排序方式: 共有83条查询结果,搜索用时 15 毫秒
1.
2.
A new, highly sensitive, fast responding and stable potentiometric biosensor for creatinine determination is developed. The biosensor is based on an ammonium ion-selective electrode. Creatinine deiminase (EC 3.5.4.21) is chemically immobilized on the surface of the polymeric ion-sensitive membrane in the form of monomolecular layer using a simple, one-step carbodiimide covalent attachment method. The resulting enzyme electrodes are useful for measurement under flow injection analysis (FIA) conditions. The biosensors exhibit excellent operational and storage stability. The enzyme electrodes retain over 70% of initial sensitivity after ten weeks of work under FIA conditions. The storage stability at 4 °C is longer than half a year without loss of sensitivity. Under optimized conditions near 30 samples per hour can be analyzed and the determination range (0.02-20.0 mmol l−1) fully covers creatinine concentrations important from clinical and biomedical point of view. The simple biosensor/FIA system has been successfully used for determination of creatinine in urine, serum and posthemodialysate samples. 相似文献
3.
Summary A high-performance liquid chromatographic method for the simultaneous determination of urinary organic acids and creatinine for following the metabolism of aromatic solvents is reported. After extraction of acidified, filtered urine with diethylether followed by evaporation, the dried residue is dissolved in mobile phase. Hydroxybenzoic acid is used as internal standard. A column of Nucleosil C18 is used with a precolumn of the same material. The mobile phase is acetonitrilephosphate buffer, pH 3.3 (1783). For determination of creatinine the sample is simply diluted 10-fold and the eluate monitored at 215 nm (UV). This technique gives highly reproducible results and is simple, reliable and useful for biological monitoring. 相似文献
4.
5.
Rodríguez Flores J Berzas Nevado JJ Durán Merás I Rodríguez Gómez MJ 《Journal of separation science》2005,28(7):658-664
A capillary zone electrophoresis (CZE) method using a fused-silica capillary (60.2 cm x 75 microm ID) was investigated for the determination of triamterene (TRI), methotrexate (MTX), and creatinine (CREA) in human urine. The separation was performed using a hydrodynamic injection time of 7 s (0.5 psi), a voltage of 25 kV, a capillary temperature of 30 degrees C, and 40 mM phosphoric acid adjusted to pH 2.25 by addition of triethanolamine as separation electrolyte. Under these conditions, analysis takes about 15 min. A linear response over the 0.5-15.0 mg L(-1) concentration range was found for TRI and MTX, and 0.5-80.0 mg L(-1) for CREA. Dilution of the sample (water:urine, 1:1 for TRI and MTX, and 1:25 for CREA determination) was the only step necessary prior to analysis by electrophoresis. The developed method is easy, rapid, and sensitive and has been applied to determine triamterene,methotrexate, and creatinine in urine samples with satisfactory results. 相似文献
6.
Pentacyanoferrate-bound poly(1-vinylimidazole) (PVI[Fe(CN)5]) was selected as a mediator for amperometric creatinine determination based on the reductive H2O2 detection. Creatinine amidohydrolase (CNH), creatine amidohydrolase (CRH), sarcosine oxidase (SOD), peroxidase (POD), and PVI[Fe(CN)5] were crosslinked with poly(ethylene glycol) diglycidyl ether (PEGDGE) on a glassy carbon (GC) electrode for a creatinine biosensor fabrication. Reduction current was monitored at −0.1 V in the presence of creatinine and O2. It is revealed that PVI[Fe(CN)5] is suitable as a mediator for a bioelectrocatalytic reaction of POD, since PVI[Fe(CN)5] neither reacts with reactants nor works as an electron acceptor of SOD. The amounts of PVI[Fe(CN)5], PEGDGE, and enzymes were optimized toward creatinine detection. Nafion as a protecting film successfully prevented the enzyme layer from interferences. The detection limit and linear range in creatinine determination were 12 μM and 12–500 μM (R2 = 0.993), respectively, and the sensitivity was 11 mA cm−2 M−1, which is applicable for urine creatinine tests. The results of the creatinine determination for four urine samples measured with this proposed method were compared with Jaffe method, and a good correlation was obtained between the results. 相似文献
7.
