇
  2001年   2篇
  1999年   1篇
  1998年   1篇
排序方式: 共有48条查询结果,搜索用时 15 毫秒
1.
Internal audits inherently effect quality improvement, and concrete results can be expected by careful planning. As audits should improve the quality system in situ, the development of audits should not be neglected. ISO/IEC 17025 describes the objectives of internal audits and management reviews in more detail compared to the former standards EN 45001 and ISO/IEC Guide 25, although the main features are unchanged. This addresses continuous surveillance of the current practice. A brief questionnaire on vertical audits was distributed to 74 of 120 employees at a Finnish private medical laboratory, Medix Laboratories Ltd. A positive feed-back was received from the current management of audits. However, the study revealed that continuous supervision of audits is needed. Many employees were not willing to perform audits if they had no previous experience. Additionally, audits performed at the workbench were not considered as the best possible for fruitful discussions. Received: 20 February 2001 Accepted: 30 November 2001  相似文献   
2.
Medical laboratories of the public sector as well as of the private sector on the island of Mauritius are preparing for accreditation. The clinical laboratory of the Central Health laboratory of the Ministry of Health and Quality of Life has undergone a pre-assessment by experts of the International Atomic Energy Agency (IAEA) through the aegis of a project targeted to members of the Africa Region. Several shortcomings were identified and respective corrective actions were recommended for implementation within a given time frame. In addition to ensuring the competence of the laboratory, accreditation has various positive aspects such as an increased awareness of the staff to quality and better training opportunities. The pre-assessment exercise has provided a gap analysis, which is an important aspect in the preparation towards accreditation.  相似文献   
3.
 Confidence in laboratory operations is discussed based on the ongoing revision of the ISO/IEC Guide 25. Confidence is a subjective attribute, which also depends on whose interest is considered. New and better-defined quality systems and technical elements will be included, and these are beneficial to the transparency of laboratory operations, as well as to the accreditation process. The ultimate aim is, of course, to satisfy customers. The testing laboratories' industrial customers are, however, generally unfamiliar with the ISO/IEC Guide 25 and accreditation. The main reason for improved confidence in testing and calibration laboratories is foreseen to come from closer interaction between laboratories and their customers.  相似文献   
4.
In the view of the Deutscher Kalibrierdienst (DKD) , a certifying body for reference materials can be considered to be a calibration laboratory. Therefore, accreditation of calibration laboratories in accordance with ISO/IEC 17025 is the most appropriate way to establish confidence in certificates for reference materials. If necessary, the criteria of ISO/IEC 17025 can be tailored to specific cases. There is no need to provide any new kind of reference-material specific accreditation. However, in view of the variety of reference materials and the practice existing in other countries, accreditation of testing laboratories and product certification bodies may optionally be acceptable as long as the same stringent principles with respect to traceability and measurement uncertainty are applied. Such accreditations but not accreditations of reference material producers (ISO Guide 34) are also covered by existing international mutual recognition arrangements (MRA).  相似文献   
5.
基于2005版《计量认证/审查认可(验收)评审准则》要求,为满足环境监测实验室业务流程而设计开发了信息管理系统。该系统主要用于环境监测实验室的资源管理和日常自动化办公。系统采用B/S架构,实现全球化办公运作,能对监测样品的受理、分发、分析、原始记录、监测报告、数据三级审核、报告签发实现全程自动流转,并运用工作流和智能表单设计实现实验室程序文件中各类程序和日常办公事务流程的执行;原始记录和监测报告全部实现自动归档及智能查询;同时根据2005版准则中的要求,对人员、设备、材料、环境要素、记录、质量控制等所有要素全面实施网络化管理。  相似文献   
6.
