首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   11篇
数学   1篇
物理学   1篇
  2014年   1篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2009年   5篇
  2005年   2篇
  1988年   1篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
Every leading institution and manufacturing company in the world is dealing with some aspects of flexible automation. This is because they have found that designing and making goods and products on order rather than for stock is the key issue in cutting manufacturing costs and lead time, and eventually staying in business in the future. This paper discusses the way in which this above outlined goal can be implemented in the assembly business, as well as giving design rules on how to design flexible assembly and inspection cells and systems. The rules are justified by solid model simulation and the author's industrial and laboratory experience.  相似文献   
2.
Monolithic columns were introduced in the early 1990s and have become increasingly popular as efficient stationary phases for most of the important chromatographic separation modes. Monoliths are functionally distinct from porous particle-based media in their reliance on convective mass transport. This makes resolution and capacity independent of flow rate. Monoliths also lack a void volume. This eliminates eddy dispersion and permits high-resolution separations with extremely short flow paths. The analytical value of these features is the subject of recent reviews. Nowadays, among other types of rigid macroporous monoliths, the polymethacrylate-based materials are the largest and most examined class of these sorbents. In this review, the applications of polymethacrylate-based monolithic columns are summarized for the separation, purification and analysis of low and high molecular mass compounds in the different HPLC formats, including micro- and large-scale HPLC modes.  相似文献   
3.
Essential oil of Thymus capitatus Hoff et Link is analysed by using four techniques: GC/pyrolyse/MS, GC/FID, electronic impact GC/MS (quadripole), and GC/MS (ion trap). Both major and trace components are analysed. The GC/pyrolyse/MS coupling provides reference to the exact mass compositions without any need of the previously purified references, neither for major or trace components. The comparison between this reference analysis and GC/FID shows that the FID response coefficients may vary by a mean 7% from one component to another. As it was expected, quadripole or ion trap response coefficients vary to a much greater extent (a mean 25%), although the two MS techniques response coefficients are first order consistent. We conclude that GC/MS coupling could be used not only as it is usual for reliable identifications, but also for a complete quantitative routine analysis of essential oils. Expected precision could be very similar to GC/FID precision provided correcting species by species the MS analysis by a mean value of the response coefficient measured for the MS 70 eV electronic impact ionisation technologies. The GC/pyrolyse/MS coupling is proposed as a relevant tool for analysing reference samples containing trace natural species that could not be purified.  相似文献   
4.
5.
The objective of this study was to investigate the behavior of large plasmids on the monolithic columns under binding and nonbinding conditions. The pressure drop measurements under nonbinding conditions demonstrated that the flow velocities under which plasmid passing monolith became hindered by the monolithic pore structure depended on the plasmid size as well as on the average monolith pore size; however, they were all very high exceeding the values encountered when applying CIM monolithic columns at their maximal flow rate. The impact of the ligand density and the salt concentration in loading buffer on binding capacity of the monolith for different sized plasmids was examined. For all plasmids the increase of dynamic binding capacity with the increase of salt concentration in the loading solution was observed reaching maximum of 7.1 mg/mL at 0.4M NaCl for 21 kbp, 12.0 mg/mL at 0.4 M NaCl for 39.4 kbp and 8.4 mg/mL at 0.5M NaCl for 62.1 kbp. Analysis of the pressure drop data measured on the monolithic column during plasmid loading revealed different patterns of plasmid binding to the surface, showing "car-parking problem" phenomena under certain conditions. In addition, layer thickness of adsorbed plasmid was estimated and at maximal dynamic binding capacity it matched calculated plasmid radius of gyration. Finally, it was found that the adsorbed plasmid layer acts similarly as the grafted layer responding to changes in solution's ionic strength as well as mobile phase flow rate and that the density of plasmid layer depends on the plasmid size and also loading conditions.  相似文献   
6.
