首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
化学   5篇
  2012年   1篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2003年   1篇
排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
A simple capillary zone electrophoresis method was developed for the quantitative enantiomeric analysis of piperazine antihistamines with teratogenic suspicion in animals. Enantioseparation of chlorcyclizine, hydroxyzine, and meclizine was performed in glycine buffer (0.6 mol L-1; pH 3.00) with sulfated -cyclodextrin (5 mg mL-1) as a chiral selector; and the separated drugs were monitored by ultra-violet detector. The lower quantitation of the individual enantiomer is attainable at 10 µmol L-1, using an achiral piperazine drug (cyclizine) as internal standard. The method is simple and rapid with a short run time (<5 min) for the analysis of chlorcyclizine, hydroxyzine or meclizine enantiomers.  相似文献   
2.
Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. In this work, a biomimetic potentiometric sensor, based on a non-covalent imprinted polymer, was fabricated for the recognition and determination of hydroxyzine in tablets and biological fluids. The molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization, using hydroxyzine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensor showed a high selectivity and a sensitive response to the template in aqueous system. The MIP-modified electrode exhibited a Nernstian response (29.4 ± 1.0 mV decade−1) in a wide concentration range of 1.0 × 10−6 to 1.0 × 10−1 M with a lower detection limit of 7.0 × 10−7 M. The electrode demonstrated a response time of ∼15 s, a high performance and a satisfactory long-term stability (more than 5 months). The method has the requisite accuracy, sensitivity and precision to assay hydroxyzine in tablets and biological fluids.  相似文献   
3.
In this work, two-step hollow fiber-based liquid-phase microextraction procedure was evaluated for extraction of the zwitterionic cetirizine (CTZ) and basic hydroxyzine (HZ) in human plasma. In the first step of extraction, the pH of sample was adjusted at 5.0 in order to promote liquid-phase microextraction of the zwitterionic CTZ. In the second step, the pH of sample was increased up to 11.0 for extraction of basic HZ. In this procedure, the extraction times for the first and the second steps were 30 and 20 min, respectively. Owing to the high ratio between the volumes of donor phase and acceptor phase, CTZ and HZ were enriched by factors of 280 and 355, respectively. The linearity of the analytical method was investigated for both compounds in the range of 10-500 ng mL(-1) (R(2) > 0.999). Limit of quantification (S/N = 10) for CTZ and HZ was 10 ng mL(-1) , while the limit of detection was 3 ng mL(-1) for both compounds at a signal to noise ratio of 3:1. Intraday and interday relative standard deviations (RSDs, n = 6) were in the range of 6.5-16.2%. This procedure enabled CTZ and HZ to be analyzed simultaneously by capillary electrophoresis.  相似文献   
4.
Hydroxyzine hydrochloride forms two 1:1 inclusion complexes with β‐cyclodextrin in aqueous solution as confirmed by the 1H NMR titration and ROESY studies. One complex is formed by the deep penetration of the chlorophenyl ring from the wider rim side, while the mode of entry of the phenyl ring into the β‐CD cavity is not clear. The stoichiometry and overall association constant of the complexes have been determined by the treatment of 1H NMR shift data. Some chiral discrimination by the host between the two enantiomers of hydroxyzine hydrochloride is also indicated.  相似文献   
5.
A rapid, simple and specific liquid chromatography-electrospray ionization mass spectrometry method has been developed and validated for the determination of hydroxyzine hydrochloride in human plasma. Samples were separated using a Thermo Hypersil-HyPURITYC18 reversed-phase column (150 mm × 2.1 mm i.d., 5 μm). The mobile phase consisted of 50 mM ammonium acetate (pH 4.0)–methanol–acetonitrile (45:36:19, v/v). Hydroxyzine and its internal standard were measured by electrospray ion source in positive selective ion monitoring mode. The method was validated with a linear range of 1.56–200.0 ng mL−1 and the lowest limit of quantification was 1.56 ng mL−1 for hydroxyzine hydrochloride (r 2= 0.9991). The extraction efficiencies were about 70% and recoveries of the method were in the range of 93.5–104.4%. The intra-day relative standard deviation (RSD) was less than 8.0% and inter-day RSD was within 7.4%. QC samples were stable when kept at ambient temperature for 12 h at −20 °C for 30 days and after four freeze–thaw cycles. The method has been successfully applied to the evaluation of pharmacokinetics and bioequivalence of two hydroxyzine hydrochloride formulations in 12 healthy Chinese volunteers after an oral dose of 25 mg.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号