The determination of seven arsenic species in seafood was performed using ion exchange chromatography on an IonPac AS7 column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The effect of five parameters on arsenic extraction recoveries was evaluated in certified reference materials. The recoveries of total arsenic and of arsenic species with the two best extraction media (100% H2O and 80% aqueous MeOH) were generally similar in the five seafood certified reference materials considered. However, because MeOH co-elutes with arsenite, which would result in a positively biased arsenite concentration, the 100% H2O extraction conditions were selected for validation of the method. Figures of merit (linearity, LOQs (0.019-0.075 mg As kg−1), specificity, trueness (with recoveries between 82% (As(III)) and 104% (As(V) based on spikes or certified concentrations), repeatability (3-14%), and intermediate precision reproducibility (9-16%) of the proposed method were satisfactory for the determination of arsenite, monomethylarsonic acid, dimethylarsinic acid, arsenate, arsenobetaine and arsenocholine in fish and shellfish. The performance criteria for trimethylarsine oxide, however, were less satisfactory. The method was then applied to 65 different seafood samples. Arsenobetaine was the main species in all samples. The percentage of inorganic arsenic varied between 0.4-15.8% in shellfish and 0.5-1.9% at the utmost in fish. The main advantage of this method that uses only H2O as an extractant and nitric acid as gradient eluent is its great compatibility with the long-term stability of both IEC separation and ICP-MS detection.  相似文献   
7.
A statistical analysis of findings in assessments by an accreditation body, external audits and internal audits in an accredited testing laboratory for gamma-ray spectrometry is presented. The frequencies of observations reported in different areas were examined and analysed. The differences are interpreted in terms of the varying importance associated with the different areas as perceived by auditors and assessors.  相似文献   
8.
The GE Senographe DS digital mammography system includes a preprocessing algorithm called FineView designed to improve spatial resolution. The effect of FineView on modulation transfer function MTF, normalized noise power spectrum NNPS, and detective quantum efficiency DQE has been measured by some authors under different experimental conditions and their results do not always agree. We have evaluated the effect of FineView on these functions under rigorous standard conditions, following the 2007 IEC guidelines for DQE measurement in digital mammography detectors. We have also investigated the impact on DQE of the use of different beam spectra and the presence of the anti-scatter grid. Measurements were made with Mo/Mo, 28 kV operating voltage, and 2 mm Al at tube exit. MTF was obtained with the edge method, detector air-kerma DAK levels ranged from 60 to 272 μGy, and the grid was set in or out, depending on the measurement. DQE values showed a dependence on DAK but were not significantly affected by FineView. The effect of the grid on DQE was of the order of 2% average difference and considered nonsignificant, while no effect of beam quality on DQE was observed at 200 μGy, and 6% average difference was observed between 18.5 and 19.4 keV mean energies at 60 μGy, also considered nonsignificant.  相似文献   
9.
An optional approach in the meteorological service Quality Management System (QMS) based on the case study of the Republic Hydrometeorological Service (MHS) of Serbia is presented and discussed in this paper. The idea is to use the ISO/IEC 17025 standard as a base for its QMS development. Main reasons for such a decision and the elements of the implemented solution are presented and discussed. Meteorological testing processes of the MHS of Serbia and relevant ISO/IEC 17025 scope of accreditation are presented. After establishing competencies in meteorological, environmental, and hydrological testing, the MHS of Serbia will develop an integrative ISO 9001 QMS. The Serbian case study could be taken into consideration as one of the options related to the future World Meteorological Organization Quality Management Framework.  相似文献   
10.
In this study, novel poly(imide-ethylene glycol) (PIEG) was prepared via polycondensation of ethylenediaminetetraacetic dianhydride, 4-aminophenyl sulfone, and poly(ethylene glycol) bis(amine). Later, thermally stable and mechanically robust undoped and acid-doped proton exchange membranes were prepared using the graphene oxide (GO) nanofiller. Field emission scanning electron microscope revealed a unique hexagonal imprinted morphology of the fractured surface. Increasing the GO content from 1 to 5 wt% increased tensile strength (59.7–65.9 MPa) and the modulus (20.3–23.9 GPa) of the undoped PIEG/GO series. Thermal properties of the undoped PIEG/GO 1–5 membranes were also higher, i.e., T10 = 438–487°C. However, dop-PIEG/GO 1–5 membranes have a higher ion exchange capacity (IEC) of 2.4–2.9 mmol/g and proton conductivity 1.8–2.7 S cm?1 (94% RH).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号