首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   0篇
化学   2篇
  2019年   1篇
  2011年   1篇
排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
Abstract

The recovery of antioxidants from basil (Ocimum basilicum L.) was modeled with the aid of response surface methodology (RSM) using microwave-assisted extraction (MAE). Face-centered central design (FCCD) was employed to optimize the MAE operational parameters including the extraction time (1 to 7?min), extraction temperature (30 to 120?°C), solid-to-solvent ratio (0.1 to 0.4), and solvent concentration (20 to 80% ethanol, v/v), and to obtain the best possible combinations of these parameters for a high antioxidant yield from basil. The total antioxidant capacity (TAC) was expressed in trolox (TR) equivalents per gram of dried sample (DS). Three of the operational parameters (temperature, extraction time and solvent concentration) were shown to have significant effect on the extraction efficiency of antioxidants in basil extracts (p?<?0.05). The solvent concentration was shown to be the most significant factor on antioxidant yield obtained by MAE. There was a close relationship between experimental and predicted values using the proposed method. This optimized MAE method shows an application potential for the efficient extraction of antioxidants from basil in the food and pharmaceutical industries.  相似文献   
2.
Microfluidic LC systems present undeniable advantages over classical LC in terms of sensitivity. Hepcidin, a peptide marker of clinical disorders linked to iron metabolism, was used as model to demonstrate peptide quantification potentialities of LC-chip coupled to a nanoelectrospray source ion trap mass spectrometer in an aqueous sample. First, stable isotope labelled hepcidin was chosen as internal standard and gradient as well as sample compositions were optimised using design of experiments as development tool. The method was then prevalidated using accuracy profiles in order to select the most appropriate response function and to confirm the ability of the technique to quantify low hepcidin concentration. A reliable and very sensitive quantitation method was finally obtained using this integrated microfluidic technology. Indeed, good results with respect to accuracy, trueness and precision were achieved, as well as a very low limit of quantitation (0.07 ng/ml). Method suitability of nano-LC on chip tandem mass spectrometry for hepcidin quantitation was also demonstrated in complex media such as human plasma.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号