首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   219篇
  免费   7篇
  国内免费   2篇
化学   195篇
力学   7篇
数学   4篇
物理学   22篇
  2022年   4篇
  2021年   4篇
  2020年   7篇
  2019年   3篇
  2018年   6篇
  2017年   11篇
  2016年   7篇
  2015年   12篇
  2014年   8篇
  2013年   16篇
  2012年   21篇
  2011年   39篇
  2010年   30篇
  2009年   20篇
  2008年   13篇
  2007年   10篇
  2006年   2篇
  2005年   8篇
  2004年   3篇
  2003年   1篇
  1999年   2篇
  1989年   1篇
排序方式: 共有228条查询结果,搜索用时 15 毫秒
1.
In the present work we describe a two‐dimensional liquid chromatographic system (2D‐LC) with detection by mass spectrometry (MS) for the simultaneous separation of endogenous metabolites of clinical interest and excreted xenobiotics deriving from exposure to toxic compounds. The 2D‐LC system involves two orthogonal chromatographic modes, hydrophilic interaction liquid chromatography (HILIC) to separate polar endogenous metabolites and reversed‐phase (RP) chromatography to separate excreted xenobiotics of low and intermediate polarity. Additionally, the present proposal has the novelty of incorporating an on‐line sample treatment based on the use of restricted access materials (RAMs), which permits the direct injection of urine samples into the system. The work is focused on the instrumental coupling, studying all possible options and attempting to circumvent the problems of solvent incompatibility between the RAM device and the two chromatographic columns, HILIC and RP. The instrumental configuration developed, RAM‐HILIC‐RPLC‐MS/MS, allows the simultaneous assessment of urinary metabolites of clinical interest and excreted compounds derived from exposure to toxic agents with minimal sample manipulation. Thus, it may be of interest in areas such as occupational and environmental toxicology in order to explore the possible relationship between the two types of compounds. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
2.
A sensitive, simple, fast and rugged hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the determination of paroxetine was developed and validated over curve range 0.050-50 ng/mL using only 0.4 mL plasma. This is the first published LC-MS/MS method and the low limit of quantitation of this method is 10-fold lower than previously published methods. A simple liquid-liquid extraction method using methyl-tert butyl ether (MTBE) as the extraction solvent was used to extract paroxetine and the internal standard (IS) fentanyl-d(5) from plasma. The extract was evaporated to dryness, reconstituted and injected onto a silica column using a low aqueous-high organic mobile phase. The chromatographic run time was 2.0 min per injection, with retention times of 1.1 and 1.2 min for paroxetine and IS, respectively. The detection was by monitoring paroxetine at m/z 330 --> 192 and IS at m/z 342 --> 188, respectively. The inter-day precision and accuracy of the quality control (QC) samples were <5.0% relative standard deviation (RSD) and <2.9% relative error (RE). This method can be used for supporting therapeutical drug monitoring and pharmacokinetic or drug-drug interaction studies.  相似文献   
3.
A rapid and reproducible hydrophilic liquid chromatography (HILIC) process was established for concomitant determination of remogliflozin etabonate (RE), vildagliptin (VD), and metformin (MF) in a formulation. A face-centered central composite experimental design was employed to optimize and predict the chromatographic condition by statistically studying the surface response model and design space with desirability close to one. A HILIC column with a simple mobile phase of acetonitrile (65% v/v) and 20 mM phosphate buffer (35% v/v, pH 6, controlled with orthophosphoric acid) was used to separate RE, VD, and MF. RE, VD, and MF were separated in 3.6 min using an isocratic mode mobile phase flow at a flow rate of 1.4 mL at room temperature, and the analytes were examined by recording the absorption at 210 nm. The developed HILIC method was thoroughly validated for all parameters recommended by ICH, and linearity was observed in the ranges 20–150 µg/mL, 10–75 µg/mL, and 50–750 µg/mL for RE, VD, and MF, respectively, along with excellent regression coefficients (r2 > 0.999). The calculated percentage relative deviation and relative error ascertained the precision and accuracy of the method. The selectivity and accuracy were further confirmed by the high percentage recovery of added standard drugs to the formulation using the standard addition technique. The robustness of the HILIC processes was confirmed by developing a half-normal probability plot and Pareto chart, as the slight variation of a single factor had no significant influence on the assay outcomes. Utilization of the optimized HILIC procedure for concurrent quantification of RE, VD, and MF in solid dosage forms showed accurate and reproducible results. Hence, the fast HILIC method can be regularly employed for the quality assurance of pharmaceutical preparations comprising RE, VD, and MF.  相似文献   
4.
