首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   19篇
  免费   0篇
化学   19篇
  2016年   1篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2009年   4篇
  2008年   1篇
  2007年   2篇
  2006年   2篇
  2004年   5篇
  2003年   1篇
排序方式: 共有19条查询结果,搜索用时 15 毫秒
1.

Specific polyclonal antibodies towards acetochlor (2-chloro- N -(ethoxymethyl)- N -(2-ethyl-6-methylphenyl)acetamide) were obtained from rabbits immunized against a 3-mercaptopropionic acid derivative of acetochlor, covalently attached to bovine serum albumin. A polarization fluoroimmuoassay (PFIA) based on these antibodies was developed and optimized to detect acetochlor in water samples. The optimized PFIA had a detection limit of 9 µg/L, linear working range from 50 to 5500 µg/L and within-assay coefficient of variation less than 4%. Cross-reactivity studies demonstrated that these antibodies are capable of specific detection of acetochlor amongst structurally related chloroacetanilide herbicides. Assay cross-reactivity values were: alachlor 0%, metolachlor 2.4%, propachlor 0%, butachlor 0.2% and dimethachlor 0.5%. Five organic solvents commonly used in sample extraction were evaluated for their effect on acetochlor PFIA performance, and methanol and ethanol were found to be compatible with the assay up to 10% v/v.  相似文献   
2.
Polyclonal antibodies were produced to detect 3-amino-2-oxazolidinone (AOZ), a stable metabolite of the nitrofuran antibiotic furazolidone, following derivatisation with o-nitrobenzaldehyde. A carboxyphenyl derivative of AOZ was prepared, purified and conjugated to immunogenic carrier protein. Six antisera were produced from the immunisation of seven rabbits using various immunogen doses and time-scales. IC50 values, as determined by competitive enzyme-linked immunosorbent assay (ELISA) suggested that reducing immunogen dose from 0.3 to 0.05 mg, while lengthening rest periods between booster immunisations from 2 to 8 weeks, increased the sensitivity of the antibodies to 3-{[(2-nitrophenyl)methylene]amino}-2-oxazolidinone (NPAOZ) from 3.8 to 0.3 μg l−1. An IC50 of 0.065 μg l−1 (AOZ in the form of NPAOZ) was achieved with antiserum R670 by altering ELISA conditions. This antibody was highly specific for NPAOZ and did not cross-react with various nitrofuran metabolites, their nitrophenyl derivatives or a range of veterinary drugs. Antibody R670 is suitable for incorporation into an immunoassay for AOZ with sufficient sensitivity to satisfy current criteria for monitoring of veterinary drug residues. This is the first publication of an antibody for detection of a nitrofuran metabolite.  相似文献   
3.
The development of express method for detection of endocrine-disrupting chemicals (EDC) such as alkylphenols is required for ecological monitoring. Several attempts have been made to produce antibodies against 4-nonylphenol (NP) in recent years. This work describes the production of new antibodies against NP and also summarizes the characterization of antibodies obtained earlier. Three approaches used to produce alkylphenol-specific antibodies are compared; these are based on: 1. omega-(4-hydroxyphenyl)nonanoic or omega-(4-hydroxyphenyl)heptanoic acid NP derivatives designed to mimic the linear NP isomer; 2. 4-aminophenol, which potentially mimics various substituted phenolic compounds with different side-chain structures at position 4 of the benzene ring; and 3. a mixture of branched NP isomers, conjugated to the carrier protein via a benzene ring by the Mannich reaction, and expected to be the closest mimic of NP structure by preserving its natural alkyl moiety.Fluorescence polarization immunoassays based on different combinations of antibody and labeled antigen for screening detection of NP were developed and structural aspects of assay sensitivity and specificity were investigated. The assays based on the antisera raised against omega-(4-hydroxyphenyl)nonanoic acid and NP conjugate via Mannich reaction are capable of express detection of NP with detection limit of 7 microg mL(-1 )and assay dynamic range of 18-300 microg mL(-1).  相似文献   
4.
In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L−1 to as low as 0.07 μg L−1. The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step.  相似文献   
5.
Milk allergy is the most frequent food allergy in childhood. Even though cases of newly developed milk allergy in adulthood are known, this allergy is less frequent in adults since it is normally outgrown by children during the first years of life. One of the reasons why allergy to cow’s milk shows its highest prevalence in children is its early introduction into the diets of babies when breast feeding is not possible. The major allergens are caseins and β-lactoglobulin, but allergies to other minor proteins (immunoglobulins, bovine serum albumin) have also been reported. Milk allergenicity can be reduced by various treatments (mainly hydrolysis), meaning that formulas based on cow’s milk can often be safely fed to children allergic to milk proteins. Cross-reactivity has been described between different mammalian milks and between milk and meat or animal dander. Cross-contamination can result from inadequate cleaning of industrial equipment and constitutes a hidden danger for allergic subjects who unknowingly ingest milk proteins. Figure Involvement (expressed as percentage of total subjects) of the most abundant milk proteins in the sensitization of 80 children allergic to cow’s milk. The upper panel includes all positive responses, even minor ones; data in the lower panel are restricted to the most severe positive responses (see text for details). SPT, skin prick test; CAP, CAP test; IMM, immunoblotting; alpha-LA, α-lactalbumin; beta-LG, β-lactoglobulin; cas, caseins; BSA, bovine serum albumin  相似文献   
6.