Galina Gayda Nataliya Stasyuk Andriy Zakalskiy Mykhailo Gonchar Evgeny Katz 《Current Opinion in Electrochemistry》2022
Since l-Arginine (Arg) is a semi-essential amino acid for humans, its adequate amount must be consumed in the diet to prevent certain negative consequences related to insufficient synthesis of this amino acid under specific physiological conditions. Arg metabolism results in the production of a biochemically diverse range of such products as urea, some amino acids, creatine, polyamines, nitric oxide, etc. Arg, an important biomarker in clinical diagnostics, is also used for prevention/treatment of different diseases, including cancer and COVID-19. Furthermore, it serves as an indicator of food and beverages quality.A variety of optic and electrochemical methods for Arg determination have already been suggested. The biosensor systems based on the enzymes of Arg metabolism were shown to be the most promising tools for Arg assay. This review focuses on the peculiarities of electrochemical biosensors for Arg assay based on the use of Arg-degrading enzymes and on the analysis of their advantages as compared to other approaches. 相似文献
8.
Creatinine sensor based on a molecularly imprinted polymer-modified hanging mercury drop electrode 总被引:1,自引:0,他引:1
Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4 V versus Ag/AgCl for 120 s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (≤+0.3 V) HMDE. The creatinine was preconcentrated and instantaneously oxidised in MIP layer giving DPCSV response in the concentration range of 0.0025-84.0 μg mL−1 [detection limit (3σ) 1.49 ng mL−1]. The sensor was found to be highly selective for creatinine without any response of interferents viz., NaCl, urea, creatine, glucose, phenylalanine, tyrosine, histidine and cytosine. The non-imprinted polymer-modified electrode did not show linear response to creatinine. The imprinting factor as high as 9.4 implies that the imprinted polymer exclusively acts as a recognition element of creatinine sensor. The proposed procedure can be used to determine creatinine in human blood serum without any preliminary treatment of the sample in an accurate, rapid and simple way. 相似文献
9.
Birgitte Wuyts Dirk Bernard Nele Van Den Noortgate Johan Van De Walle Bruno Van Vlem Rita De Smet Frank De Geeter Raymond Vanholder Jean-Claude Libeer Joris Delanghe 《Accreditation and quality assurance》2004,10(1-2):15-19
When the calibration of a routine measurement procedure is traced back to metrological higher order, a significant discrepancy can occur between the analytical conditions of the routine measurement and the analytical conditions that were used in the clinical studies upon which the decision-making criteria are based. This can lead to serious interpretation errors with possible dramatic consequences for patients. The calibration of the creatinine Jaffé method is an excellent example of the importance of medical traceability. The compensated Jaffé method correlated accurately with the reference method and the compensated Jaffé creatinine clearance (CrCl), Cockroft and Gault and MDRD with the 51Cr EDTA clearance. The Schwartz estimate based upon the compensated Jaffé and enzymatic method overestimated, while uncompensated Jaffé slightly underestimated glomerular filtration rate (GFR). The situation in children is complex since serum creatinine concentrations are much lower in infants, rendering tubular secretion relatively more important. Low-molecular weight proteins have been suggested to replace serum creatinine as a marker for GFR. -trace protein, cystatin C, and 2-microglobulin showed good correlation with GFR. However, care should be taken in patients presenting with some malignant tumors, since significant increases of cystatin C in patients with metastatic melanoma or colorectal cancer has been reported.Presented at the 9th Conference on Quality in the Spotlight, 18-19 March 2004, Antwerp, Belgium 相似文献
10.
Bruno Debus Dmitry Kirsanov Irina Yaroshenko Alla Sidorova Alena Piven Andrey Legin 《Analytica chimica acta》2015
In clinical analysis creatinine is a routine biomarker for the assessment of renal and muscular dysfunctions. Although several techniques have been proposed for a fast and accurate quantification of creatinine in human serum or urine, most of them require expensive or complex apparatus, advanced sample preparation or skilled operators. To circumvent these issues, we propose two home-made platforms based on a CD Spectroscope (CDS) and Computer Screen Photo-assisted Technique (CSPT) for the rapid assessment of creatinine level in human urine. Both systems display a linear range (r2 = 0.9967 and 0.9972, respectively) from 160 μmol L−1 to 1.6 mmol L−1 for standard creatinine solutions (n = 15) with respective detection limits of 89 μmol L−1 and 111 μmol L−1. Good repeatability was observed for intra-day (1.7–2.9%) and inter-day (3.6–6.5%) measurements evaluated on three consecutive days. The performance of CDS and CSPT was also validated in real human urine samples (n = 26) using capillary electrophoresis data as reference. Corresponding Partial Least-Squares (PLS) regression models provided for mean relative errors below 10% in creatinine quantification. 相似文献