Paralytic shellfish toxins (PSTs), including gonyautoxins and saxitoxins, are produced by multiple species of microalgae and dinoflagellates, and are bioaccumulated by shellfish and other animals. Human exposure to PSTs typically occurs through ingestion of recreationally harvested contaminated shellfish and results in nonspecific symptomology. Confirmation of exposure to PSTs has often relied on the measurement of saxitoxin, the most toxic congener; however, gonyautoxins (GTXs), the sulfated carbamate derivatives of saxitoxin, may be present in shellfish at higher concentrations. To improve identification of PST exposures, our group has developed an online solid phase extraction hydrophilic interaction liquid chromatography method to identify GTX1–4 in human urine with tandem mass spectrometry. The reportable range varied for each analyte, with all falling within 0.899 and 250 ng/mL in urine with precision <15% and >85% accuracy as determined for all quality control samples. This new online method quantitates GTX1–4 following exposures to PSTs, supporting the work of public health authorities.  相似文献   
5.
Ascorbic acid (AA) is one of the essential nutrients in bee pollen, however, it is unstable and likely to be oxidized. Generally, the oxidation form (dehydroascorbic acid (DHA)) is considered to have equivalent biological activity as the reduction form. Thus, determination of the total content of AA and DHA would be more accurate for the nutritional analysis of bee pollen. Here we present a simple, sensitive, and reliable method for the determination of AA, total ascorbic acids (TAA), and DHA in rape (Brassica campestris), lotus (Nelumbo nucifera), and camellia (Camellia japonica) bee pollen, which is based on ultrasonic extraction in metaphosphoric acid solution, and analysis using hydrophilic interaction liquid chromatography (HILIC)-ultraviolet detection. Analytical performance of the method was evaluated and validated, then the proposed method was successfully applied in twenty-one bee pollen samples. Results indicated that contents of AA were in the range of 17.54 to 94.01 µg/g, 66.01 to 111.66 µg/g, and 90.04 to 313.02 µg/g for rape, lotus, and camellia bee pollen, respectively. In addition, percentages of DHA in TAA showed good intra-species consistency, with values of 13.7%, 16.5%, and 7.6% in rape, lotus, and camellia bee pollen, respectively. This is the first report on the discriminative determination between AA and DHA in bee pollen matrices. The proposed method would be valuable for the nutritional analysis of bee pollen.  相似文献   
6.
《Analytical letters》2012,45(15):2125-2135
A rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with hydrophilic interaction chromatography has been developed and validated for the simultaneous determination of isoniazid and acetylisoniazidin human plasma. Following precipitation of the protein, the analytes were extracted from human plasma, with high extraction recovery (>70%) for both Isoniazid and acetylisoniazid. The analytes were then separated using a hydrophilic interaction chromatography (HILIC) column and detected by electrospray ionization (ESI) mass spectrometry performed with a triple-quadrupole mass spectrometry. The quantification of the analytes was realized by low-energy collision dissociation tandem mass spectrometry (CID-MS/MS) using the multiple reaction monitoring (MRM) mode at m/z of 138.1→121.1 for isoniazid and m/z 180.1 → 138.1 for acetylisoniazid, respectively. The method was linear over the concentration range of 5–50,000 ng/mL for both. The intra-day and inter-day relative standard deviations (RSD) were less than 15% and the relative errors (RE) were all within 15%. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic studies of isoniazid related to NAT2 genetic polymorphism in healthy Chinese subjects. The results showed that there were significant differences in the pharmacokinetic parameters of isoniazid and acetylisoniazid between subjects with and without mutations in the NAT2 gene.  相似文献   
7.
