全文获取类型
收费全文 | 147篇 |
免费 | 12篇 |
国内免费 | 12篇 |
专业分类
化学 | 127篇 |
综合类 | 2篇 |
物理学 | 42篇 |
出版年
2024年 | 1篇 |
2023年 | 7篇 |
2022年 | 4篇 |
2021年 | 2篇 |
2020年 | 3篇 |
2019年 | 6篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 1篇 |
2015年 | 5篇 |
2014年 | 3篇 |
2013年 | 10篇 |
2012年 | 10篇 |
2011年 | 9篇 |
2010年 | 8篇 |
2009年 | 18篇 |
2008年 | 8篇 |
2007年 | 10篇 |
2006年 | 12篇 |
2005年 | 14篇 |
2004年 | 11篇 |
2003年 | 7篇 |
2002年 | 8篇 |
2001年 | 1篇 |
2000年 | 3篇 |
1999年 | 1篇 |
1998年 | 2篇 |
1997年 | 3篇 |
1993年 | 1篇 |
排序方式: 共有171条查询结果,搜索用时 421 毫秒
1.
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Relative standard deviations of not more than 5.2% were obtained for both peak currents and migration times of DA and CA (n=5). Using standard adding method, DA in tLrine and plasma samples was detected. The recoveries were in the range of 83%—103%. 相似文献
2.
Joon Myong Song 《Analytica chimica acta》2003,487(1):75-82
In this work, a combination of complementary metal-oxide semiconductor (CMOS) microchip system with capillary array electrophoresis (CAE) is demonstrated as a system for optimizing conditions for enzymatic reaction. Dimethylacridinone (DDAO)-phosphate substrate and alkaline phosphatase conjugate were selected for the enzymatic reaction, which was applicable to the enzyme-linked immunosorbent assay (ELISA) technique. Laser-induced fluorometry with a miniature semiconductor laser was used to detect the enzymatic products. The speed of the enzymatic reaction between the DDAO-phosphate and the alkaline phosphatase conjugate was investigated as a function of reaction time. The microchip-CAE detection system could determine the pH condition and the concentration of enzyme that are suitable for rapid and low-cost analysis. This result shows the feasibility of using the microchip-CAE system for application to miniaturized screening systems. 相似文献
3.
4.
Separation of sodium dodecyl sulfate (SDS)-protein complexes is difficult on plastic microchips due to protein adsorption onto the wall. In this paper, we elucidated the reasons for the difficulties in separating SDS-protein complexes on plastic microchips, and we then demonstrated an effective method for separating proteins using polymethyl methacrylate (PMMA) microchips. Separation difficulties were found to be dependent on adsorption of SDS onto the hydrophobic surface of the channel, by which cathodic electroosmotic flow (EOF; reversed flow) was generated. Our developed method effectively utilized the reversed flow from this cathodic EOF as a driving force for sample proteins using permanently uncoated but dynamic SDS-coated PMMA microchips. High-speed (6 s) separation of proteins and peptides up to 116 kDa was successfully achieved using this system. 相似文献
5.
The determination of glucose in microfluidic chips made of glass or PMMA was used as a model for the combination of an enzymatic reaction with the separation of compounds. It was based on the enzymatic oxidation of glucose and the amperometric detection of hydrogen peroxide. Real samples frequently contain compounds, such as ascorbic acid, which may interfere with quantitative glucose determinations. Thus, electrophoretic separation of specific from unspecific signals was envisaged by applying electric fields which are also used to control the flow of liquid via electroosmotic effects. Surface charge densities of the capillaries influence the electroosmotic flow (EOF). They are dependent on the chip material and on the adsorption of components from the background electrolyte. Reversal of the EOF after addition of cetyltrimethylammonium bromide (CTAB) and an increase in EOF after addition of sodium dodecylsulfate (SDS) were observed at lower surfactant concentrations with the PMMA chips rather than with the glass chips. For both chip materials these concentrations were below the critical micelle concentration. Effective separation of H2O2 and ascorbic acid was achieved with low CTAB concentrations, which lead to a reduction, but not to a reversal of the EOF. Reversal of the EOF by higher CTAB concentrations or the increase in cathodic EOF by SDS accelerated ascorbic acid transportation and reduced the differences in migration times. Thus, for the specific determination of glucose, glucose oxidase was added together with low CTAB concentrations to the background electrolyte. This avoided interference from ascorbic acid, and data obtained from the analysis of fruit juices showed a good correlation to data obtained from a reference method. 相似文献
6.
A multi‐channel microchip electrophoresis using a programmed step electric field strength (PSEFS) method was investigated for fast parallel detection of feline panleukopenia virus (FPV) DNA. An expanded laser beam, a 10× objective lens, and a charge‐coupled device camera were used to simultaneously detect the separations in three parallel channels using laser‐induced fluorescence detection. The parallel separations of a 100‐bp DNA ladder were demonstrated on the system using a sieving gel matrix of 0.5% poly(ethylene oxide) (Mr = 8 000 000) in the individual channels. In addition, the PSEFS method was also applied for faster DNA separation without loss of resolving power. A DNA size marker, FPV DNA sample, and a negative control were simultaneously analyzed with single‐run and one‐step detection. The FPV DNA was clearly distinguished within 30 s, which was more than 100 times faster than with conventional slab gel electrophoresis. The proposed multi‐channel microchip electrophoresis with PSEFS was demonstrated to be a simple and powerful diagnostic method to analyze multiple disease‐related DNA fragments in parallel with high speed, throughput, and accuracy. 相似文献
7.
Microfluidic CE (MCE) is an effective solution for rapid and sensitive determination of multiple analytes. Herein, a dynamic coated cyclic olefin copolymer microchip was developed having an on-chip micropump for fluid velocity adjusting in electrophoretic separations. This micropump was fabricated by constructing a polyacrylamide gel membrane at one channel terminal. Once applying electric field across the membrane, a pressure-driven flow generated automatically to balance the electroosmotic flow (EOF) mismatch at the channel-membrane interface. The influence of gel precursor concentration and operating voltages on the fluid velocity was carefully evaluated. Moreover, the highly integration of injection, separation, and pumping units of the MCE system minimized the dead volume and provides satisfied column efficiency. Experiments showed that by adjusting of pumping voltage reduced the fluid velocity by a factor of 6, resulting six- and threefold resolving power enhancements of rhodamine dye mixture and amino acid mixture, respectively. Furthermore, the developed MCE method was applied for rhodamines and amino acids quantitation in food and cosmetics, with standard addition recoveries of 87.3–106.9% and 89.9–117.4%, respectively. These results were also confirmed by standard HPLC method, revealing the application potential in fast and onsite analysis of complex samples. 相似文献
8.
9.
CHEN ZhiFeng GAO YunHua WANG Li CHU XiaoGang Chinese Academy of Inspection Quarantine Beijing China Technical Institute of Physics Chemistry Chinese Academy of Sciences Beijing Beijing Institute of Labour Protection Beijing 《中国科学:化学》2010,(1)
A set of integrated end-column amperometric detection system has been developed,onto which an electrophoresis microchip can be conveniently integrated.Finely machined by a piece of transparent organic glass,the system consists of an electrophoresis microchip platform and an amperometric detection reservoir,in which the microchip can be fixed onto the platform by microchip grooves and with stainless steel fixture.Each detection electrode can be directly fixed in the amperometric detection reservoir by screws... 相似文献
10.