Polycyclic aromatic hydrocarbons (PAHs) are of environmental concern, for instance when found in contaminated soils at sites where industrial activities have occurred. For efficient screening of such soils, the commercially available enzyme-linked immunosorbent assay (ELISA) kit, the PAH RIS soil test, can be used. However, the site-specific performance may vary due to differences in soil properties and contamination profiles. Hence, in this study we have examined various contributing factors to the total ELISA measurements uncertainties. These factors include contributions from co-extracted (non-target) compounds, the extraction efficiency and differences in cross-reactivity among the target analytes. Reference values were obtained through pressurized liquid extraction (PLE) and gas chromatography coupled to mass spectrometry (GC-MS) analysis. The results showed that the ELISA does not seem to respond to non-target compounds in the soil extracts to any large extent. Furthermore, high molecular weight PAHs were found to be more efficiently extracted with PLE than with methanol agitation, which is used for ELISA. If this, and the cross-reactivity of the individual PAHs, were taken into consideration, the ELISA and GC-MS results were in good agreement.  相似文献   
7.
In this study, a panel of haptens was synthesized for immunoconjugate preparation, and several haptens for heterologous tracer conjugates were also prepared. A highly sensitive polyclonal antibody against the organophosphorus insecticide phosmet was obtained and competitive direct enzyme-linked immunosorbent assays (cd-ELISA) for this pesticide were developed. In the cd-ELISA, the limit of detection (IC15) was 0.6 μg kg−1 and the sensitivity (IC50) was 20 μg kg−1. The suitability of the ELISA for pesticide quantification in peach, apple, orange juice, and apple juice was also studied. Good accuracy and precision were obtained with mean recoveries between 78% and 102.3% and mean coefficients of variation below 13.63%. Validation of the ELISA was conducted by high-performance liquid chromatography. The correlation between the data obtained using the microwell assay and the high-performance liquid chromatography was good (R 2 = 0.9849). The developed immunoassay methods were suitable for the rapid quantitative or qualitative determination of phosmet in food samples.  相似文献   
8.
A new polymeric sorbent synthesised by exploiting molecular imprinting technology has been used to selectively extract naphthalene sulfonates (NSs) directly from aqueous samples. In the non-covalent molecular imprinting approach used to prepare this polymer, 1-naphthalene sulfonic acid (1-NS) and 4-vinylpyridine (4-VP) were used as a template molecule and functional monomer, respectively, and both dissolved in a mixture of methanol/water (4:1) as porogen together with the cross-linker ethylene glycol dimethacrylate. The new non-covalent molecularly imprinted polymer (MIP) prepared in aqueous environment was used as a sorbent in solid-phase extraction (SPE) to selectively extract a group of naphthalene mono- and disulfonates. When one litre of a standard aqueous solution, which contained a mixture of eight NSs, was percolated through the SPE cartridge, all the NSs were retained on the MIP because of the cross-reactivity of the polymer. Recoveries were higher than 80% for all the compounds even after a clean-up step with methanol (MeOH). The MIP was also used to analyse water from the Ebro river.  相似文献   
9.
Enzyme-linked immunosorbent assays (ELISAs) are often employed for the control of deoxynivalenol (DON) in barley and other intermediates involved in beer production chain. Because of the occurrence of high levels of DON-3-glucoside (DON-3-Glc) in malt and beer that have been reported for the first time in our earlier study, research focused on the accuracy of DON determination by immunoassays in cereal-based matrices has been initiated. DON-3-Glc was strongly cross-reacting in all examined commercial ELISA test kits (Ridascreen® DON (R-Biopharm), Veratox 5/5 DON® (Neogen Corporation), Deoxynivalenol EIA (Euro-Diagnostica), and AgraQuant® DON Assay 0.25/5.0 Test Kit (Romer Labs). The highest overestimation in beer analysis, up to 1000%, when taking the DON content determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) as a reference method, was obtained by AgraQuant assay. Besides of DON-3-Glc and 3- and 15-acetyldeoxynivalenol (ADONs), also other, not known yet, matrix components contributed to false positive results. Similar phenomenon, although in a lesser extent due to lower content of these substances, was observed for using ELISA in the analysis of wheat. The relationship between a way of sample handling and DON overestimation was demonstrated; higher ELISA response was measured in an aqueous extract compared to that prepared by acetonitrile-water (84:16, v/v). Most of cross-reacting co-extracts were removed by MycoSep™# 226 cartridge, what leads us to the hypothesis on the presence of currently unknown cross-reactive species.  相似文献   
10.
Cyclosporine A is potent immunosuppressive agent characterized by a narrow therapeutic range, inter- and intra-individual variability and a lack of correlation between drug dosage and blood levels. In view of these facts, blood levels of CyA should be routinely monitored to assess organ rejection and toxicity.

We evaluated CyA as well as its metabolites (AM9, AM19, AMl, and AM4N) in whole blood samples from 117 patients using commercially available immunological assays (AxSYM, EMIT, Dimension) and HPLC.

Cross-reactivity of the immunological assays was evaluated using different concentrations of the CyA metabolites (in vitro cross-reactivity) and by statistical analysis of patient data (in vivo cross-reactivity). Cross-reactivity was seen in all immunological assays, with differences in in vitro and in vivo cross-reactivity.

The statistical analysis showed a classical correlation between HPLC and AxSYM of r2 = 0.89, HPLC versus EMIT of r2 = 0.93, and HPLC versus Dimension of r2 = 0.93.

The percentage metabolite cross-reactivity (%) by immunological assays for four metabolites at two concentrations each (250 and 1000 ng ml−1) was lowest with the Dimension assay.

Of the immunological methods examined, the new Dimension for CyA determination can be relied on to produce results comparable to HPLC; other advantages are its simplicity, practicability and ease of handling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号