建立了测定人尿液和自来水中4种碳青霉烯类抗生素(比阿培南、美罗培南、多利培南和厄他培南)的亲水作用色谱方法,所用流动相具有较好的质谱兼容性,可用于色谱-质谱联用。以XAmide为色谱柱,考察了乙腈比例、缓冲盐浓度和pH值对4种抗生素保留的影响,提出了可能的保留机理;所发展的方法对目标样品具有良好的线性响应:比阿培南、多利培南和厄他培南的线性范围为0.1~250 mg/L, R2=0.9999;美罗培南的线性范围为0.5~250 mg/L, R2=0.9998; 4种抗生素的定量限(LOQ)为0.1~0.5 mg/L。尿液样品和自来水样品在5 mg/L和25 mg/L两个水平的加标回收率分别为100.4%~111.9%和79.6%~107.4%,相对标准偏差(RSD)分别不大于1%和5%。该方法准确、灵敏、简便,可用于人尿液和自来水中多种碳青霉烯类抗生素的检测。  相似文献   
8.
邢倩倩  傅青  金郁  梁鑫淼 《色谱》2014,32(7):767-772
建立了亲水/反相二维色谱用于制备桔梗中三萜皂苷单体的方法。桔梗经水煮醇沉、反相和亲水两种模式的固相萃取后得到三萜皂苷类组分。选定XAmide色谱柱(150 mm×20 mm,5 μm),以乙腈和水为流动相,在亲水色谱模式下进行组分制备。选择时间触发模式,以1 min为单位进行馏分收集,得到6~25 min之间的20个三萜皂苷精细组分。以第18个馏分(JG23)为例,在反相色谱模式下采用Atlantis Prep T3色谱柱(100 mm×30 mm,5 μm)制备,得到两个单体化合物。通过质谱和核磁共振对其进行定性,确定分别为deapi-platycoside E和platycoside E。实验结果表明,该制备方法具有好的正交选择性,对于复杂样品中三萜皂苷类化合物的分离纯化有一定的借鉴意义。  相似文献   
9.
The retention behavior of several series of free α‐ and ω‐amino acids and positional isomers of amino pentanoic acid in the hydrophilic interaction chromatography mode (HILIC) was studied. The study was carried out on three stationary phases followed by post‐column derivatization with fluorescence detection in order to describe the retention mechanism of the tested amino acids. The effect of chromatographic conditions including acetonitrile content in the mobile phase, mobile phase pH (ranging from 3.5 to 6.5) and concentration of buffer in the mobile phase was investigated. The effect of the number of carbon atoms (nC) in aliphatic chains of the individual homologue of α‐ and ω‐amino acids and the logarithm of the partition coefficient (logD) on retention was also a part of the presented study. A good correlation (r > 0.98) between the logk and logD values of amino acids or nC, respectively, was observed. The described linear relationships were subsequently applied to predict the retention behavior of individual members of the homologous series of amino acids and to optimize the mobile phase composition in HILIC. The obtained results confirmed that the retention mechanism of α‐amino acids, ω‐amino acids and positional isomers of amino acids was based on the logD values and the number of carbon atoms in the aliphatic chains of amino acids. The elution order of ω‐amino acids and positional isomers of amino pentanoic acid was strongly dependent on the mobile phase pH in the investigated range whereas the retention factors of all α‐amino acids remained essentially unchanged on all tested stationary phases.  相似文献   
10.
Monolithic columns were introduced in the early 1990s and have become increasingly popular as efficient stationary phases for most of the important chromatographic separation modes. Monoliths are functionally distinct from porous particle-based media in their reliance on convective mass transport. This makes resolution and capacity independent of flow rate. Monoliths also lack a void volume. This eliminates eddy dispersion and permits high-resolution separations with extremely short flow paths. The analytical value of these features is the subject of recent reviews. Nowadays, among other types of rigid macroporous monoliths, the polymethacrylate-based materials are the largest and most examined class of these sorbents. In this review, the applications of polymethacrylate-based monolithic columns are summarized for the separation, purification and analysis of low and high molecular mass compounds in the different HPLC formats, including micro- and large-scale HPLC modes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号