Binding of three different bacteriophages (phages), namely T7, lambda and M13 on methacrylate monoliths was investigated. Phage M13 exhibited the highest dynamic binding capacity of 4.5×10(13) pfu/mL while T7 and lambda showed capacity of 1×10(13) pfu/mL, all corresponding to values of around 1mg/mL. Interestingly, capacity for lambda phage was increased 5-fold by increasing NaCl concentration in a loaded sample from 0 to 0.2M while there was a constant capacity decrease for T7 and M13 phages. Under optimal conditions, recovery for all three phages approached 100%. Measurement of a pressure drop increase during loading enabled estimation of adsorbed phage layer thickness. At a maximal capacity it was calculated to be around 50 nm for T7 phage and 60 nm for lambda phage matching closely capside size thus indicating monolayer adsorption while 80 nm layer thickness was estimated for M13 phage showing its orientation along the pore.  相似文献   
7.
The aim of this study was to develop a chromatographic method, as a substitute for enzyme-linked immunosorbent assays, for the rapid and simultaneous detection of IgG, insulin, and transferrin present in a cell culture medium. Conjoint liquid chromatography (conjoint LC) using monolithic disks was applied for this purpose. An anion-exchange disk was combined with a Protein G affinity disk in a preparative HPLC system. IgG bound to the Protein G disk, whereas transferrin and insulin were captured on the quaternary ammonium (QA) disk. Using this method, it was possible to simultaneously determine the concentrations of IgG, transferrin, and insulin in the cell culture medium. Thus, conjoint LC could be used for the rapid and simultaneous detection of different proteins present in a cell culture medium.  相似文献   
8.
The aim of this work was to develop a trypsin-based micro-immobilized enzyme reactor prepared on a monolithic ethylenediamine BIA Separations CIM (convective interaction media) minidisk. The micro-immobilized enzyme reactor (IMER) was integrated in a liquid chromatography system hyphenated to electrospray ionization tandem mass spectrometry to carry out on-line protein digestion and identification. The performance of this IMER was compared with that obtained using a previously developed bioreactor prepared on a conventional CIM ethylenediamine disk and with that of the commercially available Poroszyme immobilized trypsin cartridge. In this work, we showed how different proteins were identified with good recoveries using a digestion time of 10 min only.  相似文献   
9.
Monoclonal antibodies (MAbs) have diverse applications in diagnostics and therapeutics. The recent advancement in hybridoma technology for large‐scale production of MAbs in bioreactors demands rapid and efficient purification methods. Conventional affinity purification systems have drawbacks of low flow rates and denaturation of antibodies owing to harsh elution conditions. Here, we attempted purification of MAbs by use of a high‐throughput metal–chelate methacrylate monolithic system. Monolithic macroporous convective interaction media–iminodiacetate (CIM‐IDA) disks immobilized with four different metal ions (Cu2+, Ni2+, Zn2+ and Co2+) were used and evaluated for purification of anti‐human serum albumin IgG1 mouse MAbs from cell culture supernatant after precipitation with 50% ammonium sulfate. Elution with 10 mM imidazole in the equilibration buffer (25 mM MMA = MOPS (Morpholino propane sulfonic acid) + MES (Morpholino ethane sulfonic acid) + Acetate + 0.5 M NaCl, pH 7.4) resulted in a purification of 25.7 ± 2.9‐fold and 32.5 ± 2.6‐fold in experiments done using Zn2+ and Co2+ metal ions, respectively. The highest recovery of 85.4 ± 1.0% was obtained with a CIM‐IDA‐Zn(II) column. SDS–PAGE, ELISA and immuno‐blot showed that the antibodies recovered were pure, with high antigen‐binding efficiency. Thus, metal chelate CIM monoliths could be a potential alternative to conventional systems for fast and efficient purification of MAbs from the complex cell culture supernatant. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
10.
Human plasma is an important medical substance and a raw material for production of various therapeutics. During blood sampling, storage and processing, genomic DNA is released into plasma from nucleated blood cells that are damaged in the course of the procedure. In order to determine the concentration of contaminating DNA in plasma, we developed a method for DNA isolation by using anion-exchange chromatography on a BIA Separations CIM (convective interaction media) diethylaminoethyl column. DNA was quantified by SYBR Green based real-time polymerase chain reaction. The concentration of cell-free, non-apoptotic DNA in plasma ranged between 0.06 and 22.5 ng/ml. As substantial volumes of plasma or whole blood are administered directly into the vascular system, a recipient is exposed to high amounts of cell-free DNA, several orders of magnitude higher than the amount found in other biologicals.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号