首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   4篇
  2016年   1篇
  2011年   2篇
  2007年   1篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Extractive electrospray ionization source(EESI)was adapted for ion-ion reaction,which was demonstrated by using a linear quadrupole ion trap mass spectrometer for the first ion-ion reaction of biopolymers in the atmospheric pressure ambient.  相似文献   
2.
Polycyclic aromatic hydrocarbons (PAHs) are a group of ubiquitous environmental contaminants raising worldwide concerns due to their carcinogenic effects. In this study, 1-hydroxypyrene (1-OHP, the most widely used biomarker of internal dose of PAHs exposure) in undiluted human urine samples (10 mL) was selectively enriched by polypyrrole-coated Fe3O4 magnetite nanocomposites (termed as Fe3O4@Ppy, 1 mg) and then directly eluted by the electrospraying solvent (acetone/benzene/acetic acid (v/v/v, 90/10/1); 100 uL) biased with −3.5 kV to produce the deprotonated 1-OHP anions for mass spectrometric analysis. The method established here significantly improved the current performance for detection of urinary 1-OHP, providing the speed for a single sample analysis within 4 min, the limits of detection (LOD) of 0.0001 μg L−1, the linear response range of 0.001–5.000 μg L−1 (R2 = 0.9994), recovery rates of 90.6–96.1%, and relative standard deviation (RSD, n = 6) values between 2.9% and 8.0%. Human samples including raw human urine collected from 10 healthy volunteers (5 smokers and 5 nonsmokers) and 7 lung cancer patients have been successfully analyzed, showing that magnetic solid-phase extraction (MSPE) coupled with internal extractive electrospray ionization mass spectrometry (iEESI-MS) is an alternative strategy for high throughput quantitative detection of urinary 1-OHP for health risk assessment of PAHs exposure.  相似文献   
3.
A sensitive method based on a geometry-independent neutral desorption (GIND) in combination with extractive electrospray ionization mass spectrometry (EESI-MS) has been developed for fast detection of illicit additives such as sulfonamides and hormones in highly viscous cosmetic products. The method gave a low limit of detection (LOD) (in the range of 0.001-1 ng/g), acceptable relative standard deviation (RSD=6.8-11.4%) and reasonable recovery (87-116%) for direct measuring of nine types of hormones and sulfonamides in the cosmetic products. The average measurement time for two types of samples was less than 1 min. Trace amounts of analytes in commercial cosmetic products have been quantitatively detected, without any sample pretreatment. The experimental results showed that non-volatile illicit additives such as sulfonamides and hormones could be sensitively liberated using the GIND device for quantitative detection from the highly viscous cosmetic products, demonstrating that GIND-EESI-MS is a promising tool for high throughput, sensitive and quantitative analysis of highly complex viscous samples.  相似文献   
4.
Zhang X  Liu Y  Zhang J  Hu Z  Hu B  Ding L  Jia L  Chen H 《Talanta》2011,85(3):1665-1671
High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD = 8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号